All heating, combustion, and cooking equipment shall be provided with insulation or the building construction shall be fire protected, so that during operation the surface of combustible construction materials will not be raised to a temperature higher than ____. - ANS 170 ̊ F Acceptance tests: Boilers shall not be placed in operation upon completion of construction until they have been ____ and an equipment use permit has been issued by the commissioner. - ANS Inspected and tested. Periodic boiler inspections: All boilers shall be inspected at least ____ including chimney connections. - ANS Once a year. Owner's annual statement: The owner of each boiler that is subject to periodic inspections shall file an annual ____ with the commissioner, specifying the location of each boiler and arrangement for inspection. - ANS Written statement. What three things must be tested for any fuel burning and storage installation before the system can be operated? - ANS (1) Tightness of liquid fuel piping. (2) Tightness of fuel oil storage tanks. (3) Tightness of gas distribution piping. What are instruction cards for oil burning systems? - ANS Cards giving complete instructions for care and operation that are permanently located near the equipment. Every oil burning installation that is not fully automatic or requires preheating shall be operated by, or under, the direct supervision of a person holding a ____ issued by the fire commissioner. - ANS COF After any fuel burning equipment repair for which a licensed operator is required, such operator shall also check the repairs and be ____ while the equipment is started. - ANS Present. What is abatement of air contaminants? - ANS Compliance with the air pollution control code. What are the 3 equipment classifications and their temperatures for the products of combustion at the point of leaving the equipment? - ANS (1) Low Temp: 600° F or less. (2) Medium Temp: 600° - 1000° F.

Content preview

K
C
LO
P99/ LOW PSI OIL BURNER
YC
OPERATOR EXAM STUDY
D

GUIDE QUESTIONS WITH
U


CORRECT ANSWERS ALL
ST




VERIFIED BY AN EXPERT A+
GRADED (LATEST UPDATE)

, All heating, combustion, and cooking equipment shall be provided with insulation or the building
construction shall be fire protected, so that during operation the surface of combustible
construction materials will not be raised to a temperature higher than ____. - ANS 170 ̊ F




K
Acceptance tests: Boilers shall not be placed in operation upon completion of construction until
they have been ____ and an equipment use permit has been issued by the commissioner. -
ANS Inspected and tested.




C
Periodic boiler inspections: All boilers shall be inspected at least ____ including chimney
connections. - ANS Once a year.




LO
Owner's annual statement: The owner of each boiler that is subject to periodic inspections shall
file an annual ____ with the commissioner, specifying the location of each boiler and
arrangement for inspection. - ANS Written statement.
YC
What three things must be tested for any fuel burning and storage installation before the system
can be operated? - ANS (1) Tightness of liquid fuel piping.

(2) Tightness of fuel oil storage tanks.

(3) Tightness of gas distribution piping.
D

What are instruction cards for oil burning systems? - ANS Cards giving complete instructions
for care and operation that are permanently located near the equipment.
U


Every oil burning installation that is not fully automatic or requires preheating shall be operated
by, or under, the direct supervision of a person holding a ____ issued by the fire commissioner. -
ST




ANS COF

After any fuel burning equipment repair for which a licensed operator is required, such operator
shall also check the repairs and be ____ while the equipment is started. - ANS Present.

What is abatement of air contaminants? - ANS Compliance with the air pollution control code.

What are the 3 equipment classifications and their temperatures for the products of combustion
at the point of leaving the equipment? - ANS (1) Low Temp: 600° F or less.

(2) Medium Temp: 600° - 1000° F.

Document information

Uploaded on
November 21, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Studyclock
4.2
(234)
Sold
886
Followers
492
Items
8765
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions