Load calculations must be performed in order to determine the _____________ correct answers size of the service and feeders A feeder is defined as all the circuit conductors between the __________ containing fuses or breakers that feed branch circuits correct answers service disconnecting means and the panelboard _______________ are included in the calculated floor area of dwelling units correct answers Open porches A scale ruler is used in correct answers determining the location of outlets The ___________ is NOT an important piece of information to gather before performing load calculations correct answers location of circuit breakers The __________, including the strip heat and blower motor, is necessary information for calculating loads correct answers total volt-ampere load The lighting load for residential dwelling units is _____________ volt-amperes (VA) per square foot correct answers 3 The ____________ for each floor of a one-family dwelling shall be computed using the outside dimensions correct answers floor area _______________ must be included when calculating a dwelling unit service correct answers Small-appliance branch circuits A dwelling unit must have at least ______________ small-appliance branch circuit(s). correct answers 2 Each laundry branch circuit is calculated at _______________ correct answers no less than 1500 volt-amperes Individual household cooking appliances rated more than ___________ watts (volt-amperes) can be derated by using Table 220.55 demand factors ( and all of the appliance notes). correct answers 1750 No derating is allowed when there are only one, two, or three ____________ appliances. correct answers fastened-in place The term _______________ designates utilization equipment commonly built in standardized types and sizes and installed as a unit the perform specific function(s). correct answers appliance Multiplying voltage by amperage produces ____________. correct answers volt-amperes (VA)

Content preview

NEC Final Exam || with 100% Accurate Solutions.
Load calculations must be performed in order to determine the _____________ correct answers
size of the service and feeders

A feeder is defined as all the circuit conductors between the __________ containing fuses or
breakers that feed branch circuits correct answers service disconnecting means and the
panelboard

_______________ are included in the calculated floor area of dwelling units correct answers
Open porches

A scale ruler is used in correct answers determining the location of outlets

The ___________ is NOT an important piece of information to gather before performing load
calculations correct answers location of circuit breakers

The __________, including the strip heat and blower motor, is necessary information for
calculating loads correct answers total volt-ampere load

The lighting load for residential dwelling units is _____________ volt-amperes (VA) per square
foot correct answers 3

The ____________ for each floor of a one-family dwelling shall be computed using the outside
dimensions correct answers floor area

_______________ must be included when calculating a dwelling unit service correct answers
Small-appliance branch circuits

A dwelling unit must have at least ______________ small-appliance branch circuit(s). correct
answers 2

Each laundry branch circuit is calculated at _______________ correct answers no less than 1500
volt-amperes

Individual household cooking appliances rated more than ___________ watts (volt-amperes) can
be derated by using Table 220.55 demand factors ( and all of the appliance notes). correct
answers 1750

No derating is allowed when there are only one, two, or three ____________ appliances. correct
answers fastened-in place

The term _______________ designates utilization equipment commonly built in standardized
types and sizes and installed as a unit the perform specific function(s). correct answers appliance

Multiplying voltage by amperage produces ____________. correct answers volt-amperes (VA)

, A clothes dryer neutral load on a feeder can be calculated at ___________%. correct answers 70

Horsepower ratings must be converted to ______________ before they can be added to the load
calculation form. correct answers volt-amperes (VA)

The smaller of two (or more) ____________ loads can be omitted, as long as they are never
energized simultaneously. correct answers noncoincedent

For the purpose of the standard method load calculation for a one-family dwelling, the terms
neutral and ____________ are synonymous. correct answers grounded

A demand factor of ___________% can be applied to the nameplate rating load of four or more
fastened-in-place appliances. correct answers 75

In outdoor applications, ___________ grounding electrode conductors must not be installed
within 18in (450 mm) of the earth. correct answers aluminum

______________ are not included in calculating receptacle loads for appliances. correct answers
Air-conditioning systems

The exact nameplate rating of the clothes dryer, even if less than ___________ volt-amperes
should be used in load calculations. correct answers 5000

For a service rated 100 through 400 A, the service conductors supplying the entire load
associated with a one-family dwelling shall be permitted to have an ampacity not less
____________ % of the service rating. correct answers 83

The minimum size grounding electrode conductor is ____________ AWG copper ( or 4 AWG
aluminum). correct answers 6

Service-entrance and overhead service conductors shall be arranged so that
_________________. correct answers water shall not enter the service raceway or equipment

The radius of the curve of the inner edge of any bend in service-entrance cable must be at least
___________ times the diameter of the cable. correct answers 5

Type _________ cable can be formed in a gooseneck and taped with a self-sealing weather-
resistant thermoplastic. correct answers SE

Entrance cables must be supported within ____________ of every raceway or enclosure
connection. correct answers 12in. (300 mm)

Although not stipulated in the NEC, some local jurisdictions have adopted _____________ for
service conductors. correct answers specific distance requirements

Document information

Uploaded on
January 12, 2025
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
807
Followers
438
Items
40070
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions