American National Standards Institute (ANSI) - ✔✔Reviews standard written by organizations such as
ASHRAE, UL and ASTM. Approves thousands of standards, including those for furniture and furnishings.
ASHRAE 62-2001 - ✔✔Sets minimum ventilation requirements to provide a level of indoor air quality
that is safe.
ASTM E119 - ✔✔Assembly Test; Fire is applied to one side of a wall assembly.
ASTM - ✔✔Formerly known as the American Society of Testing and Materials, is a standard writing
organization.
ASTM D2859 - ✔✔Methenamine Pill Test
This pass/fail test measures the sizes of the burn to determine flame resistance of textile floor coverings.
Simply put - does it burn?
ASTM E648 (NFPA 253) - ✔✔Standard Test method for critical radiant flux of floor covering systems
using a radiant heat energy source.
ASTM E662 (NFPA 258) - ✔✔The key thing to remember about this test, is that it measures smoke
density in lab conditions, in a smoke chamber - but can not predict the density of density of smoke
generated by the materials upon exposure to heat and flame under actual fire conditions.
ASTM E84 - ✔✔Also known as the steiner tunnel test, and tests the flame spread rating of Interior
Finishes and Building Materials
BOMA - ✔✔Building Owners and Managers Association
Updated &Verified | 2024-2025 | 100% Score
American National Standards Institute (ANSI) - ✔✔Reviews standard written by organizations such as
ASHRAE, UL and ASTM. Approves thousands of standards, including those for furniture and furnishings.
ASHRAE 62-2001 - ✔✔Sets minimum ventilation requirements to provide a level of indoor air quality
that is safe.
ASTM E119 - ✔✔Assembly Test; Fire is applied to one side of a wall assembly.
ASTM - ✔✔Formerly known as the American Society of Testing and Materials, is a standard writing
organization.
ASTM D2859 - ✔✔Methenamine Pill Test
This pass/fail test measures the sizes of the burn to determine flame resistance of textile floor coverings.
Simply put - does it burn?
ASTM E648 (NFPA 253) - ✔✔Standard Test method for critical radiant flux of floor covering systems
using a radiant heat energy source.
ASTM E662 (NFPA 258) - ✔✔The key thing to remember about this test, is that it measures smoke
density in lab conditions, in a smoke chamber - but can not predict the density of density of smoke
generated by the materials upon exposure to heat and flame under actual fire conditions.
ASTM E84 - ✔✔Also known as the steiner tunnel test, and tests the flame spread rating of Interior
Finishes and Building Materials