Oil Burners license test Questions and Answers 100% Pass The main function of the primary control is: - Locking out on safety in the event of flame failure Power must be provided to an electric blower control board on terminals: - L1 and L2 Once a PSC motor starts - The centrifugal switch turns off the electricity to the capacitor and the start windings Materials who's electrons are so loosely bound that they can be persuaded to move with very little pressure allowing electricity to flow are called - Conductors Oil burners can make CO even when no smoke is present - True Corrosion in the flu pipe may occur if - Flue gas temperature is below the dewpoint and sulfur oxide's combine with water To avoid condensing and the flu pipe and oil fired appliance should have a minimum growth stock temperature of - 350°F All persons assisting and working under the supervision of a person holding a certificate as an oil burner technician must hold current apprentice certificates issued by Department of fire services - True What size pipe is used to cross connect tank outlets piping - 1/2 inch Fuel return piping from an appliance shall - Enter the top of the tank Delayed ignition may be caused by - Unvented pressure regulator 2 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE Installation of oil safety valves and oil pressure reducing valve - Reduces the chance of a return line leak What is an installation - Complete and ready for operation of any oil burning appliance Energizing the ignition circuit during the entire burn cycle reduces - Ignition component life Fuel can be transferred from a tank to an appliance by pressurizing the tank - False What device must be equipped with an air proving switch - Both, draft inducers and power-venters What is a safety control - Any control used to prevent unsafe operation of the controlled equipment A non-resident steam or hot water boiler having a minimum safety relief valve capacity over 200,000 BTU/hr requires certificate of inspection from the department of fire services - Prior to the initial firing, every 3 years after What is the closest distance a supply tank can be to the burner - 5 feet Doing a combustion pretest on and oil burning appliance will not tell you anything this is why they generally are performed - False What is the minimum oil supply line size for a residential system - 3/8 inch A cad cell primary control can lock out safety because - All of the above- dirty, faulty, not sensing flame As heating oil gets colder it's viscosity thickens: - Increas

Content preview

1|Page




Oil Burners license test Questions and
Answers 100% Pass

The main function of the primary control is: - ✔✔Locking out on safety in the event of flame failure


Power must be provided to an electric blower control board on terminals: - ✔✔L1 and L2


Once a PSC motor starts - ✔✔The centrifugal switch turns off the electricity to the capacitor and the start

windings


Materials who's electrons are so loosely bound that they can be persuaded to move with very little

pressure allowing electricity to flow are called - ✔✔Conductors


Oil burners can make CO even when no smoke is present - ✔✔True


Corrosion in the flu pipe may occur if - ✔✔Flue gas temperature is below the dewpoint and sulfur oxide's

combine with water


To avoid condensing and the flu pipe and oil fired appliance should have a minimum growth stock

temperature of - ✔✔350°F


All persons assisting and working under the supervision of a person holding a certificate as an oil burner

technician must hold current apprentice certificates issued by Department of fire services - ✔✔True


What size pipe is used to cross connect tank outlets piping - ✔✔1/2 inch


Fuel return piping from an appliance shall - ✔✔Enter the top of the tank


Delayed ignition may be caused by - ✔✔Unvented pressure regulator



Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

, 2|Page


Installation of oil safety valves and oil pressure reducing valve - ✔✔Reduces the chance of a return line

leak


What is an installation - ✔✔Complete and ready for operation of any oil burning appliance


Energizing the ignition circuit during the entire burn cycle reduces - ✔✔Ignition component life


Fuel can be transferred from a tank to an appliance by pressurizing the tank - ✔✔False


What device must be equipped with an air proving switch - ✔✔Both, draft inducers and power-venters


What is a safety control - ✔✔Any control used to prevent unsafe operation of the controlled equipment


A non-resident steam or hot water boiler having a minimum safety relief valve capacity over 200,000

BTU/hr requires certificate of inspection from the department of fire services - ✔✔Prior to the initial

firing, every 3 years after


What is the closest distance a supply tank can be to the burner - ✔✔5 feet


Doing a combustion pretest on and oil burning appliance will not tell you anything this is why they

generally are performed - ✔✔False


What is the minimum oil supply line size for a residential system - ✔✔3/8 inch


A cad cell primary control can lock out safety because - ✔✔All of the above- dirty, faulty, not sensing

flame


As heating oil gets colder it's viscosity thickens: - ✔✔Increase


The purpose of the oil burner nozzle is to: - ✔✔Atomize, pattern and meter the oil


The primary control must be capable of - ✔✔All of the above


A decrease in CO2 with an increase in excess air will give a drop in stack temperature - ✔✔True




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

Document information

Uploaded on
December 23, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman
3.6
(260)
Sold
1261
Followers
485
Items
43877
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions