API 653 EXAM PREP CLOSED BOOK
ONLY
API66536defines6a6"Storage6tank6engineer"6as:
A)6A6registered6professional6engineer6in6structural6steel6fabrication
B)6Person6or6organization6who6is6knowledgeable6and6experienced6in6the6engineering6dis
ciplines6associated6with6evaluating6the6integrity6and6reliability6of6aboveground6storage6ta
nks
C)6the6engineering6department6of6a6contractor6who6makes6repairs6to6aboveground6stora
ge6tanks
D)6A6professional6engineer6who6is6also6an6authorized6API66536inspector6-6ans--B
Similar6service6is6means6of6estimating6corrosion6rates6that:
A)6Is6Seldom6used6as6a6means6of6scheduling6internal6inspection6intervals
B)6Ignores6environmental6factors6in6the6determination6of6corrosion6rates
C)6May6be6used6in6addition6to6or6in6lieu6of6actual6measurement6of6corrosion6rates
D)6Is6generally6considered6as6the6best6methodology6for6establishing6the6inspection6interv
als6-6ans--C
Controlled6Deposition6welding6methods,6in6lieu6of6PWHT,6is6limited6to:
A)6P-16materials
B)6P-16and6P-36Materials6only
C)6P-1,6P3,6and6P46materials6only
D)6P-5A6materials6-6ans--C
Inspection6hold6points,6for6tank6reconstruction,6shall6be6designated6by:
A)6The6authorized6inspector
B)6An6engineer6experienced6in6storage6tank6design
C)6Agreement6between6tank6owner/user6and6reconstruction6contractor
D)6Agreement6between6and6engineer6and6the6authorized6-6ans--A
All6repair6and6alteration6work6shall6be6approved6at6all6designated6hold6points6and6after6c
ompletion:
A)6Need6not6be6approved6if6approved6will6delay6work6progress
B)6By6the6repair6organization6of6the6repairs6were6done6according6to6the6specified6repair6
and/or6alteration6procedures
C)6By6the6authorized6inspector6or6experienced6storage6tank6engineer
,D)6By6the6authorized6inspector6only6-6ans--C
Alterations6to6storage6tanks,6which6comply6with6API6650,6must6be6authorized6by:
A)6The6owner/user
B)6The6storage6tank6engineer
C)6The6authorized6inspector
D)6The6repair6organization6-6ans--B
A6record6of6non-essential6variables6used6during6welding6of6the6test6coupon6is:
A)6Optional6on6the6PQR
B)6Optional6on6the6WPS
C)6Required6on6the6PQR
D)6Required6on6the6WPQ6-6ans--A
Cracks6is6the6shell6to6bottom6weld:
A)6Shall6be6evaluated6per6the6"As6built"6Standard
B)6Shall6be6removed
C)6Shall6be6evaluated6on6a6case6by6case6basis
D)6Shall6be6evaluated6per6API65796-6ans--B
What6welding6process6is6most6widely6used6in6the6repair6of6process6equipment?
A)6GMAW
B)6GTAW
C)6SMAW
D)6FCAW6-6ans--C
The6owner6has6decided6to6install6a6new6bottom6in6an6AST.6The6new6bottom6will6be6install
ed6through6existing6tombstone6reinforcing6plates.6One6Method6is6to6remove6the6lower6po
rtion6of6the6reinforcing6plate.6After6the6new6or6replaced6section6is6installed,6the6splice6wel
d6shall:
A)6Visually6examined6only
B)6Magnetic6particle6examined6only
C)6Liquid6penetrate6examined6only
D)6Ultrasonic6shear6wave6examined6only6-6ans--B
Which6of6the6following6is6an6advantage6of6thick6film6reinforced6tank6bottom6lining?
A)6easier6to6apply6than6thin6film
B)6initial6cost6is6typically6less6than6thin6film
C)6Provides6greater6resistance6to6moisture6ingress6permeation
D)6Generally6more6accurate6MFL6floor6scans6-6ans--C
The6purpose6of6reviewing6the6welder6performance6qualification6(WPQ)6is6to:
A)6Verify6that6welder6are6qualified6to6perform6the6welding6given6its6position6and6process
B)6Verify6that6welds6made6in6compliance6with6the6WPS6meet6requirements
C)6Verify6that6the6welding6procedure6specification6can6produce6quality6welds
,D)6Verify6that6welders6are6qualified6to6perform6the6welding,6including6all6essential6and6no
nessential6variables6-6ans--A
The6recommended6type6of6internal6floating6roof6is6the:
A)6Double6Deck
B)6Annular6pontoon
C)6Pan6type
D)6Single6steel6deck6-6ans--B
API6Publication622016on6hot6tapping6and6in-service6welding6covers:
A)6Welding6requirements
B)6technical6aspects
C)6Inspection6requirements
D)6Safety6aspects6-6ans--D
A6repair6is6completed6on6a6nozzle6that6was6originally6postweld6heat6treated(PWHT).6It6ha
s6been6determined6that6PWHT,6of6the6repair,6is6inadvisable.6Who6is6required6to6conduct6
a6metallurgical6review6prior6to6applying6one6of6the6alternative6methods6permitted6in6API6
653?
A)6A6professional6engineer6registered6in6one6or6more6states6or6provinces6of6Canada
B)6A6Storage6tank6engineer
C)6The6Authorized6inspector6responsible6for6the6repair6inspection
D)6A6Metallurgical6engineer6experienced6in6alternative6PWHT6-6ans--B
What6is6another6term6used6for6"Stray6currents"?
A)6Short6circuits
B)6Positive6currents
C)6Impressed6Currents
D)6Interface6currents6-6ans--D
Thick-film6linings6are6commonly6reinforced6with6which6of6the6following?
A)6Sand6and6small6diameter6gravel
B)6Copper6wire,6Stainless6steel6wire,6and6low6alloy6steel6mesh6fabric
C)Chopped6PVC6piping,6copped6ABS6Piping6and6resin6beads
D)6Woven6glass6mat,6chopped6glass6fibers,6and6organic6fibers6-6ans--D
How6and6to6what6extent6are6new6welds6for6tank6bottom6plates6required6to6be6examined?
A)6Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6liquid6penetrate
B)6Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6a6vacuum6box6an
d6a6solution6film,6or6a6tracer6gas6and6detector
C)6Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6visual6examinatio
n
D)Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6wet6fluorescent6m
agnetic6particle6examination6-6ans--B
, According6to6API6653,6no6welding6is6permitted6when6the6temperature6of6the6base6metal6i
s6below6what6value?
A)6Base6metal6temperature6below6-206F
B)6Base6metal6temperature6below606F
C)6Base6metal6temperature6below6206F
D)6Base6metal6temperature6below6306F6-6ans--B
IF6an6AST6is6fabricated6of6material6of6unknown6toughness6and6meets6the6thickness6and6t
emperature6exemption6curve6of6API6653,6the6storage6tank6engineer6must6concur,6in6writi
ng,6with6the6alternative6weld6method6in6lieu6of6PWHT.6Who6is6required6to6authorize6the6a
lternative6and6how6must6this6be6accomplished?
A)6The6owner/operator6in6writing
B)6The6Owner/operator6verbally
C)6The6Authorized6Inspecor6in6writing
D)6The6Authorized6Inspector6verbally6-6ans--A
When6must6an6evaluation,6to6determine6the6suitability6for6continued6use,6be6conducted?
A)6Evaluations6shall6be6conducted6when6a6tank6inspection6reveals6a6change6has6occurre
d6from6the6original6physical6condition6of6a6tank.
B)6Evaluations6shall6be6conducted6at6least6annually
C)6Evaluations6shall6be6conducted6at6an6interval6not6to6exceed6the6calculated6tank6inspe
ction6frequency
D)6Evaluations6shall6be6conducted6once6each6ten6years6of6service6-6ans--A
Inspection6Hold6points6and6minimum6documentation6to6be6submitted6upon6job6completio
n6for6repairs6and6alterations6will6be6designated6by6the:
A)6Owner/User's6engineering6department
B)6Repair6organization
C)6authorized6inspector
D)6Storage6tank6inspector6-6ans--C
In6a6SMAW6electrode,6the6"1"6refers6to:
A)6Electrode6type
B)6Coating6characteristics
C)6Chemical6composition
D)6Welding6position6-6ans--D
NDE6is6defined6as6those6inspection6methods6which6allow6materials6to6be6examined:
A)6without6damaging6the6component
B)6As6an6adjunct6to6visual6examination
C)6without6changing6or6destroying6their6usefulness
D)6Without6using6any6mechanical6force6-6ans--C
If6the6date6of6the6installation6of6a6component6is6unknown,6which6standard6shall6be6consid
ered6as6the6"as-built"6standard?
A)19586edition6of6API612C
ONLY
API66536defines6a6"Storage6tank6engineer"6as:
A)6A6registered6professional6engineer6in6structural6steel6fabrication
B)6Person6or6organization6who6is6knowledgeable6and6experienced6in6the6engineering6dis
ciplines6associated6with6evaluating6the6integrity6and6reliability6of6aboveground6storage6ta
nks
C)6the6engineering6department6of6a6contractor6who6makes6repairs6to6aboveground6stora
ge6tanks
D)6A6professional6engineer6who6is6also6an6authorized6API66536inspector6-6ans--B
Similar6service6is6means6of6estimating6corrosion6rates6that:
A)6Is6Seldom6used6as6a6means6of6scheduling6internal6inspection6intervals
B)6Ignores6environmental6factors6in6the6determination6of6corrosion6rates
C)6May6be6used6in6addition6to6or6in6lieu6of6actual6measurement6of6corrosion6rates
D)6Is6generally6considered6as6the6best6methodology6for6establishing6the6inspection6interv
als6-6ans--C
Controlled6Deposition6welding6methods,6in6lieu6of6PWHT,6is6limited6to:
A)6P-16materials
B)6P-16and6P-36Materials6only
C)6P-1,6P3,6and6P46materials6only
D)6P-5A6materials6-6ans--C
Inspection6hold6points,6for6tank6reconstruction,6shall6be6designated6by:
A)6The6authorized6inspector
B)6An6engineer6experienced6in6storage6tank6design
C)6Agreement6between6tank6owner/user6and6reconstruction6contractor
D)6Agreement6between6and6engineer6and6the6authorized6-6ans--A
All6repair6and6alteration6work6shall6be6approved6at6all6designated6hold6points6and6after6c
ompletion:
A)6Need6not6be6approved6if6approved6will6delay6work6progress
B)6By6the6repair6organization6of6the6repairs6were6done6according6to6the6specified6repair6
and/or6alteration6procedures
C)6By6the6authorized6inspector6or6experienced6storage6tank6engineer
,D)6By6the6authorized6inspector6only6-6ans--C
Alterations6to6storage6tanks,6which6comply6with6API6650,6must6be6authorized6by:
A)6The6owner/user
B)6The6storage6tank6engineer
C)6The6authorized6inspector
D)6The6repair6organization6-6ans--B
A6record6of6non-essential6variables6used6during6welding6of6the6test6coupon6is:
A)6Optional6on6the6PQR
B)6Optional6on6the6WPS
C)6Required6on6the6PQR
D)6Required6on6the6WPQ6-6ans--A
Cracks6is6the6shell6to6bottom6weld:
A)6Shall6be6evaluated6per6the6"As6built"6Standard
B)6Shall6be6removed
C)6Shall6be6evaluated6on6a6case6by6case6basis
D)6Shall6be6evaluated6per6API65796-6ans--B
What6welding6process6is6most6widely6used6in6the6repair6of6process6equipment?
A)6GMAW
B)6GTAW
C)6SMAW
D)6FCAW6-6ans--C
The6owner6has6decided6to6install6a6new6bottom6in6an6AST.6The6new6bottom6will6be6install
ed6through6existing6tombstone6reinforcing6plates.6One6Method6is6to6remove6the6lower6po
rtion6of6the6reinforcing6plate.6After6the6new6or6replaced6section6is6installed,6the6splice6wel
d6shall:
A)6Visually6examined6only
B)6Magnetic6particle6examined6only
C)6Liquid6penetrate6examined6only
D)6Ultrasonic6shear6wave6examined6only6-6ans--B
Which6of6the6following6is6an6advantage6of6thick6film6reinforced6tank6bottom6lining?
A)6easier6to6apply6than6thin6film
B)6initial6cost6is6typically6less6than6thin6film
C)6Provides6greater6resistance6to6moisture6ingress6permeation
D)6Generally6more6accurate6MFL6floor6scans6-6ans--C
The6purpose6of6reviewing6the6welder6performance6qualification6(WPQ)6is6to:
A)6Verify6that6welder6are6qualified6to6perform6the6welding6given6its6position6and6process
B)6Verify6that6welds6made6in6compliance6with6the6WPS6meet6requirements
C)6Verify6that6the6welding6procedure6specification6can6produce6quality6welds
,D)6Verify6that6welders6are6qualified6to6perform6the6welding,6including6all6essential6and6no
nessential6variables6-6ans--A
The6recommended6type6of6internal6floating6roof6is6the:
A)6Double6Deck
B)6Annular6pontoon
C)6Pan6type
D)6Single6steel6deck6-6ans--B
API6Publication622016on6hot6tapping6and6in-service6welding6covers:
A)6Welding6requirements
B)6technical6aspects
C)6Inspection6requirements
D)6Safety6aspects6-6ans--D
A6repair6is6completed6on6a6nozzle6that6was6originally6postweld6heat6treated(PWHT).6It6ha
s6been6determined6that6PWHT,6of6the6repair,6is6inadvisable.6Who6is6required6to6conduct6
a6metallurgical6review6prior6to6applying6one6of6the6alternative6methods6permitted6in6API6
653?
A)6A6professional6engineer6registered6in6one6or6more6states6or6provinces6of6Canada
B)6A6Storage6tank6engineer
C)6The6Authorized6inspector6responsible6for6the6repair6inspection
D)6A6Metallurgical6engineer6experienced6in6alternative6PWHT6-6ans--B
What6is6another6term6used6for6"Stray6currents"?
A)6Short6circuits
B)6Positive6currents
C)6Impressed6Currents
D)6Interface6currents6-6ans--D
Thick-film6linings6are6commonly6reinforced6with6which6of6the6following?
A)6Sand6and6small6diameter6gravel
B)6Copper6wire,6Stainless6steel6wire,6and6low6alloy6steel6mesh6fabric
C)Chopped6PVC6piping,6copped6ABS6Piping6and6resin6beads
D)6Woven6glass6mat,6chopped6glass6fibers,6and6organic6fibers6-6ans--D
How6and6to6what6extent6are6new6welds6for6tank6bottom6plates6required6to6be6examined?
A)6Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6liquid6penetrate
B)6Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6a6vacuum6box6an
d6a6solution6film,6or6a6tracer6gas6and6detector
C)6Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6visual6examinatio
n
D)Newly6welded6bottom6joints6shall6be6tested6their6entire6length6using6wet6fluorescent6m
agnetic6particle6examination6-6ans--B
, According6to6API6653,6no6welding6is6permitted6when6the6temperature6of6the6base6metal6i
s6below6what6value?
A)6Base6metal6temperature6below6-206F
B)6Base6metal6temperature6below606F
C)6Base6metal6temperature6below6206F
D)6Base6metal6temperature6below6306F6-6ans--B
IF6an6AST6is6fabricated6of6material6of6unknown6toughness6and6meets6the6thickness6and6t
emperature6exemption6curve6of6API6653,6the6storage6tank6engineer6must6concur,6in6writi
ng,6with6the6alternative6weld6method6in6lieu6of6PWHT.6Who6is6required6to6authorize6the6a
lternative6and6how6must6this6be6accomplished?
A)6The6owner/operator6in6writing
B)6The6Owner/operator6verbally
C)6The6Authorized6Inspecor6in6writing
D)6The6Authorized6Inspector6verbally6-6ans--A
When6must6an6evaluation,6to6determine6the6suitability6for6continued6use,6be6conducted?
A)6Evaluations6shall6be6conducted6when6a6tank6inspection6reveals6a6change6has6occurre
d6from6the6original6physical6condition6of6a6tank.
B)6Evaluations6shall6be6conducted6at6least6annually
C)6Evaluations6shall6be6conducted6at6an6interval6not6to6exceed6the6calculated6tank6inspe
ction6frequency
D)6Evaluations6shall6be6conducted6once6each6ten6years6of6service6-6ans--A
Inspection6Hold6points6and6minimum6documentation6to6be6submitted6upon6job6completio
n6for6repairs6and6alterations6will6be6designated6by6the:
A)6Owner/User's6engineering6department
B)6Repair6organization
C)6authorized6inspector
D)6Storage6tank6inspector6-6ans--C
In6a6SMAW6electrode,6the6"1"6refers6to:
A)6Electrode6type
B)6Coating6characteristics
C)6Chemical6composition
D)6Welding6position6-6ans--D
NDE6is6defined6as6those6inspection6methods6which6allow6materials6to6be6examined:
A)6without6damaging6the6component
B)6As6an6adjunct6to6visual6examination
C)6without6changing6or6destroying6their6usefulness
D)6Without6using6any6mechanical6force6-6ans--C
If6the6date6of6the6installation6of6a6component6is6unknown,6which6standard6shall6be6consid
ered6as6the6"as-built"6standard?
A)19586edition6of6API612C