NOMAD Pro 2 Quiz Latest Update
The smaller diameter cone of the NOMAD Pro 2, combined with the use of DC
power, and primary shielding greatly reduce a patient X-ray exposure. - ✔✔✔-True
X-ray locks in NOMAD Pro 2 automatically engage after 2 hours of inactivity. -
✔✔✔-False
Because NOMAD Pro 2 shielding limits the exposure, it is permissible to have other
people
in the exam room during exposures without any precautions. - ✔✔✔-False
The NOMAD Pro 2 should be routinely cleaned using disinfectant wipes, or some
other non acetone cleaner to maintain cleanliness. - ✔✔✔-True
The backscatter shield is adjustable to accommodate positioning devices and other
special needs but if the backscatter shield is adjusted, additional precautions are
required. - ✔✔✔-True
If the NOMAD Pro 2 has been dropped, it should be returned to Aribex for an
evaluation. - ✔✔✔-True
An exposure can be prematurely terminated for any reason by releasing the trigger
at any time during the exposure. - ✔✔✔-True
The NOMAD Pro 2 should normally be held with two hands for stability whenever
possible. - ✔✔✔-True
The Handset can be left on the Charging Cradle after reaching a full charge without
harming the batteries. - ✔✔✔-True
©®™ Page 1
, NOMAD Pro 2 Quiz Latest Update
The Handset should be detached from the NOMAD Pro 2 at the end of each day's
use. - ✔✔✔-True
Radiation safety requires that we establish an in-house radiation protection
program that complies with all applicable regulations and addresses precautions
for patients and operators who have or may have what medical condition? - ✔✔✔-
Pregnancy
When the NOMAD Pro 2 is powered on and in the settings screen, a single quick
pull of the trigger will enable the device. The green LED will illuminate and the
display will indicate the device is ENABLING X-RAYS and then the ________________
message will appear on the screen (meaning the next trigger will fire X-rays). -
✔✔✔-READY / Green Radiation Icon
When the NOMAD Pro 2 is not in service, it is advisable to ensure that the device is
securely stored and the X-rays are ______ so that unauthorized / unintended use or
damage does not occur. - ✔✔✔-LOCKED
An alarm indicating a partial exposure (when the trigger was not depressed
through the entire timer setting, either on purpose or accidentally) is indicated by
a series of beeps and the ____________ message on the screen until a button is
pressed. - ✔✔✔-INCOMPETE / RED
Do not ____ the NOMAD Pro 2 until the patient and film/ sensor are positioned and
ready to avoid unintended firing of the NOMAD Pro 2. - ✔✔✔-ENABLE / READY
When there is not enough battery charge left to take an exposure, the charge
indicator bars will fade away and the ____ alarm message appears on the screen,
and the NOMAD Pro 2 will not allow an exposure to begin. - ✔✔✔-RECHARGE
HANDSET
If left unused NOMAD Pro 2 will automatically shut down after approximately