ICC Complete Study Guide Test. Energized parts operating at a minimum of ________ shall be guarded against accidental contact by people through the use of approved enclosures. - CORRECT ANSWER 60 volts Work space in from to f an electrical panel board shall be a minimum of _____ inches in width, but no less than the width of the panel board. - CORRECT ANSWER 30 inches Where electrical conductors are to be spliced, terminated or connected to fixtures or devices, a minimum length of _____ inches of free conductor shall be provided at each outlet, junction or switch point. 1/1 - CORRECT ANSWER 6 inches Where it is impractical to locate the service head or goose neck above the point of attachment of the service-drop or overhead service conductors to the building, the service head or goose neck shall be located a maximum of _____ inches from the point of attachment. 1/1 12 - CORRECT ANSWER 24 An open service conductor without an overall outer jacket shall have a minimum clearance of ____ from the sides of doors, porches and operable windows. - CORRECT ANSWER 3 feet In all cases, the point of attachment of service-drop conductors to a building shall be a minimum of ____ above finished grade. - CORRECT ANSWER 12 feet A metal underground water pipe used as part of the grounding electrode system shall be in direct contact with the earth for a minimum of _____. - CORRECT ANSWER 10 feet Where used outside, an aluminum or coper-clad aluminum grounding electrode conductor shall be installed a minimum of _____ from the earth. - CORRECT ANSWER 18 Inches A minimum of _____ branch circuit(s) shall be provided for receptacles located in the laundry room and a minimum of _____ branch circuit(s) shall be provided to supply the bathroom receptacle outlet(s). - CORRECT ANSWER one 20 ampere rated, one 20 ampere rated In the calculation of electrical feeder loads, an electric clothes dryer load shall be considered _____ VA for each dryer circuit or the nameplate load of each dryer, whichever is greater. - CORRECT ANSWER 5000 What is the maximum over current-protection-device rating permitted for No. 12 copper conductors? - CORRECT ANSWER 20 amps Electrical panel boards and over current protection devices shall not be located in:___________ - CORRECT ANSWER Clothes closets Where metallic plugs or plates are used with nonmetallic electrical enclosures to close unused openings, they shall be recessed a minimum of _______ inches from the outer surface of the enclosure. - CORRECT ANSWER 1/4 Electrical service disconnecting means shall not be installed in __________. - CORRECT ANSWER Bathroom

Content preview

ICC Complete Study Guide Test.

Energized parts operating at a minimum of ________ shall be guarded against accidental contact by
people through the use of approved enclosures. - CORRECT ANSWER 60 volts



Work space in from to f an electrical panel board shall be a minimum of _____ inches in width, but no
less than the width of the panel board. - CORRECT ANSWER 30 inches



Where electrical conductors are to be spliced, terminated or connected to fixtures or devices, a
minimum length of _____ inches of free conductor shall be provided at each outlet, junction or switch
point.

1/1 - CORRECT ANSWER 6 inches



Where it is impractical to locate the service head or goose neck above the point of attachment of the
service-drop or overhead service conductors to the building, the service head or goose neck shall be
located a maximum of _____ inches from the point of attachment.

1/1

12 - CORRECT ANSWER 24



An open service conductor without an overall outer jacket shall have a minimum clearance of ____ from
the sides of doors, porches and operable windows. - CORRECT ANSWER 3 feet



In all cases, the point of attachment of service-drop conductors to a building shall be a minimum of ____
above finished grade. - CORRECT ANSWER 12 feet



A metal underground water pipe used as part of the grounding electrode system shall be in direct
contact with the earth for a minimum of _____. - CORRECT ANSWER 10 feet



Where used outside, an aluminum or coper-clad aluminum grounding electrode conductor shall be
installed a minimum of _____ from the earth. - CORRECT ANSWER 18 Inches

Document information

Uploaded on
February 4, 2025
Number of pages
4
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ROSEGRADES
3.4
(35)
Sold
234
Followers
87
Items
12142
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions