Where supervised automatic sprinkler systems are required by Code, which standard or code
regulates supervisory attachment installation? - ** VERIFIED ANSWERS **✔✔NFPA 72,
National Fire Alarm Code



A colorless, odorless, electrically non-conductive inert gas that extinguishes fire and forms dry ice
snow when released directly into the atmosphere - ** VERIFIED ANSWERS **✔✔Carbon
dioxide gas



An automatic smoke detector that requires continuous presence of smoke above the alarm threshold
for more than 1 minute before initiating an alarm is said to equipped with which feature below? - **
VERIFIED ANSWERS **✔✔Alarm Verification



Fire Alarm conductors in Class 1, Division 1 locations shall be - ** VERIFIED ANSWERS
**✔✔Multi or single conductor Copper in IMC or GRC



The following wiring methods are not permitted for Fire Alarm conductors installed in Class 1
Division 2 locations - ** VERIFIED ANSWERS **✔✔none of the above, all are acceptable
methods



Fire Alarm equipment shall be durably marked where plainly visible to indicate each circuit - **
VERIFIED ANSWERS **✔✔That is is Power-limited fire alarm circuit



Smoke detectors listed for use in air distribution systems moving more that 2000ft3/min shall be
located - ** VERIFIED ANSWERS **✔✔on the supply air side downstream of the air filters



For smooth ceiling coverage, all points on the ceiling are required to have a detector within a
distance of - ** VERIFIED ANSWERS **✔✔70% of the selected spacing

, Where the light path of a projected beam type detector is abruptly interrupted or obscured - **
VERIFIED ANSWERS **✔✔the unit should initiate a supervisory off normal signal after
verification of blockage



Partitions extending upward to within _____% of the ceiling height shall be considered as affecting
space of smoke detectors - ** VERIFIED ANSWERS **✔✔15%



True or False: for complete coverage detectors would also be required accessible under floor spaces
commonly installed in computer rooms that contain electric wiring - ** VERIFIED ANSWERS
**✔✔True



Where doors are to be closed in response to smoke flowing in either direction on a door where the
lintel is greater than 24" deep, the minimum requirement for the smoke detector installation is - **
VERIFIED ANSWERS **✔✔two ceiling mounted smoke detectors within 5 horizontal feel of
each side of the door opening



In spaces served by air-handling systems, smoke detectors for open area protection should not be
located closer that ______ feet from the air supply or air return diffuser. - ** VERIFIED
ANSWERS **✔✔3 feet



In a corridor 5' wide 130' long and with a smooth ceiling 10' high, what is the maximum distance
between two smoke detectors having a manufactures recommended spacing of 25' - ** VERIFIED
ANSWERS **✔✔35'



When the fire alarm control unit is installed in areas that are not continuously occupied the
following requirements apply - ** VERIFIED ANSWERS **✔✔A smoke detector must be
installed at each control unit(s) location to provide notification of fire at that location



Under quiescent load, the secondary supply for in building fire emergency voice/alarm
communications (EVAC) service shall have sufficient capacity to operate for - ** VERIFIED
ANSWERS **✔✔24 hours followed by 15 minutes at maximum (alarm) load



Under non alarm conditions, the secondary supply of a Fire Alarm System shall be capable of
operating the system for a minimum of - ** VERIFIED ANSWERS **✔✔24 hours followed by 5
minutes at the maximum (alarm) load

Document information

Uploaded on
November 25, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Schoolplug
4.1
(7)
Sold
35
Followers
1
Items
997
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions