• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 30 pages
Exam (elaborations)

Api 653 Exam Prep - Open Book Only

Document preview thumbnail
Preview 3 out of 30 pages

API 653 EXAM PREP - OPEN BOOK ONLY

Content preview

API 653 EXAM PREP - OPEN BOOK
ONLY


*When6using6the6preheat6alternative6weld6method,6the6temperature6shall6be6checked6__
_6to6assure6the6minimum6temperature6is6maintained6during6welding.
A)6one6inch6or6two6times6the6material6thickness6whichever6is6greater,6on6each6side6of6the
6groove.

B)6two6inches6or6two6times6the6material6thickness,6whichever6is6great,6on6each6side6of6th
e6groove
C)6Three6inches6or6three6times6the6material6thickness,6whichever6is6greater,6in6each6side
6of6the6groove

D)6Four6inches6or6four6times6the6material6thickness6whichever6is6greater6on6each6side6of6
the6groove6-6ans--D

*For6a6roof6to6be6considered6as6frangible:
A)6the6top6angle6shall6be6larger6than626X6263/166in
B)6the6top6angle6attachments6weld6shall6me6a6minimum6of63/16"
C)6The6roof6support6members6shall6not6be6attached6tot6he6roof6plate
D)6the6roof6support6members6shall6be6attached6to6the6roof6plate6-6ans--C

*What6are6the6examiner6qualification6for6visual6examination6for6tank6inspection?
A)6Shall6comply6with6ASME6Sect6V,6article69
B)6Shall6have6visual6capable6of6reading6a6standard6Jaeger6J-16chart
C)6Shall6have6biennial6visual6examination6by6a6license6optometrist
D)6There6are6no6requirements6-6ans--D

*Sulfuric6acid6corrosion6can6be6inspected6and6monitored6with:
A)6Shear6wave6ultrasonic6testing
B)6Visual6Inspection
C)6Coupons6and6ER6probes
D)6Wet6fluorescent6magnetic6particle6testing6-6ans--C

*What6is6the6maximum6interpass6temperature6permitted,6in6API6653,6when6using6the6pre
heat6alternative6to6PWHT6welding6method?
A)6600°F
B)6450°F
C)6300°F
D)6800°F6-6ans--A

*Radiographic6examinations6are6required6for6all6of6the6following6except:

,A)6New6and6replaced6shell6insert6plate6and6door6sheet6welds
B)6All6repairs6to6butt-welds6that6are6examined6ultrasonically
C)6New6annular6plate6joints
D)6Shell6Butt-welds6on6reconstructed6tanks6-6ans--B

*For6tanks6constructed6of6material6having6a6yield6strength6equal6to6or6less6than6_____,6it6
may6not6be6necessary6to6raise6all6nozzles,6when6installing6a6new6bottom6in6an6existing6ta
nk,6if6certain6conditions6are6met.
A)6700006psi
B)6600006psi
C)6500006psi
D)6400006psi6-6ans--C

*A6tank,6built6to6the6ninth6edition6of6API6650,6is6to6have6a6new6bottom6installed.6The6instal
lation6will6be6performed6by6slotting6the6shell6and6inserting6the6new6bottom.6The6shell6plat
e6material6is6A-5166Gr.6606and6the6new6shell6to6bottom6weld6will6be6made6using6low-
hydrogen6electrodes.6An6existing6NP26126reinforced6shell6penetration6does6not6meet6the
6minimum6weld6spacing6requirements6of6the6current6API66506edition.6There6is65-

1/26inches6between6the6toe6of6the6shell6to6bottom6weld6and6the6toe6of6reinforcing6plate6fill
et6weld.6The6inspector6should:
A)6Order6the6penetration6raised6to6comply6with6the6current6API66506weld6spacing6require
ments
B)6Order6the6penetration6raised6to6obtain6a6minimum6of666inches6between6the6toe6of6the6
shell6to6bottom6weld6and6the6toe6of6reinforcing6plate6fillet6weld.
C)6Accept6the6penetration6provided6the6penetration6weld6and6the6shell6to6bottom6weld6ar
e6blend6ground6and6examined6by6the6appropr6-6ans--C

*Permanent6attachment6welds,6made6on6A-
5166Gr.6606plate6shall6be6examined6by6which6of6the6following6methods?
A)6Magnetic6particle
B)6Liquid6Penetrant
C)6Either6Magnetic6particle6or6liquid6penetrant
D)6Visual6-6ans--D

*During6an6inspection,6an6inspector6finds6lap-
welded6patch6on6a6tank6shell.6Some6patches6are6thinner6than60.500"6and6others6are6thic
ker6than60.500".6No6patch6plate6is6thinner6that60.1875".6What6should6the6inspector6do?
A)6All6patches6thicker6than60.50"6must6be6removed6and6repairs6made6in6accordance6with
6API6653

B)6Consult6with6engineer6experienced6in6tank6design
C)6all6existing6welded6on6patch6plates6are6acceptable6provided6they6meet6the6size6and6lo
cation6requirements6of6API6653
D)6All6of6the6existing6patch6plates6must6be6removed6and6repairs6made6in6accordance6wit
h6API66536-6ans--C

*in6regards6to6seismic6design,6reconstructed6tanks:

, A)6shall6meet6the6stability6requirments6of6the6current6applicable6standards
B)6Require6the6anchoring6of6the6tank6even6if6not6used6on6the6original6tank
C)6Require6the6installation6of6thickened6bottom6plates6under6the6bottom6shell6course6of6n
ot6existing
D)6Shall6meet6the6stability6requirments6of6the6"as-built"6standard6-6ans--A

*New6welds6(Not6repair6welds)6on6tank6bottom6plates6should6be6examined:
A)6By6vacuum6box6and6tracer6gas
B)6By6magnetic6particle6and6visual
C)6By6visual6only
D)6By6visual6and6vacuum6box6-6ans--D

*API66536requires6the6perimeter6welds6on6the6welded6on6patches6on6the6critical6zone6be:
A)6Two-pass6and6examined6by6visually6and6by6MT6or6PT
B)6Welded6on6pathc6plats6are6not6permitted6for6repairs6in6the6critical6Zone
C)6Single6pass6and6examined6visually6and6by6MT6or6PT
D)6Single6pass6and6examined6visually6and6by6vacuum6box6test6-6ans--A

*The6inspector6finds6a6thin6area6in6the6shell6of6a61506ft.6diameter6riveted6tank.6The6maxi
mum6horizontal6dimension6of6the6thin6area6in6four6inches6and6the6maximum6vertical6dime
nsion6is6one6inch.6The6nearest6edge6of6the6thin6area6is6twelve6inche6from6a6vertical6seam
6and6fifteen6inches6from6horizontal6seam.6it6is6decided6to6make6the6repair6using6a6weld-

on6lap6patch.6Which6is6the6minimum6repair6plate6dimension?
A)6A6lap6patch6is6not6permitted6on6a6riveted6shell
B)6Four6inches
C)6Two6inches
D)6Six6inches6-6ans--B

*New6lap6welded6shell6patch6plate6attachment6welds6shall6be6examined6by6which6of6the6f
ollowing?
A)6Visually6and6by6MT6or6PT
B)6MT6or6PT6only
C)6Vacuum6box6and6solution6film
D)6Visually6only6-6ans--A

*A6locally6thinned6area6is6found6in6a6106year6old6tank.6The6thinned6area6is6located6near6a
6weld6in6the6third6shell6course6from6the6bottom;6206feet6below6the6maximum6liquid6level.6

The6tank6was6built6to6API66506eighth6edition6requirments6with6RT6done6as6required6by6th
e6basic6standard.6The6tank6is62006feet6in6diameter6and6406feet6high.6The6RN6specific6gra
vity6of6the6product6stored6in6the6tank6is60.86.6The6tank6material6allowable6stress6is633,00
06psi.6The6joint6efficiency6is61.0.6What6minimum6thickness6is6required?
A)60.2576inches
B)60.2986inches
C)60.3196inches
D)60.2716inches6-6ans--D

Document information

Uploaded on
November 14, 2024
Number of pages
30
Written in
2024/2025
Type
Exam (elaborations)
Contains
Unknown
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
favouredone
4.4
(352)
Sold
404
Followers
36
Items
10320
Last sold
6 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions