Ozone has ____ oxygen atoms.
➢ 3
True or false the majority of the ozone is located in the troposphere
➢ False
How many molecules of ozone can three molecules of chlorine destroy
➢ 300,000
What is the major function of ozone in the stratosphere
➢ Absorb and reflect uv rays from the sun
What is the primary source of Chlorine in the stratosphere
➢ Emissions of refrigerants by human like cfc and hcfc
What molecule destroys the ozone layer
➢ Chlorine
Which of the following are effects of the ozone layer depletion
➢ Decreasing crop yields and threat to wild and marine life
Who does ozone depletion affect
, ➢ People all over the world
After refrigerant is phased out can equipment still contain refrigerant
➢ Yes
After refrigerant is phased out can technicians service equipment containing
that refrigerant
➢ Yes
After being phased out, where can technicians obtain refrigerant to service
equipment that contains that refrigerant?
➢ From recovered or reclaimed refrigerant
Can refrigerant be resold
➢ Yes, but only if it has been reclaimed to AHRI Standard 700 specifications
Equipment has to be certified to epa standards in order to recover which
refrigerants
➢ Cfc hcfc hfc
If you are selling r 22 refrigerant who can you sell to
➢ A technician or business with an epa 608
If you recover r 22 can you use the recovered refrigerant in another device
owned by a different person
➢ Yes but only if it is reclaimed and meets ahri 700 standards
In the United States when we're all CFCs phased out
, ➢ 1995
In the United States when we're r22 r124b phased out
➢ 2020
In the United States when will all HCFCS be phased out
➢ 2030
What records should be kept for r22
➢ Type of refrigerant, dates and quantity of refrigerant
Section 608 of EPA Clean Air Act is
➢ Federal law
State and local regulations
➢ Have to be followed with federal law and may be stricter
The venting prohibition requires that you recover affected refrigerant before
➢ Opening, servicing, disposing equipment
Under section 608 regulations who is responsible for ensuring that all
refrigerant is removed before disposing of equipment that contains refrigerant
➢ final person in the disposal chain
What appliances do section 608 regulations apply to
➢ Freezers
What does snap stand for
Update 2025/2026 With Certified Answers Graded A+
Brand New !!!
_________________________________________________________________
Ozone has ____ oxygen atoms.
➢ 3
True or false the majority of the ozone is located in the troposphere
➢ False
How many molecules of ozone can three molecules of chlorine destroy
➢ 300,000
What is the major function of ozone in the stratosphere
➢ Absorb and reflect uv rays from the sun
What is the primary source of Chlorine in the stratosphere
➢ Emissions of refrigerants by human like cfc and hcfc
What molecule destroys the ozone layer
➢ Chlorine
Which of the following are effects of the ozone layer depletion
➢ Decreasing crop yields and threat to wild and marine life
Who does ozone depletion affect
, ➢ People all over the world
After refrigerant is phased out can equipment still contain refrigerant
➢ Yes
After refrigerant is phased out can technicians service equipment containing
that refrigerant
➢ Yes
After being phased out, where can technicians obtain refrigerant to service
equipment that contains that refrigerant?
➢ From recovered or reclaimed refrigerant
Can refrigerant be resold
➢ Yes, but only if it has been reclaimed to AHRI Standard 700 specifications
Equipment has to be certified to epa standards in order to recover which
refrigerants
➢ Cfc hcfc hfc
If you are selling r 22 refrigerant who can you sell to
➢ A technician or business with an epa 608
If you recover r 22 can you use the recovered refrigerant in another device
owned by a different person
➢ Yes but only if it is reclaimed and meets ahri 700 standards
In the United States when we're all CFCs phased out
, ➢ 1995
In the United States when we're r22 r124b phased out
➢ 2020
In the United States when will all HCFCS be phased out
➢ 2030
What records should be kept for r22
➢ Type of refrigerant, dates and quantity of refrigerant
Section 608 of EPA Clean Air Act is
➢ Federal law
State and local regulations
➢ Have to be followed with federal law and may be stricter
The venting prohibition requires that you recover affected refrigerant before
➢ Opening, servicing, disposing equipment
Under section 608 regulations who is responsible for ensuring that all
refrigerant is removed before disposing of equipment that contains refrigerant
➢ final person in the disposal chain
What appliances do section 608 regulations apply to
➢ Freezers
What does snap stand for