Nicet Level 2 questions with Fully
Detailed Answers
4 - -Consider a room which is 40' square. How many 15cd wall mounted
strobes are required to adequately cover this space?

-Annually - -What is the testing frequency of a strobe?

-15 - -In a corridor application, visible appliances shall be rated not less
than ________ cd?

-4 hours - -Consider a household fire alarm system where the primary
power is provided by a circuit that can be switched off by means other than a
circuit breaker. The battery must be recharged in____________

-The control unit shall identify the affected detector when the compensation
limit has been reached. - -Where automatic drift compensation of detectors
is provided:

-3 - -A fire alarm system requires the use of smoke detectors in a corridor.
The corridor is 10' wide and 120' long. The ceiling of the corridor is smooth
and flat and 10' high. What is the minimum number of smoke detectors in
the corridor.

-One half smooth ceiling
NFPA 72 17.7.3.2.4.2(2)bi pg 98 - -The fire alarm system design for a room
called for smoke detector spacing based on a smooth flat ceiling. Upon
inspecting the room, it is determined that the ceiling has beams. The beam
spacing is less than 40% of the ceiling height. NFPA72 permits smooth
ceiling spacing in the direction parallel to the beams and __________ spacing
in the direction perpendicular to the beams.

-3 - -The working drawings for a fire alarm system show that 2 duct
detectors are required. The building is a single story with 4 HVAC units (1-
5,000 cfm, 1-4000 cfm, 1-3000 cfm, 1-2000 cfm) How many duct detectors
are required?

-15
NFPA72 18.4.3.1 pg107 - -The fire alarm system for a building requires the
use of audible notification appliances for public mode notification. To ensure
public mode signals are clearly heard, they shall have a sound level of at
least _______ db above the average ambient sound level?

-Location of utilities - -Site plans typically include:

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AccurateScores Not yet listed
View profile
Follow You need to be logged in order to follow users or courses
Sold
548
Member since
3 year
Number of followers
336
Documents
15259
Last sold
2 days ago

3.7

113 reviews

5
51
4
18
3
18
2
11
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions