Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 16 pages
Exam (elaborations)

NCIDQ Exam | Questions with 100% Correct Answers | Updated &Verified | | 100% Score

Document preview thumbnail
Preview 3 out of 16 pages

NCIDQ Exam | Questions with 100% Correct Answers | Updated &Verified | | 100% Score

Content preview

NCIDQ Exam | Questions with 100% Correct Answers | Updated &Verified | 2024-2025 |
100% Score


Design Theory - ✔✔A way to direct design based on a system of beliefs or philosophy



Programming - ✔✔A process during which info about a problem is collected, analyzed and clearly stated
to provide a basis for design



The 5 Step Process of PROGRAMMAING - ✔✔1) Establishing goals

2) Collecting and analyzing facts

3) Uncovering and testing concepts (programmatic concept)

4) Determining Needs

5) Stating the problem



4 major considerations during programming - ✔✔Form

Function

Economy

Time



Every program should include... - ✔✔- Statement of goals and objectives

- a list of client needs

- a list of spaces and their square footages



Anthropometrics - ✔✔a measurement of the size, proportions, and range of motion of the human body



Ergonomics - ✔✔the study of the relation between human physiology and the physical environment



Human Comfort - ✔✔based on humidity, air movement, air quality, temperature, sound vibration, and
light

,British Thermal Unit (BTU) - ✔✔Amount of heat required to raise 1 pound of water by 1 degree F. In SI
units, this is known as a Joule. Acting over a period of one hour, the SI unit corresponding to BTU/hr is
WATTS



NRTL - ✔✔Nationally Recognized Testing Lab

Underwriter's Lab is one. They pass the following labels:

"listed label": passed the test

"classified label": tested for certain type of use



ASTM E119 - ✔✔Standard Test Methods for Fire Tests of Building Construction ad Materials (evaluates
ability to prevent passage of fire, heat, and hot gasses for a given amount of time



Ratings:

Walls) 1, 2, 3, and 4 hours

Doors) 20, 30, and 45 minutes



NFPA 252 - ✔✔Standard Methods of Fire Tests of Door Assemblies (evaluates ability to resist passage of
flame, heat, and gasses)



ASTM E84 - ✔✔Standard Test Method for Specific Optical Density of Smoke Generated by Solid
Materials



Class: Flame Spread Rating:

A) I 0-25 (most resistant)

B) II 26-75

C) III 76-200



Fire Partition - ✔✔Wall assembly with fire resistance rating of 1 hour. Used in corridor walls, guest
rooms in R-1, R-2, I-1

, Fire Barrier - ✔✔Vertical or horizontal assembly that is fire-resistance rated and is design to restrict
spread of fire, confine it to limited areas, or afford safe passage for egress.

Offers more protection than a fire partition!

MUST be continuous from floor slab to roof above.



Smoke Barrier - ✔✔continuous vertical or horizontal membrane with a minimum fire resistance rating of
1 hour



Accessory Occupancy - ✔✔a space or room that is ancillary to the main occupancy but doesn't exceed
10% of the floor area on the story.

(Example: a small gift shop in a hospital)



Incidental Use Area - ✔✔is ancillary to the main occupancy and has the same classification as the
nearest main occupancy but poses a greater level of risk to that occupancy. It must be separated from
the main occupancy by a fire barrier, be equipped by an automatic sprinkler system, or both.

(Example: a laundry room over 100 SqFt needs both 1 hr rating and sprinklers)



Means of Egress - ✔✔continuous and unobstructed path of vertical and horizontal egress travel from
any point to a public way



Exit Access - ✔✔Portion of the means of egress that leads to the ENTRANCE of an exit .

(does not provide a protected path of travel)



Exit - ✔✔portion of egress that provides a protected path of egress

- MUST have a 1 to 2 hour fire rating

- Travel distance is NOT an issue once the exit has been reached



Exit Discharge - ✔✔the portion of egress between termination of an exit and a public way

(could be interior or exterior)

Document information

Uploaded on
December 8, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$9.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
263
Last sold
-


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions