TESTED QUESTIONS AND VERIFIED SOLUTIONS| GET IT 100% ACCURATE!!
Raid configuration is a special network of storage devices - answers-SAN
What do dry imagers use to process the latent image on the film - answers-heat
Raid configuration directly attached to a network - answers-NAS
What part of the archive contains the master database of everything contained
within the archive - answers-image manager (controller)
Term used to describe a layer of archive storage - answers-tier
Device used to scan an analog x-ray film into PACS - answers-film digitizer
Part of the archive that contains the physical storage of images within the archive
- answers-image storage (archive storage)
The gold standard of digitizers - answers-laser film digitizer
,2 major types of imagers (film printers). If wet laser imagers use chemicals to
process the latent image on the film, dry laser imagers use - answers-heat
True statements concerning an Application service provider (ASP) - answers-
gives smaller institutions access to a service they could not otherwise afford
assume responsibility for the day to day management of the data archive system
can be used as a disaster recovery mechanism
Organization accredits most hospitals in the United States - answers-TJC
The Joint Commission is a mandatory accreditation required by all hospitals in
order to receive medicare/aid reimbursement - answers-false
Systematic observation and assessment of different aspects of a radiology
department would be what kind of activity - answers-quality assurance (focused
around people and service)
Comprehensive set of activities designed to monitor and maintain systems that
produce a product would be what kind of activity - answers-quality control
(required by law to maintain certain licenses)
Major categories of quality control - answers-error maintenance
,acceptance testing
routine maintenace
Often the weakest link in the digital imaging chain - answers-monitor
Several simple CQI activities need to be monitored in the radiology dept.
Recognition of non diagnostic images is primarily carried out by - answers-the
radiologist
First line of defense in preventing, recognizing, and reporting quality control
issues - answers-the radiologic technologist
Service personnel are responsible for performing the preventative maintenance
(PM) on the digital imaging systems - answers-true
Erasing CR imaging plates and verifying network transmission are considered part
of the radiologists - answers-daily QC duties
Cleaning image receptor, computer display screens, and keyboards are
considered part of the radiologic technologists - answers-weekly QC duties
Reject analysis is considered part of the radiologic technologists - answers-
monthly QC duties
, CR angulation for an AP axial projection (Towne) of the skull when the IOML is
perpendicular to the IR - answers-37 degrees caudal
Where does the CR exit for the parietoacanthial (Waters) projection of the facial
bones - answers-acanthion
For the PA Waters projection the petrous ridges should be projected directly
below the - answers-maxillary sinuses
How much rotation of the head from lateral toward the IR is required for an
axiolateral oblique projection of the mandible in order to demonstrate the mentum
region - answers-45 degrees
Cr exit for a PA projection of the mandible - answers-junction of the lips
Maximum amount of CR angulation that should be used for an axiolateral oblique
projection of the mandible - answers-25 degrees
When obtaining a PA axial (Caldwell) projection of the skull, utilizing a 15 degree
caudal angle, where should the petrous ridges be projected - answers-into the
lower 1/3 of the orbits