Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 1 out of 3 pages
Exam (elaborations)

NCCER MODULE 26301-20

Document preview thumbnail
Preview 1 out of 3 pages

Branch circuit conductors must have an ampacity rating equal to, or greater than - ANS The noncontinous load plus 125% of the continous load The reciprocal of 125% is equivalent to - ANS 80% of the rating at the overcurrent protective device The square root of 3 - ANS 1.732 A voltage drop exist that exceeds the recommended 3% for branch circuits or 5% for the combination of feeder and branch circuits is caused - ANS When the distance of branch circuit conductors become excessive Nec table 310.16 - ANS List allowable ampacities for insulated conductors rated 0 - 2000v What is the maximum continuous load that may be connected to a 20A, 120v fuse? - ANS 16 amp (80%) Per nec section 220.14(I) - ANS Each receptacle is assigned a value of 180va. The capacity of a 15a 120 volt circuit is 1800va. Nec section 220.52(a) - ANS Requires that the feeder load be computed at 1500va for each required small appliance branch circuit. Nec sections 210.11(c)(2) and 210.52(f) require - ANS The installation of at least one receptacle to supply laundry equipment (1,500va for each laundry circuit) Per NEC section 422.10(a) - ANS 120 gallons or less shall have the branch circuit rated at no less than 125% of the name plate rating of the water heater because it's considered a continuous load Per NEC section 424.22(b) - ANS When space heating equipment utilizes electric resistance heating elements, protection for the resistance elements shall not exceed 60A Per Nec section 440.22(a) - ANS Overcurrent protection devices shall not exceed 175% of the compressor full load current or the branch circuit selection current. Per Nec section 220.14(h)(1) - ANS Each 5' of multi-outlet assembly is considered as one outlets of at least 180va capacity. In locations where many appliances are likely to be used at one time - ANS Each 1' 9; multi-outlets is considered as one outlets of at least 180va capacity Nec section 220.14(g) provides two option for calculating branch circuits - ANS Either using the computed receptacle load of 180va per receptacle or computing the load at 200va per linear foot of show window The actual sign load cannot exceed - ANS 80% of the branch circuit rating Per Nec section 220.14(e) - ANS Outlets for heavy-duty lamp holders are calculated at a minimum of 600va each. Nec table 220.56 list - ANS Demand factors for commercial kitchen equipment Multiplied by 125%, - ANS The resulting ampacity is used to select branch circuit conductors Nec table 430.250 - ANS Is used to determine full load current for three-phase ac motors Branch circuit conductor size is then determined using - ANS NEC table 310.16 Motor short circuit and ground fault protection is sized using - ANS NEC table 430.52 Per Nec section 430.52(c)(1) exception 1 - ANS The next higher standard fuse size is 125a Nec section 630.32(a) - ANS Provides that the rating for the over current protection device shall not exceed 300% of the primary current rating of the welder


Document information

Uploaded on
January 11, 2025
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.39

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocLaura
4.2
(44)
Sold
160
Followers
38
Items
6394
Last sold
3 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.