Impairment Coordinator - ANSWER- Person responsible for ensuring the proper safety
precautions are taken when the protection system is placed out of service (designated by the
owner).


How many feet of hose would be found at the standpipe outlet ? - ANSWER- 125 feet



In fire prevention there are three areas to consider: - ANSWER- Education (building tenants)
Engineering (layout, suppression systems etc)
Enforcement(Building codes, Fire codes)


Fire Drill Frequency for Group B - ANSWER- Twice a year



Fire Drill Frequency for Group R1 - ANSWER- Quarterly each year



Refresher training for Group B - ANSWER- 1 hour annually (training)



Refresher Training for Group R1 - ANSWER- 1 hour quarterly on each shift


The fire alarm system on your buildings 4th floor has stop functioning. In this case, the fire alarm
system would be deemed: - ANSWER- out-of-service


It shall be unlawful to transmit unnecessary or unwarranted alarms in any six-month period if the
amount of those alarms is: - ANSWER- three or more


Which of the following statements is accurate ?

,A. Activation of a manual pull box shall not be construed as an unnecessary alarm.


B. Activation of a manual pull box shall not be construed as an unwarranted alarm.


C. Activation of a manual pull box shall not be construed as an unattended alarm.


D. Activation of a manual pull box shall not be construed as a disfunctional alarm. - ANSWER-
A. Activation of a manual pull box shall not be construed as an unnecessary alarm.


5. The fire alarm system on the15th floor is unable to function in conformance with the law. In this
case, the FSD should promptly notify:


A. the tenants occupying the 15th and 16th floors


B. the tenants occupying the 15th, 16th and 17th floors


C. the tenants occupying the 15th and 14th floors


D. the tenants occupying the 15th floor - ANSWER- D. the tenants occupying the 15th floor
(occupants of the affected area).


6. An alarm log book shall be maintained on the premises. In general, where should it be kept ?


A. in the Property Managers Office


B. in the Chief Engineers Office


C. in the Mechanical Equipment Room

,D. at the fire command station - ANSWER- D. at the fire command station


7. Which of the following statements about the Alarm Log Book is incorrect?


A. shall be a bound book (other than spiral bound)


B. all entries shall be made in ink and dated


C. shall be retained for a period of two years from the date of the last entry


D. separate log book shall be kept for each calendar year - ANSWER- C. shall be retained for
a period of two years from the date of the last entry - 3 years not 2.


8. The interior fire alarm pull stations are positioned at the natural exits on each floor of the
building. In larger buildings the fire alarm pull stations must be spaced so that the distance between
stations does not exceed


A. 200 feet


B. 150 feet


C. 300 feet


D. 100 feet - ANSWER- A. 200 feet


9. Interior fire alarm pull stations must be securely mounted to the wall


A. at eye level

, B. between 3.5 and 5 feet above the floor level


C. between 3 and 6 feet above the floor level


D. at various heights depending on the tenancy - ANSWER- B. between 3.5 and 5 feet above
the floor level


10. All fire alarm pull stations must be painted .


A. red with white stripes


B. white with red stripes


C. red


D. white with red lettering - ANSWER- C. red


11. Once activated, a fire alarm system cannot be shut off at the pull station. The alarm must be
shut off at the main control panel by which of the following people?


A. only the Certificate of Fitness holder


B. only a uniformed member of the NYFD


C. the Certificate of Fitness holder or a member of the engineering staff


D. the Certificate of Fitness holder or an FDNY representative - ANSWER- D. the Certificate
of Fitness holder or an FDNY representative

Document information

Uploaded on
February 5, 2025
Number of pages
75
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
LECTLucywanha
5.0
(1)
Sold
1
Followers
0
Items
156
Last sold
10 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions