MRI Physics Final Exam Questions With Correct Answers 100% Verified.

Document preview thumbnail
Preview 2 out of 6 pages

MRI Physics Final Exam Questions With Correct Answers 100% Verified. All the following are artifacts in MRI except - Answerbeam hardening _____ is defined as the strength of the gradient over distance - Answerslew rate .5T is equal to _____ Gauss. - Answer5,000 A FLAIR inversion sequence is utilized to null - AnswerCSF A STIR inversion sequence is utilized to null - Answerfat a double echo, spin echo pulse sequence normally results in ____ - AnswerT2 and proton density weighted an inversion recovery is a pulse sequence that begins with a ____ degree inverting pulse - Answer180 a second (or additional) spin or wobble of the magnetic moment is defined as_____ - Answerprecession hydrogen precesses at approximately ______ MHz/T in a .5T MRI unit - Answer21 the time taken to rephase after the application of the 180 degree RF equals the time to dephase when the - AnswerTAU ______ reflects the relationship balance between spin up and spin down nuclei. - Answernet magnetification vector "active" shielding work to ____ , while passive shielding work to _____ - Answershrink the magnetic field, contain the magnetic field to "null" a signal is to _____ a signal - Answerreduce data points in k-space are converted to frequency amplitude in the frequency domain by a process called - Answerfast fourier transfer which of the following is incorrect? - Answerdata acquired in the central lines of k-space contribute to resolution, while data acquired in the outer lines contribute to _____ extrapolates right side dat

Content preview

©JASONMcCONNELL 2024/2025 ALL RIGHTS RESERVED 1/28/2025.




MRI Physics Final Exam Questions With
Correct Answers 100% Verified.


All the following are artifacts in MRI except - Answer✔beam hardening

_____ is defined as the strength of the gradient over distance - Answer✔slew rate

.5T is equal to _____ Gauss. - Answer✔5,000
A FLAIR inversion sequence is utilized to null - Answer✔CSF

A STIR inversion sequence is utilized to null - Answer✔fat

a double echo, spin echo pulse sequence normally results in ____ - Answer✔T2 and proton
density weighted
an inversion recovery is a pulse sequence that begins with a ____ degree inverting pulse -
Answer✔180
a second (or additional) spin or wobble of the magnetic moment is defined as_____ -
Answer✔precession

hydrogen precesses at approximately ______ MHz/T in a .5T MRI unit - Answer✔21
the time taken to rephase after the application of the 180 degree RF equals the time to dephase
when the - Answer✔TAU

______ reflects the relationship balance between spin up and spin down nuclei. - Answer✔net
magnetification vector
"active" shielding work to ____ , while passive shielding work to _____ - Answer✔shrink the
magnetic field, contain the magnetic field
to "null" a signal is to _____ a signal - Answer✔reduce
data points in k-space are converted to frequency amplitude in the frequency domain by a
process called - Answer✔fast fourier transfer

which of the following is incorrect? - Answer✔data acquired in the central lines of k-space
contribute to resolution, while data acquired in the outer lines contribute to
_____ extrapolates right side data and places it on the left side - Answer✔partial echo imaging

1|Page

, ©JASONMcCONNELL 2024/2025 ALL RIGHTS RESERVED 1/28/2025.


for which of the following is it crucial to have a TR that is shorter than the T1 and T2 times of
the tissue - Answer✔steady state

homogeneity is measured in: - Answer✔ppm
how does increasing the sampling time affect the minimum TE time? - Answer✔increase

If i want to increase image resolution, I would _____ slice thickness - Answer✔decrease
if only a single RF pulse were applied, what flip angle would produce the optimal signal return? -
Answer✔90
if the gyromagnetic ratio of a substance is 2Mhz/ tesla and the magnetic field strength is 10
Telsa, then the - Answer✔20 Mhz

if the matrix is increased, what happens to SNR? - Answer✔decrease
if we increase the NEX from 1 to 4, our scan time will _____ - Answer✔increase by a factor of 4
if you decrease receive bandwidth, you _____ SNR - Answer✔increase

if you increase matrix, you increase resolution and ____ scan time - Answer✔increase
if you increase the matrix size and keep the FOV the same, the pixel size will: -
Answer✔decrease
in a pulse sequence utilizing 2 echoes, the first image is typically a ____ image, while the second
is a - Answer✔proton density
in a time of flight sequence, the tissue is hypointense relative to the flowing blood because of: -
Answer✔saturation effects
in fast spin echo weighting, the _____ encoding slopes are centered on the effective TE selected.
- Answer✔shallow
what is the unit of measurement for the strength of the gradient magnetic field? - Answer✔mT/m
it is recommended that that the general public those persons who have not been properly
screened for the effect - Answer✔25G

matter unaffected by a magnetic field is termed: - Answer✔diamagnetic
_____ define items that have been demonstrated to pose no known hazards in a specific MRI
enviornment - Answer✔MRI conditional
time-vary magnetic fields, caused by switching the gradients on and off can cause all of the
following effects - Answer✔coma
which of the following is NOT a potential biological effect that could occur in a static magnetic
field above 2.0 - Answer✔increased touch sensitivity


2|Page

Document information

Uploaded on
January 28, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StarGuide
3.8
(6)
Sold
22
Followers
0
Items
2586
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions