ELECTRICAL-LEVEL 3, CHAPTER 1 EXAM FULLY SOLVED #3

What is the total load, in VA, for two small appliance branch circuits in a single-family
dwelling? - correct answer 3,000VA

What is the maximum number of general-purpose noncontinuous duty duplex
receptacles that can be connected to a 20A, 120V circuit in a commercial building?
What is the NEC® required load rating for each receptacle? - correct answer 13
receptacles; 180VA

What is the demand load, in amps, for a single circuit supplying one wall-mounted oven
rated 11.75kw, 1Ø, 240V, and a countertop cooking unit rated 9.6kw, 1Ø, 240V? -
correct answer 48.33A

What is the demand load, in amps, for one household electric range with a nameplate
rating of 16.75kw, 1Ø, 240V? - correct answer 41.67A

What is the minimum conductor ampacity for four 1,000W, 208V, 1Ø electric baseboard
heaters? - correct answer 24.04A

Load calculations for circuits supplying lighting units with ballasts are based upon
_____. - correct answer the ampere ratings of the ballasts

What is the calculated load, in amps, for a 120V circuit supplying four 150W recessed
incandescent fixtures and six recessed fluorescent fixtures operating continuously?
(Each fluorescent ballast is rated at 0.65A.) - correct answer 11.125A

The load for 6 of multi-outlet assembly used simultaneously is _____. - correct answer
1,080VA

The voltage drop for a 480V, 3Ø circuit with a load of 26.5A, using No. 8 stranded
copper conductors at a circuit length of 145 - correct answer 5.18V

The voltage drop for a 208V, 1Ø circuit with a load of 26.5A, using No. 8 stranded
copper conductors at a circuit length of 145 is _____. - correct answer 5.98V

What is the current-carrying ampacity for each of 10 No. 10 THHN copper conductors
installed in a single conduit? - correct answer 20A

What is the capacity, in amperes, for a 20A circuit breaker supplying a continuous load?
- correct answer 16A

The general lighting load (expressed as a unit load per square foot) for a warehouse is
_____. - correct answer 1/4VA/sq ft

The general lighting load for a store is _____. - correct answer 3VA/sq ft

Document information

Uploaded on
November 8, 2024
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.19

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
101
Followers
44
Items
5717
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions