Although there may be other reasons for using calcium tungstate screens in industrial radiography, they are most usually used to: -Correct Answer Decrease exposure time In film radiography, pentameters are usually placed: -Correct Answer on the source side of the test object The penetrating ability of an x-ray beam is governed by: -Correct Answer Kilovoltage Co-60 used in nondestructive testing emits: -Correct Answer Gamma rays A densitometer is an instrument for measuring: -Correct Answer film density Three liquids which are essential to process an exposed film properly are: -Correct Answer Developer, fixer and water The two most common causes for excessively high-density radiographs are: -Correct Answer overexposure and underdevelopment the time required for one-half of the atoms in a particular sample of radioactive material to disintegrate is called: -Correct Answer a half- life What does the term R/h refer to when speaking of intensity? -Correct Answer Roentgens per hour The ability to detect a small discontinuity or flaw is called: -Correct Answer radiographic sensitivity Movement, geometry, and screen contact are three factors that affect radiographic: -Correct Answer unsharpness The difference between the densities of two areas of a radiograph is called: -Correct Answer radiographic contrast The most widely used unit of measurement for measuring the rate at which the output of a gamma ray source decays is the: -Correct Answer curie Exposure to x-rays or gamma rays will have what effect on the body? -Correct Answer It may have a cumulative effect which must be considered Which dose would be dangerous, if not fatal, if applied to the entire body in a short period of time? A. 1.5 - 15R B. 25 - 70R C. 200 - 800R D. All of the above doses would most likely be fatal -Correct Answer C. 200 - 800 R When doing gamma ray radiography with high- intensity emitters, the sources are best handled: -Correct Answer by remote handling equipment If a film is placed in a developer solution and allowed to develop without any agitation: -Correct Answer There will be a tendency for areas to affect each other The selection of the proper type of film to be used for the x-ray examination of a particular part depends on: -Correct Answer the thickness of the part, the material of the specimen, the voltage range of the available x-ray machine A Co-60 source has a half life of: -Correct Answer 5.3 Years x-ray tube current is controlled by: -Correct Answer the current passing through the filament The voltage and waveform applied to the x-ray tube by a high- voltage transformer primarily determines the: -Correct Answer penetrating ability lead foil in direct contact with x-ray film: -Correct Answer Intensifies the primary radiation more than the scatter radiation Fluorescent intensifying screens are usually mounted in pairs in rigid holders called: -Correct Answer Cassettes Radiographic sensitivity, in the context of the minimum detectable flaw size, depends on: -Correct Answer graininess of the film, the unsharpness of the flaw image in the film and the contrast the flaw image on the film In order to decrease geometric unsharpness: -Correct Answer Radiation should proceed from as small a focal spot as other considerations will allow As the Kilovoltage applied to the x-ray tube is raised: -Correct Answer x-rays of shorter wavelength and more penetrating power are produced In order to increase the intensity of the x-radiation: -Correct Answer the tube current should be increased

Content preview

ASNT


ASNT RT I EXAM STUDY GUIDE
QUESTIONS AND ANSWERS 2025
Although there may be other reasons for using calcium tungstate screens in industrial
radiography, they are most usually used to: -Correct Answer ✔Decrease exposure time

In film radiography, pentrameters are usually placed: -Correct Answer ✔on the source
side of the test object

The penetrating ability of an x-ray beam is governed by: -Correct Answer ✔Kilovoltage

Co-60 used in nondestructive testing emits: -Correct Answer ✔Gamma rays

A densitometer is an instrument for measuring: -Correct Answer ✔film density

Three liquids which are essential to process an exposed film properly are: -Correct
Answer ✔Developer, fixer and water

The two most common causes for excessively high-density radiographs are: -Correct
Answer ✔overexposure and underdevelopment

the time required for one-half of the atoms in a particular sample of radioactive material
to disintegrate is called: -Correct Answer ✔a half- life

What does the term R/h refer to when speaking of intensity? -Correct Answer
✔Roentgens per hour

The ability to detect a small discontinuity or flaw is called: -Correct Answer
✔radiographic sensitivity

Movement, geometry, and screen contact are three factors that affect radiographic: -
Correct Answer ✔unsharpness

The difference between the densities of two areas of a radiograph is called: -Correct
Answer ✔radiographic contrast

The most widely used unit of measurement for measuring the rate at which the output of
a gamma ray source decays is the: -Correct Answer ✔curie

Exposure to x-rays or gamma rays will have what effect on the body? -Correct Answer
✔It may have a cumulative effect which must be considered


1|Page

, ASNT

Which dose would be dangerous, if not fatal, if applied to the entire body in a short
period of time?
A. 1.5 - 15R
B. 25 - 70R
C. 200 - 800R
D. All of the above doses would most likely be fatal -Correct Answer ✔C. 200 - 800 R

When doing gamma ray radiography with high- intensity emitters, the sources are best
handled: -Correct Answer ✔by remote handling equipment

If a film is placed in a developer solution and allowed to develop without any agitation: -
Correct Answer ✔There will be a tendency for areas to affect each other

The selection of the proper type of film to be used for the x-ray examination of a
particular part depends on: -Correct Answer ✔the thickness of the part, the material of
the specimen, the voltage range of the available x-ray machine

A Co-60 source has a half life of: -Correct Answer ✔5.3 Years

x-ray tube current is controlled by: -Correct Answer ✔the current passing through the
filament

The voltage and waveform applied to the x-ray tube by a high- voltage transformer
primarily determines the: -Correct Answer ✔penetrating ability

lead foil in direct contact with x-ray film: -Correct Answer ✔Intensifies the primary
radiation more than the scatter radiation

Fluorescent intensifying screens are usually mounted in pairs in rigid holders called: -
Correct Answer ✔Cassettes

Radiographic sensitivity, in the context of the minimum detectable flaw size, depends
on: -Correct Answer ✔graininess of the film, the unsharpness of the flaw image in the
film and the contrast the flaw image on the film

In order to decrease geometric unsharpness: -Correct Answer ✔Radiation should
proceed from as small a focal spot as other considerations will allow

As the Kilovoltage applied to the x-ray tube is raised: -Correct Answer ✔x-rays of
shorter wavelength and more penetrating power are produced

In order to increase the intensity of the x-radiation: -Correct Answer ✔the tube current
should be increased


2|Page

Document information

Uploaded on
February 18, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PossibleA
3.9
(152)
Sold
1077
Followers
651
Items
14087
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions