Texas Ext Type B TFM02 Exam
1. A three-dimensional fire often involves static True or False
flammable liquid. true or false
false. 3D fires involve flammable liq-
uid in motion as well as both hori-
zontal and
vertical surfaces.
2. Class A fire extinguisher are ok for wood, paper, some plas-
tics and textiles.
3. Dry chemical stored pressure fire extinguish- should be removed or
ers: replaced at their next 6 year
4. Talking about UL rating, the _____ rating refers B:C
to the amount of sq
5. Class B fire extinguishers cannot handle flam- False
mable liquid
6. employees must be trained in the proper use of CRF29
all portable fire extinguishers according to
7. you need to have portable fire extinguishers monthly
VISUALLY inspected
at least _____ according to 29 CFR 1
8. Class A/B fire extinguishers should NOT be used for fire that in-
volves live
electrical equipment
9. Water or steam fire extinguishers need to be annually
discharged,
disassembled and inspected at least:
, Texas Ext Type B TFM02 Exam
10. An extinguisher weighing over 40 lbs should be 3.5 ft
installed so the top is
11. OSHA specified maximum travel distance to an 50 ft.
extinguisher for Class
B
12. dry chem extinguishers requiring 12 yr hydro- 6 yrs
static test must be emptied for maintenance
procedures ever
13. A rated UL extinguishers = how many gallons of 1.25
water?
14. Class ____ fire extinguishers use electrically C
nonconductive extinguishing
15. Cartridge-operated water-based portable ex- Every 5 years
tinguishers need
hydrostatic testing
16. stored pressure type extinguishers need INTER- never
NAL examination
17. extinguishers weighing 40 lbs or less must be 5 ft above the ground
installed so top of canister is no more than _____
18. class ___ extinguishers are for fires involving K
cooking media
19. OSHA specified max travel distance for Class A 75 ft
is ______
20. C
1. A three-dimensional fire often involves static True or False
flammable liquid. true or false
false. 3D fires involve flammable liq-
uid in motion as well as both hori-
zontal and
vertical surfaces.
2. Class A fire extinguisher are ok for wood, paper, some plas-
tics and textiles.
3. Dry chemical stored pressure fire extinguish- should be removed or
ers: replaced at their next 6 year
4. Talking about UL rating, the _____ rating refers B:C
to the amount of sq
5. Class B fire extinguishers cannot handle flam- False
mable liquid
6. employees must be trained in the proper use of CRF29
all portable fire extinguishers according to
7. you need to have portable fire extinguishers monthly
VISUALLY inspected
at least _____ according to 29 CFR 1
8. Class A/B fire extinguishers should NOT be used for fire that in-
volves live
electrical equipment
9. Water or steam fire extinguishers need to be annually
discharged,
disassembled and inspected at least:
, Texas Ext Type B TFM02 Exam
10. An extinguisher weighing over 40 lbs should be 3.5 ft
installed so the top is
11. OSHA specified maximum travel distance to an 50 ft.
extinguisher for Class
B
12. dry chem extinguishers requiring 12 yr hydro- 6 yrs
static test must be emptied for maintenance
procedures ever
13. A rated UL extinguishers = how many gallons of 1.25
water?
14. Class ____ fire extinguishers use electrically C
nonconductive extinguishing
15. Cartridge-operated water-based portable ex- Every 5 years
tinguishers need
hydrostatic testing
16. stored pressure type extinguishers need INTER- never
NAL examination
17. extinguishers weighing 40 lbs or less must be 5 ft above the ground
installed so top of canister is no more than _____
18. class ___ extinguishers are for fires involving K
cooking media
19. OSHA specified max travel distance for Class A 75 ft
is ______
20. C