Massachusetts Oil burner Practice Questions and Answers 100% Pass When is an automatic draft control not required? - When the equipment is designed to control the draft. Combustion performance testing can indicate: - Improper air oil mixture, too much combustion air, and low pump pressure. If a second oil-burning appliance is installed in a single chimney, you must insure: - Sufficient draft is available for safe operation of all connected equipment. Delayed ignition can be caused by: - Weak ignition transformer You should replace the oil burner nozzle with: - The manufacturers recommended nozzle spray pattern and spray angle. Viscosity problems can be corrected by: - Decreasing the nozzle size and increasing the pump pressure accordingly The minimum operating pressure of an oil pump is: - 100 PSI The cross connection between two supply tanks shall not exceed? - 660 gallons If a stack relay fails you, must? - Replace it with an approved type controller Aquastats are normally found on what type of heating systems? - Hydronic Airstats are found on what type of heating systems? - Forced warm air systems 2 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE Under sized returns on a warm air system can result in what? - Short cycling of the oil burner Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam system? - Some radiators not heating quickly enough Low boiler water temperature in a hydronic hot water system may be caused by? - Undersized oil burner nozzles Delayed opening oil valves are used to? - Allow oil pump to come up to speed If a steam boiler is to be installed with an automatic feeder it must also have: - A backflow prevention device How can a damaged heat exchanger be detected on a forced warm air system? - With a smoke trace candle If a high limit is installed to prevent high boiler water temperature, wha

Content preview

1|Page




Massachusetts Oil burner Practice
Questions and Answers 100% Pass

When is an automatic draft control not required? - ✔✔When the equipment is designed to control the

draft.


Combustion performance testing can indicate: - ✔✔Improper air oil mixture, too much combustion air,

and low pump pressure.


If a second oil-burning appliance is installed in a single chimney, you must insure: - ✔✔Sufficient draft is

available for safe operation of all connected equipment.


Delayed ignition can be caused by: - ✔✔Weak ignition transformer


You should replace the oil burner nozzle with: - ✔✔The manufacturers recommended nozzle spray

pattern and spray angle.


Viscosity problems can be corrected by: - ✔✔Decreasing the nozzle size and increasing the pump

pressure accordingly


The minimum operating pressure of an oil pump is: - ✔✔100 PSI


The cross connection between two supply tanks shall not exceed? - ✔✔660 gallons


If a stack relay fails you, must? - ✔✔Replace it with an approved type controller


Aquastats are normally found on what type of heating systems? - ✔✔Hydronic


Airstats are found on what type of heating systems? - ✔✔Forced warm air systems



Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

, 2|Page


Under sized returns on a warm air system can result in what? - ✔✔Short cycling of the oil burner


Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam system? -

✔✔Some radiators not heating quickly enough


Low boiler water temperature in a hydronic hot water system may be caused by? - ✔✔Undersized oil

burner nozzles


Delayed opening oil valves are used to? - ✔✔Allow oil pump to come up to speed


If a steam boiler is to be installed with an automatic feeder it must also have: - ✔✔A backflow prevention

device


How can a damaged heat exchanger be detected on a forced warm air system? - ✔✔With a smoke trace

candle


If a high limit is installed to prevent high boiler water temperature, what is the function of the low limit? -

✔✔To maintain temperature for domestic hot water


On a steam system, a plugged siphon loop can have what affect on the heating system? - ✔✔Insufficient

heat in the living space


On a triple acting aquastat a minimum of 20 degrees is recommend between the high and low limit, this

will prevent? - ✔✔The boiler going off on high limit before reaching the minimum circulator temperature


An advantage of flame retention burner is - ✔✔Their high static pressure enables boilers and furnaces

with tighter more efficient heat exchange passages


The key final adjustment for most oil burners is - ✔✔Combustion air


Dirt or lint buildup in the bevel of the burner fan blades will - ✔✔Reduce the amount of combustion air




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

Document information

Uploaded on
December 23, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman
3.6
(260)
Sold
1261
Followers
485
Items
43877
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions