Oil burner test Questions & Answers

On a warm air furnace, the blower comes off and on in short cycles because Correct Ans-
The fan on/off differential is less than 40°F



What could cause a steam boiler to flood Correct Ans-Leaky tank less coil



Having to put water in a steam boiler once or twice a week is caused by Correct Ans-Weak
return line, radiator vents leaking, boiler sprung a leak



Some radiators on a steam system do not heat up because Correct Ans-The radiator vents
are clogged



On a hot water boiler the pressure is 30psi and the relief valve is open because Correct
Ans-Leaky tankless coil, bad pressure reducing valve, perforated tankless bladder



Some forced hot-water radiators are not heating because Correct Ans-Vent is clogged,
radiators are air bound, radiator valves clogged shut



A cad-cell primary control can lock-out safety because Correct Ans-Cad-cell is dirty, Cad-
cell is faulty, The cad-cell is not sensing flame



On a no heat call, a cad-cell primary control fired when TT is jumped out because Correct
Ans-The thermostat or thermostat wired are no good



In-step means Correct Ans-The primary control start circuit is closed


On a no heat call on a hot water system, the oil burner is off on high-limit, but the circulator is
not running because Correct Ans-The reverse is open, circulator motor burnt out,
switching relay is faulty

, Oil burner test Questions & Answers

The burner operates but there is no combustion because Correct Ans-There is too much air


On a replacement steam boiler installation, you should pipe full-size risers to the header. True
or false Correct Ans-False



What is the best way to remove surface oil? Correct Ans-Skimming



Where should the water like normally be in the sight glass when the boiler is off Correct
Ans-Center of the sight glass



What is the purpose of the automatic water feed on a steam boiler Correct Ans-To
maintain a safe minimum water line



What is the purpose of the hartford loop Correct Ans-To prevent siphoning of the boiler



What is the normal cut in pressure of a residential steam boiler Correct Ans-1/2 psi



What is the purpose of an oil safety valve Correct Ans-Prevents oil flow in the event of a
line rupture or excessive line inlet pressure



What does the term "approved" mean Correct Ans-Recognized by a nationally recognized
texting lab



What is a safety control Correct Ans-Any control used to prevent unsafe operation of the
uncontrolled equipment



What is a draft booster Correct Ans-Power operated fan installed in the chimney connector
to increase natural draft

, Oil burner test Questions & Answers

What is a "confined space?" Correct Ans-Any space who's volume is less than 50 cubic feet
per 1000 BTU's of all fuel burning equipment



What is "installation"? Correct Ans-Complete and ready for operation of any oil-burning
appliance



I hat is post purge control Correct Ans-A control that is designed to allow the power vent
or oil burner to operate after flame has been shut off



What is the "power venter" Correct Ans-An electrical device used to produce a negative
draft at the heating appliance



What is the largest exposed tank allowed in a building without a permit Correct Ans-660 g



What is tank approval Correct Ans-UL 80 UL 142


A supply tank shall be securely supported by ridged, non-combustible supports to prevent
settling, sliding or lifting. true or false Correct Ans-True



What is the largest amount of oil that can be stored with exposed tanks? Correct Ans-1320
g



What is the closest distance a supply tank can be to the burner Correct Ans-5 ft



What is the gauge of a 275 g above ground tank Correct Ans-12 gauge


The maximum amount of fuel may be delivered without a permit to store in effect provided
that application has been made in accordance with code. true or false Correct Ans-True

Document information

Uploaded on
October 21, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KeithAndrews
3.0
(28)
Sold
133
Followers
5
Items
14932
Last sold
4 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions