NAB NHA Exam Study Guide Solutions the physical plant - Ans:-all designed, constructed, equipped, and maintained to protect health and safety of residents, personnel, public Life Safety Code (LSC) - Ans:-Entire construction plan and materials meet LSC standards|||CMS requires unless have waiver or exception. CMS grants waivers on SNFs; states on NFs (NFPA) - Ans:-National Fire Protection Association ||established LSC Purpose of LSC - Ans:-to provide reasonable degree of safety from fire. Waivers for Life Safety Code - Ans:-If CMS finds a state fire and safety code adequately protects residents and personnel thenLSC does not apply. OLder facilities may obtain a waiver if they are and have been in compliance with an older addition of LSC as specified by CMS.||Before a nursing home may be built it must present architectural plant to State Medicaid or designated agency that approves construction. All major renovations, such as additional beds, change in utilization of space, and so on must receive approval. The state provides guidelines on what must be a approved. Upkeep and repairs do not require prior approaval. Blue Prints - Ans:-keep as-built plans available for surveyors who do LSC inspection as well as for repair persons who may need prints for big jobs. ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER 2024 Page 2/101 LSC and other standards - Ans:-Building and contact standards are set by LSC, CMS, ANSI/ADAAG - (dependent on which the state chooses) and state and local codes. ||- for handicapped|-follow which on specific state requires (ANSI/ADAAG) LSC and ANSI/ADAAG - Ans:-LSC accepts both standards so they are essentially all LSC standards. Administrator does not need to know EVERY standard, but must keep a copy of the "LSC Handbook" as reference. The architect who designs the facility must know and incorporate all LSC and other standards, but it is advisable for the NHA to check his building to ensure compliance. LSC, ANSI/ADAAG, and CMS - Ans:-**- building materials - fire-rate according to number of stories. 2 hour and 1 hour rating|**- sprinklers - new buildings have automatically activated by smoke/heat|- exits - no room more than 100 feet from exit. Lighted exit signs of specific size. |- walls extend continuously to roof deck of next floor. wall finish must meet flame-spread requirements ( have certificate of this)|- furnishings - curtains and carpet must meet fire rating|- rooms - CMS requirements - 4 residents to room MAX. 80 sq ft/resident (multi-resident room), 100 sq ft for single occupancy. requirement for rooms| - Ans:-- direct access to corridor|- outside window (CMS) or door (LSC)|- privacy|- furnishing| separate bed, proper size and height| bedding appropriate to climate| individual closet space| bedside table| comfortable chair| enough overbid tables to meet needs of rsidents|- toilets (CMS, ANSI, ADA)|- bathing facilities (CMS)|- resident call system (CMS, LSC) 24/7 - back up system available|- temperature range (71-81 degree F) (three feet above floor), states set actual, A/C not required ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER 2024 Page 3/101 Doors - Ans:-All 44" or more in new construction (41.5 opening)|outside doors open egress.|no locks on resident door except staff has key (LSC)||Bathroom door 32" (ANSI/ADAAG)||Fire Doors with automatic hold-open devices required in corridors||(over bed tables not required for patient) corridors - Ans:-no dead-ends (LSC)||8 feet wide (CMS) Floors - Ans:-at or above ground level. (LSC) |Fire rating if carpeted. (LSC)|Non-slip bath/toilet (ANSI, LSC)|Asphalt tile best Fire alarms - Ans:-flashing and audible. |connect with local fire dept, if possible|must have NFPA 71 certification of fire alarm service| smoke detectors - Ans:-approved detectors requried smoking - Ans:-written regulations, enforced. |smoking ares w

Show more Read less
Institution
Nab
Course
Nab

Content preview

©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED

FIRST PUBLISH OCTOBER 2024




NAB NHA Exam Study Guide Solutions



the physical plant - Ans:✔✔-all designed, constructed, equipped, and maintained to protect health and

safety of residents, personnel, public


Life Safety Code (LSC) - Ans:✔✔-Entire construction plan and materials meet LSC standards|||CMS

requires unless have waiver or exception. CMS grants waivers on SNFs; states on NFs


(NFPA) - Ans:✔✔-National Fire Protection Association ||established LSC


Purpose of LSC - Ans:✔✔-to provide reasonable degree of safety from fire.


Waivers for Life Safety Code - Ans:✔✔-If CMS finds a state fire and safety code adequately protects

residents and personnel thenLSC does not apply. OLder facilities may obtain a waiver if they are and

have been in compliance with an older addition of LSC as specified by CMS.||Before a nursing home may

be built it must present architectural plant to State Medicaid or designated agency that approves

construction. All major renovations, such as additional beds, change in utilization of space, and so on

must receive approval. The state provides guidelines on what must be a approved. Upkeep and repairs

do not require prior approaval.


Blue Prints - Ans:✔✔-keep as-built plans available for surveyors who do LSC inspection as well as for

repair persons who may need prints for big jobs.


Page 1/101

, ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED

FIRST PUBLISH OCTOBER 2024




LSC and other standards - Ans:✔✔-Building and contact standards are set by LSC, CMS, ANSI/ADAAG -

(dependent on which the state chooses) and state and local codes. ||- for handicapped|-follow which on

specific state requires (ANSI/ADAAG)


LSC and ANSI/ADAAG - Ans:✔✔-LSC accepts both standards so they are essentially all LSC standards.

Administrator does not need to know EVERY standard, but must keep a copy of the "LSC Handbook" as

reference. The architect who designs the facility must know and incorporate all LSC and other standards,

but it is advisable for the NHA to check his building to ensure compliance.


LSC, ANSI/ADAAG, and CMS - Ans:✔✔-**- building materials - fire-rate according to number of stories. 2

hour and 1 hour rating|**- sprinklers - new buildings have automatically activated by smoke/heat|- exits

- no room more than 100 feet from exit. Lighted exit signs of specific size. |- walls extend continuously to

roof deck of next floor. wall finish must meet flame-spread requirements ( have certificate of this)|-

furnishings - curtains and carpet must meet fire rating|- rooms - CMS requirements - 4 residents to room

MAX. 80 sq ft/resident (multi-resident room), 100 sq ft for single occupancy.


requirement for rooms| - Ans:✔✔-- direct access to corridor|- outside window (CMS) or door (LSC)|-

privacy|- furnishing| separate bed, proper size and height| bedding appropriate to climate| individual

closet space| bedside table| comfortable chair| enough overbid tables to meet needs of rsidents|-

toilets (CMS, ANSI, ADA)|- bathing facilities (CMS)|- resident call system (CMS, LSC) 24/7 - back up

system available|- temperature range (71-81 degree F) (three feet above floor), states set actual, A/C not

required




Page 2/101

, ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED

FIRST PUBLISH OCTOBER 2024




Doors - Ans:✔✔-All 44" or more in new construction (41.5 opening)|outside doors open egress.|no locks

on resident door except staff has key (LSC)||Bathroom door 32" (ANSI/ADAAG)||Fire Doors with

automatic hold-open devices required in corridors||(over bed tables not required for patient)


corridors - Ans:✔✔-no dead-ends (LSC)||8 feet wide (CMS)


Floors - Ans:✔✔-at or above ground level. (LSC) |Fire rating if carpeted. (LSC)|Non-slip bath/toilet (ANSI,

LSC)|Asphalt tile best


Fire alarms - Ans:✔✔-flashing and audible. |connect with local fire dept, if possible|must have NFPA 71

certification of fire alarm service|


smoke detectors - Ans:✔✔-approved detectors requried


smoking - Ans:✔✔-written regulations, enforced. |smoking ares with non-combustible ashtrays, metal

containers with self-closing lids.|Prohibited areas include resident rooms and beds, oxygen, flammable

liquid storage.|proper signs posted.|supervise non-responsible.


ANSI/ADAAG(Americans with Disabilties Act Accessibility Guidelines) - Ans:✔✔-Make building available

to and usable by physically handicapped, no mental (blind, deaf, non-ambulatory, semi-ambulatory,

uncoordinated). ADAAG = MAKE BUILDINGS AVAILABLE TO ADA'S. |State decides whether to apply ANSI

or ADAAG standards to nursing homes


accessible route - Ans:✔✔-no incline more than 10%



Page 3/101

, ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED

FIRST PUBLISH OCTOBER 2024




Wheelchair passage - Ans:✔✔-32" bathroom doors||36" elsewhere


parking - Ans:✔✔-13 FEET||cannot block sidewalk; alley for 2 cars.|The number of handicap parking

places is determined from a grid issued by ANSI. It MUST BE NOTED THAT FOR EVERY EIGHT (8)

HANDICAP PARKING SLOTS, ONE MUST BE VAN ACCESSIBLE.||If the facility only has one handicapped

place, it must be van accessible.


ramps - Ans:✔✔-maximum rise 30". Slope not more than 1:10


What items must be accessible to wheelchair residents?| - Ans:✔✔-WATER FOUNTAINS, telephones

(non-Braille), light switches


Toilets and handrails - height - Ans:✔✔-toilets (Also ADA for staff) seat **17" to 19" height;||hand

rails/grab bars 33" to 36". |5% or more meet standards as determined by state and CMS||(easier to

replace with handicapped toilet)


Handrails - Ans:✔✔-outside ramp, stairwell, bathroom required by ANSI, and specific height.||CMS

requires in corridors.||ADAAG specifies all 34" to 38" in public places. |On stairwell must be 32" and

MUST EXTEND 12" beyond last step. (ANSI|


Monitored - Ans:✔✔-monitored nationally the Office of Civil Rights monitors ANSI. States may assign to

Fire Marshall, Medicaid Agency, other. |ADAAG is monitored by State Agency handling LSC and ANSI.




Page 4/101

Written for

Institution
Nab
Course
Nab

Document information

Uploaded on
October 22, 2024
Number of pages
101
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GraceAmelia West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
94
Member since
2 year
Number of followers
32
Documents
8974
Last sold
6 days ago
GraceAmelia\'s Emporium

Get a well Researched and Accurate Study Materials to Boost Your Grades and Excel Academically Offered by Seller Grace.

2.8

8 reviews

5
2
4
1
3
1
2
1
1
3

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions