• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 5 pages
Exam (elaborations)

API 653 Recertification Quiz With Complete Solution.

Document preview thumbnail
Preview 2 out of 5 pages

API 653 Recertification Quiz With Complete Solution. Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? - ️️️The Shell to bottom joint shall be evaluated for fatigue When removing an existing tank bottom, all arc-gouged areas of the tank shell-to-bottom shall be: - ️️️examined using magnetic particle inspection, and defective areas repaired and re-examined. If RBI assessment has been conducted and the tank has cathodic protection plus a thin-film lining, the maximum inspection interval is: - ️️️14 years When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? - ️️️20,000 lbf/in2

Content preview

API 653 Recertification Quiz



API 653 Recertification Quiz With Complete
Solution.
Per API 653 , with of the following is required when converting an existing tank to operation
at elevated temperatures when it was not originally designed and constructed to API 650,
Appendix M? - ✔️✔️✔️The Shell to bottom joint shall be evaluated for fatigue



When removing an existing tank bottom, all arc-gouged areas of the tank shell-to-bottom
shall be: - ✔️✔️✔️examined using magnetic particle inspection, and defective areas
repaired and re-examined.



If RBI assessment has been conducted and the tank has cathodic protection plus a thin-film
lining, the maximum inspection interval is: - ✔️✔️✔️14 years



When installing a new nozzle in a tank of unknow material, what stress value should be used
to calculate the required shell thickness and reinforcement? - ✔️✔️✔️20,000 lbf/in2



In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet
environment. - ✔️✔️✔️may double with every 18 °F increase in temperature above 77
°F.



Grade 350W/50W is acceptable for tank plate to a maximum thickness of: - ✔️✔️✔
️45mm (1.75in) if fully killed and made to a fine grain practice.



If an RBI assessment has been conducted and the tank has a release prevention barrier, the
maximum initial inspection interval is: - ✔️✔️✔️25 years



As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank
shell below minimum required wall thickness may be evaluated for continued service using
which code? - ✔️✔️✔️API RP 579, section 4, 5 or 6.


API Recertification Quiz Page 1

, API 653 Recertification Quiz




When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches
thick below what minimum metal temperature ?preheat? - ✔️✔️✔️200°F



When evaluated an existing temperature services tank, which has a successful service
history of operation but was not originally designed and constructed to the requirement of
API 650, appendix M, which condition temperature has to be used? - ✔️✔️✔️The max
Operating Temperature shall not exceed the temperature at which the tank has successfully
operated in the pass.



Flange material used for tank repair and alteration shall meet the minimum requirements for
the material specifications according to: - ✔️✔️✔️The as built standard



which is an advantage of thick film UN-REINFORCED linings ? - ✔️✔️✔️Fast curing and
can be put back in service after 24 hours at normal ambient temperature.



The perimeter welds on a welded-on patch plate in the critical zone should be ? - ✔️✔️✔
️Two-pass and examined visually and by either MP or PT.



Existent welds on a tank shell are found to e closer than allowed by API 650 (7th Edition).
Under what conditions can these welds be considered to be acceptable for continued
service? - ✔️✔️✔️Examined by MP inspection with no rejectable indications.



The requirements of which standard shall be considered in the evaluation and alteration to
the tank roof and roof-to-shell junction ? - ✔️✔️✔️Current applicable standard



Welding procedure for ladder and platform assemblies, but not their attachment to the tank?
- ✔️✔️✔️Shall comply with either AWS D1.1, AWS D1.6 or ASME Code Section IX.



In floating roof tanks, shell nozzles without internal piping within operating range of the
floating roof shall be supplied? - ✔️✔️✔️Flush on the inside of the tank.

API Recertification Quiz Page 2

Document information

Uploaded on
December 1, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Succeed
3.9
(281)
Sold
1853
Followers
1499
Items
5742
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions