How many wires do you need to transmit 3 phase power - Answers- 3 wires

The code defines a "continuous" load as one in which the load is likely to continue for _
hour or more. - Answers- 3

A transformer can be fed off the secondary feed. (T/F) - Answers- True

According to code, a wire located in a partially protected area such as under a roofed
open porch would be located in? - Answers- A damp location
Article 100 informational note

In dealing with motors and related equipment when the code specifies "in sight from" it
means that....... - Answers- The equipment must be visible.
Must not be more than 50ft.
Article 100

What is not permitted for connecting #6 wire and larger to terminal parts? - Answers-
Wire binding screws
110.14(A)

What is the head space required for a panel? - Answers- 6.5 ft
110.26(A)(3)

In all cases, the work space shall permit at least a _ degree opening of equipment
doors. - Answers- 90°
110.26(A)(2)

The terminal for the _ shall be the one connected to the screw shell. - Answers-
Grounded conductor
200.10(C)

Circuits fed from direct current systems ungrounded conductors 4awg or larger shall _
at all terminations. - Answers- Identify by polarity
210.5(C)(2)

In a dwelling unit kitchen which receptacles need to be GFCI
A) A receptacle installed to serve kitchen countertop surface
B) Receptacle installed under sink
C) A receptacle installed within 6ft from the the top inside edge of the bowl of the sink.
D) A and C
E) All of the above - Answers- D
210.8(A)(6&7)

, A recptacle is 6.5ft away from the outside edge of the bathtub or shower stall needs to
be GFCI protected. (T/F) - Answers- False
Anything installed within 6' needs GFCI, unless specified it is in a bathroom
210.8(A)(9)

Laundry branch circuits shall be on a _ branch circuit. - Answers- 20A
210.11(C)(2)

In general, branch circuit conductors supplying a single motor should have a capacity
not less than _% of the motor full loaded circuit rating. - Answers- 125%
210.19(A)
430.22

How many 2a fluorescent lights running for 10 hours straight can you put on a 20a
branch circuit? - Answers- 8
20x.8=16
16/2=8
210.19(A)(1)(a)

The branch circuit is rated at 15a, what is the total rating of the equipment fasted in
place where lighting units are also supplied?
A) 15a
B) 7.5a
C) 9.5 - Answers- B) 7.5A
210.23(A)(2)

The code requires at least one 20A circuit in the laundry, located within _ft from the
intended location of the washer. - Answers- 6 ft.
210.50(C)

The minimum wall space in a dwelling unit for a required outlet is? - Answers- 2ft
210.52(A)(2)(1)

What is the minimum width of a countertop that requires a receptacle? - Answers- 12"
210.52(C)(1)

A dwelling unit attached garage with four car spaces will need _ number of receptacle
outlets. - Answers- 4
210.52(G)(1)

A home having 1200sq ft of useable floor area shall have a minimum general lighting
load of how many watts? - Answers- 3600
3w per sq ft
3x1200
Table 220.12

Document information

Uploaded on
November 7, 2024
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA
3.8
(362)
Sold
2140
Followers
1448
Items
58873
Last sold
13 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions