Building
& B1
Code,
Study
Residential
Guide –Code
Building
ICC Building
& B1
Code,
Study
Inspector
Residential
Guide Exam
–Code
ICC
Preparation.pdf
Building
& B1 Study
Inspector
Guide Exam
– ICC
Preparation.pdf
Building Inspector Exam Preparation.pdf
Building Code, Residential Code & B1
Study Guide – ICC Building Inspector
Exam Preparation
Guidehttps://www.stuvia.com/dashboard!@_)#*)(@$)($@*($@)($@*_
Building Code, Residential Code
Building
& B1
Code,
Study
Residential
Guide –Code
Building
ICC Building
& B1
Code,
Study
Inspector
Residential
Guide Exam
–Code
ICC
Preparation.pdf
Building
& B1 Study
Inspector
Guide Exam
– ICC
Preparation.pdf
Building Inspector Exam Preparation.pdf
,Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
Terms in this set (273)
Glazing in fixed and operable panels of swinging, hazardous location (R308.4.1)
sliding and bifold doors shall be considered to be
a______
Glazing in an individual fixed or operable panel 9, 18, 36 (R308.4.3)
requires safety glazing if the pane is larger
than_____square feet with a bottom edge less
than____inches above the floor and a top edge greater
than_____inches above the floor and a walking surface
is within 36 inches of the glazing, measure
horizontally.
Glazing where the bottom exposed edge of the 36 (R308.4.6)
glazing is less than_____inches above the plane of the
adjacent walking surface of stairways, landings
between flights of stairs and ramps shall be safety
glazing.
Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
,Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
Glazing adjacent to the landing at the bottom of a 30, 60 (R308.4.7)
stairway where the glazing is less than_____inches
above the landing and within a_____inch horizontal arc
less that 180 degrees from the bottom tread nosing
shall be safety glazing.
Garage floor surfaces shall be of approved ____ Noncombustible (R309.1)
material.
Carports shall be open on not less than_____sides. Two (R309.2)
Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
, Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf
Basements, habitable attics and every sleeping room emergency escape, rescue opening (R310.1)
shall have not less than one operable ____ ____ and ____
____.
Emergency escape and rescue openings shall have 44 (R310.2.3)
the bottom of the clear openings not greater than_____
inches above the floor.
Emergency escape and rescue openings shall have a 5.7 (R310.2.1)
net clear opening of not less than_____square feet.
For emergency escape and rescue openings, the 24, 20 (R310.2.2)
minimum net clear opening height dimension shall
be____ inches. The minimum net clear opening width
dimension shall be _____ inches.
The horizontal area of the area well serving an 9, 36 (R310.4.1)
emergency escape and rescue opening shall not be
less than _____ square feet with a horizontal projection
and width of not less than ____ inches.
Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf Building Code, Residential Code, B1 Study Gudie.pdf