NICET Inspect & Test LVL 2 Exam Questions And Well Elaborated Solutions Consider a smoke control system with a stairwell pressurization system. A _____ shall be provided in the air supply to the pressurized stairwell. A. Supervisory switch to monitor fan operation B. Manual fire alarm box C. Heat detector D. Smoke detector - answer -D. Smoke Detector NFPA 92 - 6.4.6.2.1 NFPA 72 states that smoke detector spacing shall be reduced where the airflow in a defined space exceeds _____ air changes per hour? A. 6 B. 7 C. 6.5 D. 7.5 - answer -D. 7.5 NFPA 72 17.7.6.3.3.1 Which of the following requires a visual inspection frequency of quarterly? (Select Two) A. Waterflow devices B. Radiant energy detectors C. Smoke detectors D. Visible notification appliances - answer -A. Waterflow devices B. Radiant energy detectors NFPA 72 Table 14.3.1 A project in an unsprinklered facility is using CI (circuit integrity) cable to provide a 2-hour fire rated resistance for a circuit. What is the pathway survivability rating? A. Level 1 B. Level 2 C. Level 3 D. Level 4 - answer -B. Level 2 NFPA 72 12.4.3 Consider communications methods for supervising station fire alarm systems. A communication technology which requires annunciation at the supervising station for degradation of the communications channel not to exceed 90 seconds from the time of actual failure is _____? A. Two way radio multiplex systems B. Performance based technology C. DACT systems D. One way private radio systems - answer -A. Two way radio multiplex systems NFPA 72 Table A.26.6.1 Consider an area where the temperature is 120 degrees Fahrenheit. The most appropriate type of smoke detector for this environment is _____? A. Smoke detectors are not appropriate B. Projected beam C. Photoelectric D. Ionization - answer -A. Smoke detectors are not appropriate NFPA 72 A.17.7.1.8 When testing an FSCS, which of the following modes are required to be tested? (Select Two) A. Manual override of normal mode B. Manual override of automatic mode C. Automatic override of normal mode D. Automatic override of alarm mode - answer -A. Manual override of normal mode B. Manual override of automatic mode NFPA 92 - 8.4.7.2 According to NFPA 72, cellular transmission is a performance based technology and as such _____? A. Requires AHJ approval B. Requires the use of a DACT C. Requires a secondary means of transmission D. Does not require a secondary communications path - answer -D. Does not require a secondary communications path NFPA 72 26.6.3.3 Consider the installation of a protected premises fire alarm system. All software and firmware shall be protected against unauthorized access. Access by persons who have are trained and authorized to either repair the control unit or to alter its site specific data or operating system program, thereby changing its basic mode of operation should be considered Access Level _____? A. 4 B. 1 C. 2 D. 3 - answer -A. 4 NFPA 72 A.23.2.2.2 Consider the use of spot type smoke detectors at elevations above 3,000 feet above sea level. This altitude may affect _____ detectors? A. Projected beam B. Photoelectric C. Air sampling D. Ionization - answer -D. Ionization

Content preview

NICET Inspect & Test LVL 2 Exam Questions
And Well Elaborated Solutions

Consider a smoke control system with a stairwell pressurization system. A _____
shall be provided in the air supply to the pressurized stairwell.

A. Supervisory switch to monitor fan operation
B. Manual fire alarm box
C. Heat detector
D. Smoke detector - answer -D. Smoke Detector
NFPA 92 - 6.4.6.2.1

NFPA 72 states that smoke detector spacing shall be reduced where the airflow in
a defined space exceeds _____ air changes per hour?

A. 6
B. 7
C. 6.5
D. 7.5 - answer -D. 7.5
NFPA 72 17.7.6.3.3.1

Which of the following requires a visual inspection frequency of quarterly?
(Select Two)

A. Waterflow devices
B. Radiant energy detectors
C. Smoke detectors
D. Visible notification appliances - answer -A. Waterflow devices
B. Radiant energy detectors
NFPA 72 Table 14.3.1

, A project in an unsprinklered facility is using CI (circuit integrity) cable to
provide a 2-hour fire rated resistance for a circuit. What is the pathway
survivability rating?

A. Level 1
B. Level 2
C. Level 3
D. Level 4 - answer -B. Level 2
NFPA 72 12.4.3

Consider communications methods for supervising station fire alarm systems. A
communication technology which requires annunciation at the supervising station
for degradation of the communications channel not to exceed 90 seconds from the
time of actual failure is _____?

A. Two way radio multiplex systems
B. Performance based technology
C. DACT systems
D. One way private radio systems - answer -A. Two way radio multiplex systems
NFPA 72 Table A.26.6.1

Consider an area where the temperature is 120 degrees Fahrenheit. The most
appropriate type of smoke detector for this environment is _____?

A. Smoke detectors are not appropriate
B. Projected beam
C. Photoelectric
D. Ionization - answer -A. Smoke detectors are not appropriate
NFPA 72 A.17.7.1.8

When testing an FSCS, which of the following modes are required to be tested?
(Select Two)

A. Manual override of normal mode
B. Manual override of automatic mode

Document information

Uploaded on
October 30, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.29

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro
3.6
(18)
Sold
159
Followers
5
Items
3828
Last sold
5 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions