Automatic Standpipe System - ANS A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. Auxiliary water supply - ANS supplementary source of water for a standpipe and/or sprinkler system. Control Valve - ANS A valve controlling flow to water-based fire protection systems. Control valves do not include hose valves, inspector's test valves, drain valves, trim valves for dry pipe, pre-action and deluge valves, check valves, or relief valves. Branch line - ANS A pipe system, generally in a horizontal plane, connecting not more than one hose connection with a standpipe. Deficiency - ANS A condition in which the application of the component is not within its designed limits or specifications. Fire Hose Outlet and Release Rack - ANS A water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. Each deluge valve is intended to be capable of automatic and manual operation. Deluge systems are suitable for hazardous occupancies. This includes buildings in which flammable liquids or other hazardous materials are handled or stored. Discharge Device - ANS A device designed to discharge water or foam-water solution in a predetermined, fixed, or adjustable pattern. Examples include, but are not limited to, sprinklers, spray nozzles, and hose nozzles. Dry Standpipe - ANS A standpipe system designed to have piping contain water only when the system is being utilized (No automatic water supply.) Dunnage - ANS Rooftop dunnage involves designing a raised series of beams (usually steel) bearing on posts or bearing walls to support mechanical equipment (usually on a roof top). Fire Department Connection - ANS A connection , normally on the exterior of the building, through which the fire department can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. (Formerly know as Siamese connection.) Fire Hose - ANS A flexible conduit constructed with one or more reinforcements (Jackets), with or without a coating or covering but with an approved nonpermeable lining, or with an inner reinforcement between a protective cover and an approved nonpermeable lining. Fire Hydrant - ANS A valve connection on a water supply system having one or more outlets and that is used to supply hose and fire department pumps with water. Fire Pump - ANS A pump that is a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire standpipe system's water supply and can be powered by electric, diesel or steam. The pump intake is either connected to the public underground water supply piping or a static water source (e.g., tank, reservoir, lake). The pump provides water flow at higher pressure and volume to the standpipe system risers and hose standpipes. Fold - ANS A transverse bend (fold) occurring where the hose is lengthwise double over on itself, as on a pin rack. Gallons per minute (GPM) - ANS typically used to measure fluid flow rate (such as water) or pump capacity. Measurement of water flow rate for a pump or a fire standpipe or sprinkler system. Hose Connection - ANS a combination of equipment provided for connection of a hose to the standpipe system that includes a hose valve with a threaded outlet. Attack Hose - ANS Hose designed to be used by trained fire fighters and fire brigade members to combat fires beyond the incipient stage. Booster Hose - ANS A non-collapsible hose used under positive pressure having an elastomeric or thermoplastic tube, a braided or spiraled reinforcement, and an outer protective cover. Covered Hose - ANS A hose with a jacket covered and lined with a continuous synthetic rubber or plastic. The cover is usually thicker than a coating. Fire Hose - ANS A flexible conduit used to convey water. Hose Valve - ANS The valve to an individual hose connection Occupant Use Hose - ANS Fire hose designed to be used by the building's occupants to fight incipient fires prior to the arrival of trained fire fighters or fire brigade members. Unlined Hose - ANS A hose consisting of only a woven jacket that is usually of linen yarns and is of such quality that the yarn swells when wet, tending to seal the hose. Hose Size - ANS An expression of the internal diameter of the hose. Hose Station - ANS a combination of a hose rack, hose nozzle, hose, and hose connection. In Service - ANS The status of hose stored in a hose house, on a rack or reel, or on a fire apparatus that is available and ready for immediate use at an incident. This doesn't include hose in the storage where it is not readily available to be put into service at an incident. In Storage - ANS A hose that is not readily available for use because it is not at the scene of an incident and not loaded on a vehicle that can transport it to the scene. In Use - ANS Hose being used during fire suppression or during training. Impairment Coordinator - ANS The person responsible for ensuring that proper safety precautions are taken when a fire protection system is placed out of service. The building owner shall assign an impairment coordinator to comply with the requirements of this section. In the absence of a specific designee, the owner shall be considered the impairment coordinator. Labeled - ANS Equipment or materials to which has been attached a label, symbol or other identifying mark or an organization that is acceptable to the authority having jurisdiction and concerned with product evaluation, that maintains periodic inspection of production of labeled equipment or materials , and by whose labeling the manufacturer indicates compliance with appropriate standard or performance in a specified manner.

Content preview

S13 standpipe test Questions
And Answers




A
R
U
LA
C
O
D

, Automatic Standpipe System - ANS A standpipe system that is attached to a water supply
capable of supplying the system demand at all times and that requires no action other than
opening a hose valve to provide water at hose connections.

Auxiliary water supply - ANS supplementary source of water for a standpipe and/or




A
sprinkler system.

Control Valve - ANS A valve controlling flow to water-based fire protection systems. Control




R
valves do not include hose valves, inspector's test valves, drain valves, trim valves for dry pipe,
pre-action and deluge valves, check valves, or relief valves.

Branch line - ANS A pipe system, generally in a horizontal plane, connecting not more than



U
one hose connection with a standpipe.

Deficiency - ANS A condition in which the application of the component is not within its
LA
designed limits or specifications.

Fire Hose Outlet and Release Rack - ANS A water supply control valve intended to be
operated by actuation of an automatic detection system that is installed in the same area as the
discharge devices. Each deluge valve is intended to be capable of automatic and manual
operation. Deluge systems are suitable for hazardous occupancies. This includes buildings in
C

which flammable liquids or other hazardous materials are handled or stored.

Discharge Device - ANS A device designed to discharge water or foam-water solution in a
predetermined, fixed, or adjustable pattern. Examples include, but are not limited to, sprinklers,
O


spray nozzles, and hose nozzles.

Dry Standpipe - ANS A standpipe system designed to have piping contain water only when
D



the system is being utilized (No automatic water supply.)

Dunnage - ANS Rooftop dunnage involves designing a raised series of beams (usually
steel) bearing on posts or bearing walls to support mechanical equipment (usually on a roof
top).

Fire Department Connection - ANS A connection , normally on the exterior of the building,
through which the fire department can pump supplemental water into the sprinkler system,
standpipe, or other system furnishing water for fire extinguishment to
supplement existing water supplies. (Formerly know as Siamese connection.)

Document information

Uploaded on
January 11, 2025
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocLaura
4.2
(44)
Sold
160
Followers
38
Items
6394
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions