Content preview

ICC CALIFORNIA UST INSPECTOR
EXAM



Which00agency00approves00a00site-
specific00variance00which00allows00for00an00alternative00method00of00construction00or00m
onitoring:
a.)00The00Regional00Water00Quality00Board
b.)00The00State00Water00Resources00Control00Board
c.)00The00Department00of00Toxic00Substance00Control
d.)00The00local00agency00-00ans--✔✔a.)00The00Regional00Water00Quality00Board
CCR00Title0023,00Sec002681(a)

The00regulations00to00enforce00compliance00of00underground00storage00tank00systems00i
n00the00state00are00found00in?
a.)00Code00of00Federal00Regulations,004000CFR00Part00281
b.)00California00Code00of00Regulations,00Title0023,00Chapter0016
c.)00Code00of00Federal00Regulations,004000CFR00Part00280
d.)00California00Code00of00Regulations,00Title0023,00Chapter001700-00ans--
✔✔b.)00California00Code00of00Regulations;00Title0023,00Chapter0016

By00definition00an00"underground00storage00tank00system"00includes
a.)00The00tank,00all00connected00piping00and00dispensers
b.)00The00tank,00all00connected00piping,00ancillary00equipment00and00containment00syste
m
c.)00Only00the00tank
d.)00Only00tanks00totally00beneath00the00surface00of00the00ground00-00ans--
✔✔b.)00The00tank,00all00connected00piping,00ancillary00equipment00and00containment00s
ystem

(H&SC,00Sec0025281(z))

The00written00report00submitted00to00the00local00agency00after00an00unauthorized00releas
e00is00required00to00include00the00following00except:
a.)00Description00of00actions00taken00to00stop00the00release
b.)00Cause00of00the00release
c.)00Method00of00disposal00of00released00product

,d.)00Date00on00which00the00release00was00discovered00-00ans--
✔✔b.)00Cause00of00the00release
CCR00Title0023,00Sec002652(c)

An00unauthorized00release00which00does00not00escape00from00secondary00containment0
0only00requires00a00record00on00the00operator's00monitoring00reports00provided:
A.00It00did00not00increase00the00hazard00of00fire
B.00It00did00not00cause00any00deterioration00of00the00secondary00containment
C.00It00was00cleaned00up00within00800hours00of00detection
D.00All00of00the00above00-00ans--✔✔D.00All00of00the00above
H&SC,00Sec0025294

The00annual00monitoring00certification00may00be00performed00by:
A.00A00person00possessing00the00appropriate00contractors00licenses
B.00An00individual00trained00and00certified00by00the00manufacturer00of00the00monitoring00
equipment
C.00A00designated00UST00operator
D.00A00person00who00meets00the00requirements00of00both00a00and00b00-00ans--
✔✔D.00A00person00who00meets00the00requirements00of00both00a00and00b
CCR00Title0023,00Sec002715(i)

When00an00automatic00tank00gauge00is00utilized00for00single-
walled00tank00leak00detection,00it00shall00generate00a00post-
test00hard00copy00data00report00of00the00following00information,00except:
a.)00Liquid00volume
b.)00Fuel00depth
c.)00Outside00air00temperature
d.)00Time00and00date00of00test00-00ans--✔✔c.)00Outside00air00temperature
CCR00Title0023,00Sec002643(b)(1)

If00a00UST00system00is00utilizing00an00overfill00alarm,00the00alarm00must00be00triggered00t
o00alert00the00transfer00operator00when00the00tank00is00no00more00than00___________00f
ull
a.)0085%
b.)0095%
c.)0090%
d.)0080%00-00ans--✔✔c.)0090%

An00automatic00tank00gauge00is00utilized00for00leak00detection00of00the00_____________
_.
a.)00Tank
b.)00Tank00and00Piping
c.)00Piping
d.)00Interstitial00space00-00ans--✔✔a.)00Tank
CCR00Title0023,00Sec002643(b)(1)

,After00completion00of00enhanced00leak00detection00(ELD)00test,00the00ELD00test00results0
0must00be00submitted00to00the00_________________.
a.)00The00local00agency
b.)00The00SWRCB
c.)00Owner00of00the00UST00system
d.)00To00both00the00SWRCB00and00the00local00agency00-00ans--
✔✔d.)00To00both00the00SWRCB00and00the00local00agency
CCR00Title0023,00Sec002644.1(a)(5)

A00permit00to00operate00a00UST00system00must00have00all00of00the00following00listed00on
00the00permit,00EXCEPT:
a.)00The00state00UST00identification00number(s)
b.)00Name00of00the00tank00manufacturer00and00tank00capacity
c.)00Permit00expiration00date
d.)00Monitoring00requirements00-00ans--
✔✔b.)00Name00of00the00tank00manufacturer00and00tank00capacity
CCR00Title0023,00Sec002712(c)

A00temporary00closure00is00appropriate00for00which00of00the00following:
a.)00The00UST00system00is00empty00and00will00be00removed00from00service00indefinitely
b.)00The00UST00system00has00ceased00to00store00hazardous00materials00but00will00be00u
sed00within00the00next001200consecutive00months
c.)00The00UST00system00is00unable00to00meet00compliance00requirements00and00will00be
00removed
d.)00The00UST00system00has00been00red-tagged00-00ans--
✔✔b.)00The00UST00system00has00ceased00to00store00hazardous00materials00but00will00b
e00used00within00the00next001200consecutive00months
CCR00Title0023,00Sec00267100&002670

A00local00agency00determines00that00a00UST00facility00within00the00last00year00had00com
pliance00issues.00Prior00to00issuing00a00new00permit00or00renewal00to00operate00an00UST
00the00local00agency00shall:
a.)00Ask00the00state00to00assist00in00a00joint00inspection
b.)00Request00the00owner/operator00to00submit00a00"Return00to00Compliance"00form.
c.)00Refer00to00a00District00Attorney00Investigator
d.)00Inspect00the00facility00and00determine00compliance00-00ans--
✔✔d.)00Inspect00the00facility00and00determine00compliance
CCR00Title0023,00Sec002712(c)

All00the00following00components00require00third00party00certification,00except:
a.)00Automatic00tank00gauging00systems
b.)00Statistical00inventory00reconciliation00methods
c.)00Spill00Containment00lids
d.)00Liquid00phase00out-of-tank00products00-00ans--✔✔c.)00Spill00Containment00lids

, The00exterior00surface00of00an00underground00storage00tank00must00bear00a00marking00o
r00label00which00shows00the00following00information,00except:
a.)00Design00pressure00in00psig
b.)00Useable00capacity00in00gallons.
c.)00Width00of00the00interstitial00space
d.)00Identity00of00manufacturer00-00ans--✔✔c.)00Width00of00the00interstitial00space
CCR00Title0023,00Sec002631(b)

Which00of00the00following00is00not00a00confined00space:
a.)00A00really00deep00turbine00sump
b.)00A00space00not00designed00for00continuous00employee00occupancy
c.)00An00area00with00limited00access
d.)00An00area00with00limited00ventilation00-00ans--
✔✔d.)00An00area00with00limited00ventilation
CCR00Title008,00Sec005157(b)

A00secondary00containment00system00which00is00not00an00integral00part00of00primary00co
ntainment00shall00be00designed00and00constructed00according00to00an00engineering00sp
ecification00approved00by00a00third00party.00The00secondary00containment00system00shal
l00contain00______________00of00the00volume00of00the00largest00primary00container00wit
hin00it,00in00the00case00of00multiple00primary00containers:
a.)0010000percent
b.)001000percent
c.)0011000percent
d.)0015000percent00-00ans--✔✔d.)0015000percent
CCR00Title0023,00Sec002631(e)(1)(B)

All00the00following00are00approved00overfill00prevention00systems,00except:
a.)00Automatic00shutoff00devices
b.)00Spill00Containers
c.)00Overfill00alarms
d.)00Flapper00valves00-00ans--✔✔b.)00Spill00Containers
CCR00Title0023,00Sec002635(b)(2)

Automatic00line00leak00detectors00shall00be00installed00on00underground00pressurized00pi
ping00with00secondary00containment00and00shall00be00capable00of00detecting00a:
a.)003-gallon00per00hour00leak00rate00at00500psi00within00100hour.
b.)00.1-gallon00per00hour00leak00rate00at00500psi00within00100hour.
c.)003-gallon00per00hour00leak00rate00at001000psi00within00100hour.
d.)00.1-gallon00per00hour00leak00rate00at001000psi00within00100hour.00-00ans--✔✔c.)003-
gallon00per00hour00leak00rate00at001000psi00within00100hour.
CCR00Title0023,00Sec002636(f)(2)(f)(3)00&002643(c)(1)

Individuals00installing00an00Underground00Storage00Tank00System00shall00meet00all00of00
the00following,00except:
a.)00California00Licensed00Tank00Tester

Document information

Uploaded on
January 18, 2025
Number of pages
102
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
favouredone
4.4
(352)
Sold
401
Followers
36
Items
10282
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions