An acceptable reinforcing steel support mechanism for a 24-inch deep footing are? -precast dobie blocks -large,solid pieces of glass -masonry CMU pieces -wooden blocks - correct answer Precast dobie blocks all of the following are true except ? ---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches, unless they are in a member that's permanently cast against earth ---specified concrete cover for headed shear stud reinforcement shall not be less then the cover requirement for the member in which the stud reinforcement is located ---Concrete cover for the flexural members, walls, and compression members with an effective depth of 8-inches can vary -3/8 of an inch ---Concrete cover for members in highly corrosive environments will typically remain the same as cast against earth - correct answer Concrete cover for members in highly corrosive environments will typically remain the same as cast agonist earth As a general rule, Lap splicing bar larger then NO.11 Is? -not permitted -permitted -permitted if bars will be in tension within the structural member -permitted only if bars are within a bundle - correct answer not permitted before new concrete is placed, construction joints must be? -blown free of dirt and debris -wetted ,and standing water removed -sand blasted - treated with a bonding agent - correct answer wetted, and standing water removed grade 60 reinforcing steel has an ultimate strength of? -60,000 -75,000 -90,000 -100,000 - correct answer 90,000 psi The__________may waive requirements for the employment of a special inspection agency if he/she finds that the construction is of minor nature. -building official -engineer or architect of record -owner -all of the above - correct answer building official what is the maximum allowable center to center spacing of spliced bars in a non-contact lap splice for the flexural members? -6 inches -4 inches -8 inches -2 inches - correct answer 6 inches Drilled cast-in place concrete piles that poured with concrete having an f'c of 2500 psi need special inspection? -only when required by the building official -at the engineers discretion -at all times -when poured with concrete having an air entrainment greater then 3% - correct answer at all times The type of portland cement best suited for general use when a moderate heat of hydration is desired is - Type I - Type II - Type III - Type V - correct answer Type II Concrete containing pre-stressed tendons, embedded aluminum, or cast against stay in place galvanized steel forms shall not contain? -lightweight aggregates -pozzolans in excess of 5% -fly ash in excess of 10% -calcium chloride - correct answer calcium chloride billet steel bars are marked by the letter_________on the bars. -S -N -A -W - correct answer S Concrete exposed to water with low permeability requirements shall have a maximum w/c ratio of? -0.4 -0.45 -0.5 -N/A - correct answer 0.5 The following is not allowed in concrete unless it is coated or protected from a reaction with other items in the concrete? -calcium chloride -schedule 20 pipes -galvanized reinforced steel -Aluminum - correct answer Aluminum The last marking on a reinforcing steel bar is - point of origin - size - type of steel - minim

Show more Read less
Institution
RCD
Course
RCD









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
RCD
Course
RCD

Document information

Uploaded on
January 16, 2025
Number of pages
14
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ICC REINFORCED CONCRETE final code
test- 60 questions
An acceptable reinforcing steel support mechanism for a 24-inch deep footing are?

-precast dobie blocks

-large,solid pieces of glass

-masonry CMU pieces

-wooden blocks - correct answer Precast dobie blocks



all of the following are true except ?

---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches, unless they
are in a member that's permanently cast against earth

---specified concrete cover for headed shear stud reinforcement shall not be less then the cover
requirement for the member in which the stud reinforcement is located

---Concrete cover for the flexural members, walls, and compression members with an effective depth of
8-inches can vary -3/8 of an inch

---Concrete cover for members in highly corrosive environments will typically remain the same as cast
against earth - correct answer Concrete cover for members in highly corrosive
environments will typically remain the same as cast agonist earth



As a general rule, Lap splicing bar larger then NO.11 Is?

-not permitted

-permitted

-permitted if bars will be in tension within the structural member

-permitted only if bars are within a bundle - correct answer not permitted



before new concrete is placed, construction joints must be?

-blown free of dirt and debris

-wetted ,and standing water removed

, -sand blasted

- treated with a bonding agent - correct answer wetted, and standing water
removed



grade 60 reinforcing steel has an ultimate strength of?

-60,000

-75,000

-90,000

-100,000 - correct answer 90,000 psi



The__________may waive requirements for the employment of a special inspection agency if he/she
finds that the construction is of minor nature.

-building official

-engineer or architect of record

-owner

-all of the above - correct answer building official



what is the maximum allowable center to center spacing of spliced bars in a non-contact lap splice for
the flexural members?

-6 inches

-4 inches

-8 inches

-2 inches - correct answer 6 inches



Drilled cast-in place concrete piles that poured with concrete having an f'c of 2500 psi need special
inspection?

-only when required by the building official

-at the engineers discretion

-at all times

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
RealGrades Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
170
Member since
2 year
Number of followers
52
Documents
11665
Last sold
4 weeks ago

4.0

26 reviews

5
12
4
5
3
7
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions