Sprinkler Fitter Code 1 Test Exam Question And Correct Answers asterisk (*) - Answer -following the number or letter designating a paragraph indicates that explanatory material on the paragraph can be found in Annex A vertical rule (l) - Answer -changes other than editorial bullet (.) - Answer -where one or more complete paragraphs have been deleted reference ( [ ] ) - Answer -indicates material that has been extracted from another NFPA document, they follow a section of material scope - Answer -the standard should provide the minimum requirements for the design and installation of automatic fire sprinkler systems covered within this standard; these codes are written to protect against a single fire in within the building purpose - Answer -provide a reasonable degree of protection for life and property from fire through standardization of design, installation, and testing requirements for sprinkler systems, including private fire service mains, based on sound engineering principles, test data, and field experience application - Answer -applies to 1) character and adequacy of water supplies, 2) selection of sprinklers, 3) fittings, 4) piping, 5) valves, 6) all materials and accessories including the installation of private service mains; also applies to combined service mains retroactivity - Answer -these standards apply to the time this book was written equivalency - Answer -if other equipment is found to be superior equipment, it should be used, not prevented new technology - Answer -new technology should be used, as long as the safety is not lowered NFPA Publications - Answer -National Fire Protection Association ASCE Publications - Answer -American Society of Civil Engineers approved - Answer -acceptable to authority having jurisdiction Authority Having Jurisdiction - Answer -AHJ, an organization office or individual responsible for enforcing the requirements of code or standard (fire marshal) listed - Answer -equipment, materials or services included in a list published by an organization that is acceptable to the authority shall - Answer -indicates a mandatory requirement should - Answer -indicates a recommendation (advised but not required) standard - Answer -a document, the main text of which contains only the mandatory provisions using the word "shall" ceiling pocket - Answer -an architectural ceiling feature that consists of a bounded area of ceiling located at a higher elevation than the attached lower ceiling flat ceiling - Answer -a continuous ceiling in a single plane horizontal ceiling - Answer -a ceiling with a slope not exceeding 2 in 12 smooth ceiling - Answer -a continuous ceiling free from significant irregularities, lumps or indentations sloped ceiling - Answer -a ceiling with a slope exceeding 2 in 12

Content preview

GM Magazine Sprinklers Test Exam
Question And solution
Primary Magazine, Ammunition Rooms, Ready-Service Magazines - Answer -✔✔Area
where Magazine Sprinklers are required?

To extinguish any fire in the magazine and provide emergency cooling. - Answer -
✔✔The primary purpose of the magazine sprinkler systems.

Salt Water actuated types - Answer -✔✔Magazines and ready-service magazines for
pyrotechnics shall be sprinkled, except for pyrotechnics that
are___________________________

Not Required - Answer -✔✔Sprinkler protection is_______________for ammintions of
40mm and smaller stored in ready-service magazines on or above the weatherdeck.

Detection
Actuation
Sprinkling - Answer -✔✔The Magazine sprinkler systems can be divided
into_________basic functional sections. They are_________________

High Temperature Alarm (F)
Flooding Alarm (FD)
Sprinkler Alarm (FH) - Answer -✔✔The types of alarms or warning devices used for the
magazine sprinkler systems are_______________

It tells you there is a leak by the magazine sprinkler valve, or activation of the magazine
sprinkler system. It usually located in the dry side of the piping about six or eight inches
from the magazine sprinkler valve. - Answer -✔✔What does the Sprinkler Alarm (FH)
do?

This alarm will actuate when the space temperature reaches 105 Degrees - Answer -
✔✔What does the High Temperature (F) do?

It actuates when approximately two inches of water accumulates on deck. As water
accumulates, the float rises, making a set of contacts and sounding an alarm. - Answer
-✔✔What does the Flooding Alarm (FD) do?

Open Loop & Closed Loop - Answer -✔✔The control system is divided into pressure
circuits the________________

Locate
Remote

Document information

Uploaded on
January 14, 2025
Number of pages
2
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
88
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions