Industrial process and refrigeration units with a 50 pound charge or more
with an annualized leak rate of _____ or more must have leaks repaired.
Right Ans - 35%

Unless plans are made to replace a system exceeding the maximum leak,
repairs must be made in; Right Ans - 30 days

Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as; Right
Ans - type A-1

All Refrigeration & HVAC systems are protected by a; Right Ans - Pressure
relief valve

A refrigerant sensor which will sound an alarm and automatically start a
ventilation system in occupied equipment rooms fall under; Right Ans -
ASHRAE Standard 15

Non-condensables will cause; Right Ans - High discharge pressure

A crankcase heater is often used to prevent refrigerant from migrating to the
oil during periods of: Right Ans - Low ambient tempurature

EPA regulations state that maintenance, service or repair involving the
removal of the following component is a "major repair" Right Ans -
compressor

What refrigerant can be used as a trace gas when checking for leaks? Right
Ans - R-22

What can be done with the refrigerant trace gas and nitrogen after the leak is
found? Right Ans - Release to the atmosphere

High pressure appliances can be evacuated to atmospheric pressure (O psig)
when; Right Ans - there is a leak

If a high pressure appliance containing 100 lbs. of an HCFC OTHER THAN R-22
refrigerant Recovery and/or Recycling equipment manufactured after

, November 15, 1993 must be evacuated to a level of; Right Ans - 10 inches
of vacuum

When dehydrating a system it should be evacuated to a level of; Right Ans -
500 microns

When recovering from a system with a refrigerant leak, recover to a level of;
Right Ans - 0 Psig

When using a recovery system manufactured after November 15, 1993 on a
system containing 100 lbs. of R-502 must be evacuated to; Right Ans - 10
inches of vacuum

If a high pressure appliance containing 210 lbs. of R-22 refrigerant Recovery
and/or Recycling equipment manufactured before November 15, 1993 must
be evacuated to a level of; Right Ans - 4 inches of vacuum

What conditions allow for a system to be opened and repaired without
recovering the refrigerant to the required vacuum level? Right Ans - a
system with a large leak and system pressure is atmospheric

A new split system should be checked for leaks by; Right Ans - pressurizing
the system with a few ounces of r-22 and an inert gas

An overcharged system will operate; Right Ans - less efficiently

Refrigerant should be removed from the condenser outlet if the condenser is;
Right Ans - Below the reciever

EPA regulations require that all Commercial and Industrial Process
Refrigeration containing more than 50lbs. of refrigerant MUST be repaired
when the annual leak rate exceeds; Right Ans - 35%

Proper recovery techniques begin with the use of appropriate recovery
equipment that has been certified by; Right Ans - EPA approved labratory

What happens to a refrigerant that is above the saturation temperature?
Right Ans - It remains a vapor state

Document information

Uploaded on
November 8, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LeCrae
4.0
(445)
Sold
2121
Followers
1409
Items
22329
Last sold
2 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions