Nicet level 1 Study Guide questions WITH Accurate Answers

Institution
Nicet Level 1
Course
Nicet level 1









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Nicet level 1
Course
Nicet level 1

Document information

Uploaded on
October 21, 2024
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Nicet level 1 Study Guide
questions WITH Accurate
Answers
When testing a water level supervisory switch serving a pressure tank a
signal shall indicate if the water level _____________from the required level

(NFPA 72, Table 14.4.3.2 17 (j) (4) - -rises or falls over 3 inches

-If combination audible/visible appliances are installed the location of the
installed appliance shall be determined by the requirements of _______.

(Nfpa 72 18.4.8.1) - -the visible appliance

-What is the maximum number of 12 gauge THHN wires that can be
installed in 1" EMT?

(Nec Annex C tables) - -26

-Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms.
What is their equivalent resistance? - -150 ohms

-A Room is 200' long and 150' wide and the 8' high ceiling is smooth and
flat. A spot type heat detector has been selected that is listed for a 50'
maximum spacing between detectors. According to NFPA 72 how many
detectors will be needed to protect this room?

x = - -12

-According to NFPA 72 the minimum number of restorable fixed temperature
spot type heat detectors that must be tested during each annual test is?

(NFPA 72 14.4.4.5.1) - -Two detectors or more on each initiating device
circuit

-According to NFPA 72 how many spot type heat detectors are required for a
space that is 80' long and 55 floor wide with a smooth 10' ceiling? the
detector is listed for a maximum space between detectors of 30' - -6

-What color code requirement for a spot type heat detector rated at 200 ゚ F -
-White (NFPA 72, Table 17.6.2.1)

, -Unless otherwise recommended by the manufacturers published
instructions single and multiple stations smoke alarms installed in one and 2
family dwellings shall be replaced every - -10 years from the day-of
manufacture. (NFPA 72, 14.4.7.1)

-Fire alarm cables are permitted to be strapped to conduit to support the
cable - -False (NEC 760.143)

-Where non power limited wiring is installed exposed it must be
mechanically protected within_____of the finished floor - -7' ft

-Fire-Warning equipment to be installed in residential occupancies shall
produce the audible emergency evacuation signal described in - -ANSI S3.41

-According to NFPA 72, visible notification appliance for non-sleeping areas
must be mounted between ___ and ___ inches above the finished floor - -80
& 96

-If system impairment occurs, the owner must be notified ___ within ___ - -in
writing & within 24 hours

-A 20 X 20' ft room with a 20'ft high ceiling requires at a minimum a ___
ceiling mounted strobe - -30 candela

-According to NFPA 72, a 40 x 40'ft room or area with a 10'ft ceiling is best
covered by a ___ cd visible notification appliance, centered on one wall. - -60

-Conductors returning to the fire alarm control panel (FACP) from the last
field device on the circuit might indicate a _____ circuit - -Class A

-Secondary power supplies for an emergency voice/alarm communication
fire alarm system shall be capable of operating for minimum of ___ of
standby followed by ___ of alarm. - -24 hrs & 15 mins

-The fire alarm system primary power branch circuit disconnecting means
must be ___ in color. - -Red

-The secondary power supply for protected premises shall automatically
provide power within ___ seconds when primary power fails. - -10 seconds

-Under which of the following conditions shall spot-type smoke detectors
NOT be installed? - -When the temperature is over 100*F

-Who is responsible for maintaining Personal Protective Equipment? - -YOU,
the employee

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AccurateScores Not yet listed
View profile
Follow You need to be logged in order to follow users or courses
Sold
548
Member since
3 year
Number of followers
336
Documents
15259
Last sold
2 days ago

3.7

113 reviews

5
51
4
18
3
18
2
11
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions