Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

S12 sprinkler test Exam Questions And Answers

Document preview thumbnail
Preview 2 out of 8 pages

fire department connection - ANS normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve - ANS valve controlling flow to water-based fire protection systems. fire command center - ANS ... MFSPC - ANS ... MLP - ANS ... tags - ANS on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag - ANS no impairment found in entire system- main control valve white tag - ANS fully out of service- place on all fire department connecitons red tag - ANS place on main control valve if FULLY OR PARTIALLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational blue disk - ANS partially out of service- on all fire department connections water storage tank - ANS ... OS & Y valve - ANS indicating type of control valve used for fire sprinkler system deluge valve - ANS water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO deluge sprinkler system - ANS employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached. Early suppresion fast response sprinklers - ANS fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards extra large orifice sprinklers - ANS = or 1 inch less pressure to achieve a given discharge density extended coverage sprinkler - ANS 400 max square feet discharge fire pump - ANS a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected to public water source or tank. provides higher pressure to sprinkler system Glass bulb sprinkler - ANS operated by heat breaking a glass bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for standard response hose valve - ANS valve to additional hose connection hydraulic placard - ANS sign attached to a hydraulically calculated sprinkler system indicating the design density, required gallons per minute and pressure for the system to operate properly hydraulically calculated systems - ANS method of sizing auto sprinkler piping using a prescribed amount of water to be distributed over a specific area. impairment coordinator - ANS in charge of safety during out of service systems intermediate level sprinkler - ANS sprinkler equipped with integral shields to protect the operating elemtn form discharge from sprinklers installed at higher elevations large orifice sprinkler - ANS sprinkler head with orifice size equal or greater than 3/4 and less than 1 inch listed device - ANS A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common. Master Pressure Reducing Valve - ANS A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone. Main Drain - ANS The primary drain connection located on the system riser and also utilized as a flow test connection. Microbiologically Influenced Corrosion (MIC) - ANS Corrosion caused by the presence of microbes in the water supply that over time attack the interior of metallic piping and cause leaks, pitting, and blockages. Old-Style/Conventional Sprinkler - ANS A sprinkler that directs 40% to 60% of the water initially in a downward direction and is designed to be installed with the deflector in either the upright or pendent position. Pendent Sprinkler - ANS A sprinkler designed to be installed in such a way that the water stream is directed downward against the deflector. Pintle Screws - ANS A visual indicating device required for sprinklers manufactured prior to 1999 identifying small orifice sprinklers and large orifice sprinklers where orifice size is different than the nominal thread size of the sprinkler head. Pipe Schedule Systems - ANS A method of sizing piping based upon the number of sprinkler heads and the occupancy of the protected area. Preaction Sprinkler System - ANS A sprinkler system employing automatic sprinklers that are attached to a piping system that contains air that may or may not be under pressure, with a supplemental detection system installed in the same areas as the sprinklers. Pressure Control Valve - ANS A pilot operated pressure reducing valve that may be used with a fire or booster pump designed for the purpose of preventing the incoming water supply pressure from dropping below a set pressure. Pressure-Reducing Valve - ANS A valve designed for the purpose of reducing the downstream water pressure under both flowing (residual) and nonflowing (static) conditions. Pressure Relief Valve - ANS A valve designed for the purpose of releasing excess air or water pressure from the Fire Protection Piping System. Pressure Tank - ANS A tank using air pressure to supplying water for water-based fire protection systems. Tank contents to be maintained at one third air to two thirds water. Quick Response Sprinkler Head - ANS A sprinkler having a fusible link with a response time index (RTI) of 50 or less. Recessed Sprinkler - ANS A sprinkler in which all or part of the body, other than the shank thread, is mounted above the ceiling. Residential Sprinkler - ANS A type of fast response sprinkler that has been specifically tested to enhance survivability in the room of fire origin and listed for use in dwelling units.

Content preview

S12 sprinkler test Exam
Questions And Answers




A
R
U
LA
C
O
D

, fire department connection - ANS normally on exterior of building... FDNY can pump
supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire
extinguishment to supplement existing water supplies.

system control valve - ANS valve controlling flow to water-based fire protection systems.




A
fire command center - ANS ...




R
MFSPC - ANS ...

MLP - ANS ...




U
tags - ANS on closed section valves serving affected areas: area affected, brief description,
occupancy classification, c of f number, estimated time until operational
LA
Green tag - ANS no impairment found in entire system- main control valve

white tag - ANS fully out of service- place on all fire department connecitons

red tag - ANS place on main control valve if FULLY OR PARTIALLY out of service... put
sprinkler company name, date of removal from service and anticipated time to operational
C

blue disk - ANS partially out of service- on all fire department connections

water storage tank - ANS ...
O


OS & Y valve - ANS indicating type of control valve used for fire sprinkler system
D



deluge valve - ANS water supply control valve intended to be operated by actuation of an
automatic detection system that is installed in the same area as the discharge devices.
INTENDED USE IS MANUAL AND AUTO

deluge sprinkler system - ANS employing open sprinklers that are attached to a piping
system that is connected to a water supply through a valve that is opened by the operation of a
detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows
into the piping system and discharges from all sprinklers attached.

Document information

Uploaded on
January 11, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocLaura
4.2
(44)
Sold
160
Followers
38
Items
6394
Last sold
3 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions