Florida Home Inspector Exam Questions
With Correct Answers 2024



Service .entrace .conductors .run .from .the .service .drop .to .the .service .box .or .service .panel.
.True .or .False? .- .correct .answer.True




The .service .size .is .determined .by .the .amperage .and .the .voltage .ratings .of .the .service. .-
.correct .answer.True




Is .the .service .drop .overhead .or .underground? .- .correct .answer.Overhead

Are .service .laterals .overhead .or .underground? .- .correct .answer.Underground

The .drip .loop .is .typically .part .of .the .service .drop. .True .or .False? .- .correct .answer.False

The .wire .size .for .the .service .drop .must .be .the .same .as .the .wire .size .for .the .service
.entrance .conductors. .True .or .False? .- .correct .answer.False




How .many .wires .would .you .typically .find .in .a .240-volt .service .drop? .- .correct .answer.3

What .would .4 .wires .mean? .- .correct .answer.3-phase .electricity

What .would .2 .wires .usually .mean? .- .correct .answer.120 .volt .service

List .7 .common .problems .with .service .drops. .- .correct .answer.1. .Overhead .wires .too .low.
2. .Damaged .or .frayed .wires.
3. .Trees .or .vines .interfering .with .wires.
4. .Wires .too .close .to .doors .or .windows.
5. .Wires .not .well-secured .to .the .house.
6. .Poor .connection .between .service .drop .and .service .entrance.
7. .Inadequate .clearance .from .roofs.

List .clearances .above .ground, .swimming .pools, .and .roofs. .- .correct .answer.above
.roadway--18 .ft.

above .driveway--12 .ft.
above .flat .roof--8 .to .10 .ft.
above .sloped .roof--18 .inches
away .from .water .in .swimming .pool--22.5 .ft

,3 .ft. .above .sloped .roof .with .pitch .> .4 .in .12
above .walkway--10 .ft.

The .service .entrance .conductors .run .from .the ._________ .to .the .___________. .- .correct
.answer.service .drop .to .service .box




All .service .entrance .conductors .must .be .in .conduit. .True .or .False? .- .correct .answer.False

All .service .entrance .conductors .must .be .attached .above .roof .level. .True .or .False? .-
.correct .answer.False




The .drip .loop .should .be .as .close .to .the .roof .as .possible. .True .or .False? .- .correct
.answer.False




List .10 .common .problems .with .service .entrance .conductors. .- .correct .answer.1. .No .drip
.loop

2. .No .mast .head
3. .Mast .head .not .weather .tight.
4. .Mast .or .conduit .bent.
5. .Mast .or .conduit .rusted.
6. .Mast .rotted .(if .wood).
7. .Mast .conduit .or .cable .not .well .secured.
8. .Mast .conduit .or .cable .not .weather .tight.
9. .Conduit .or .cable .not .well .sealed .at .house/wall .penetration.
10. .Cable .frayed, .damaged, .or .covered .by .siding.

List .4 .common .areas .of .water .penetration .into .service .entrances. .- .correct .answer.1.
.conduit .joints

2. .mast .head
3. .roof .flashing
4. .meter .base
5. .house .entry

List .2 .functions .of .the .drip .loop. .- .correct .answer.1. .Prevents .water .entry .into .the .conduit
.or .service .entrance .conductors.

2. .Shows .that .the .service .drop .wires .are .not .straining .the .splices.

Roughly .999 .out .of .1000 .houses .have ._________ .volts .available. .- .correct .answer.240

Roughly .999 .out .of .1000 .houses .have .__________ .service .entrance .wires. .- .correct
.answer.3




Load .calculations .are .part .of .a .home .inspection. .- .correct .answer.False

Implications .of .an .undersized .service .include:
a. .shock .hazard

,b. .fire .hazard
c. .shock .and .fire .hazard
d. .melting .insulation
e. .nuisance .tripping .of .the .main .fuses .and .breakers .- .correct .answer.e.

What .is .the .largest .single-phase .service .that .you .are .likely .to .find .in .a .home? .- .correct
.answer.400 .amps




What .size .copper .wire .would .you .expect .to .find .on .the .service .entrance .for:
a. .60-amp .service
b. .100-amp .service
c. .200-amp .service .- .correct .answer.a. .6 .gauge
b. .4 .gauge
c. .2-0 .gauge

Which .of .the .following .is .a .reliable .way .to .identify .the .service .size?
a. .the .size .of .the .service .drop .wires
b. .the .distribution .panel .rating
c. .the .service .box .rating
d. .the .service .entrance .conductor
e. .the .service .entrance .conduit .size .- .correct .answer.d.

Aluminum .is .an .acceptable .service .entrance .conductor .material. .True .or .False? .- .correct
.answer.True




A .fused .200-amp .service .has .two .100-amp .fuses .in .the .service .box. .True .or .False? .-
.correct .answer.False




If .you .can't .read .the .size .of .the .fuses .in .the .service .box, .you .should .remove .them .to .try .to
.get .a .better .look. .True .or .False? .- .correct .answer.False




Which .of .the .following .is .a .safety .issue:
a. .The .main .fuses .have .a .lower .rating .than .the .service .entrance .wire.
b. .The .main .fuses .have .a .higher .rating .than .the .service .entrance .wire.
c. .The .service .box .has .a .higher .rating .than .the .service .entrance .wires.
d. .The .service .box .has .the .same .rating .as .the .service .entrance .wires.
e. .The .distribution .panel .has .a .larger .rating .than .the .service .entrance .wires. .- .correct
.answer.b




The .service .box .can .be .inside, .outside, .or .in .the .garage. .True .or .False? .- .correct
.answer.True




There .can .be .up .to .10 .throws .to .disconnect .all .the .electricity .in .the .house. .True .or .False?
.- .correct .answer.False

, The .service .box .may .stand .alone .or .may .be .combined .with .the .distribution .panel. .True .or
.False? .- .correct .answer.True




List .common .conditions .you .might .find .in .a .service .box. .- .correct .answer.1. .poor .access
.or .location

2. .loose
3. .rust .or .water .in .box
4. .unprotected .opening
5. .damaged .parts
6. .overheating
7. .incorrect .fuse .or .breaker .size; .box .rating .too .small
8. .service .entrance .wires .exposed .in .house
9. .poor .connections
10. .illegal .taps
11. .neutral .wire .by-passes .service .box
12. .fused .neutral .wire
13. .fuses .upstream .of .disconnect .switch
14. .obsolete .box
15. .exterior .box .not .weather-tight
16. .box .not .rated .for .aluminum

The .functions .of .earth .grounding .systems .include: .- .correct .answer.1. .Dissipate .electricity
.from .lightning.

2. .Avoid .static .electricity .buildup.

The .grounding .electrode .conductor .may .also .be .called .__________. .- .correct .answer.the
.ground .wire




You .are .allowed .to .ground .to .the .gas .piping. .True .or .False? .- .correct .answer.False

The .grounding .systems .are .connected .to .the .house .neutral .at .the .___________. .- .correct
.answer.Service .box




From .the .point .where .the .ground .and .neutral .wires .connect, .there .are .2 .paths .to .ground.
.What .are .they? .- .correct .answer.Through .the .neutral .service .wire .or .through .the

.grounding .electrode .conductor .to .water .pipes .or .ground .rods.




List .5 .destinations .where .ground .wires .can .terminate. .- .correct .answer.1. .metal .water
.pipes

2. .metal .rods .driven .into .the .ground
3. .wires .buried .in .the .footings .(UFER .ground)
4. .buried .grounding .plates .or .rings
5. .frame .of .metal .buildings
6. .metal .well .casings

List .common .problems .found .with .grounding .systems. .- .correct .answer.1. .no .ground

Document information

Uploaded on
October 15, 2024
Number of pages
86
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
RANKGRADES
3.8
(22)
Sold
93
Followers
16
Items
4794
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions