Preview 3 out of 25 pages

Study Guide California Designated Operator ( 16) Study Guide The following are not "underground storage tanks" - Answer-1. A farm Tank 2. A heating oil tank 3. A hydraulic lift tank 4. A liquefied petroleum gas tank 5. A septic tank 6. A sump, pit, pond or lagoon 7. A wastewater treatment tanks except if it is part of a UST system 8. A pipeline located in a refinery except if it is connected to an underground storage tank 9. A storm water or waste water collection system 10. Tanks containing radioactive materials that are covered by the Atomic Energy Act 11. An emergency containment tank that is normally empty 12. Drums located in a basement and which contain 55 gallons or less of a hazardous material 13. Underground storage tanks containing hazardous waste that are regulated by the DTSC EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024. Page 2/25 14. A tank and associated piping located in a vault or basement and which meets the requirements of section 25283.5 of the Health and Safety code Title An "existing underground storage tank" means - Answer-any underground storage tank installed prior to January 1, 1984. Tank "ullage" is - Answer-space between the product level and the top of the tank (i.e., it is the empty space within the tank) All new underground storage tanks including associated piping shall have - Answer-primary and secondary containment The design and construction of the primary containment on all new tanks, including any integral secondary containment system, shall be approved by - Answer-an independent testing organization in accordance with industry codes, voluntary consensus standards, or engineering standards The primary containment stem on all new tanks with or without an integral secondary containment system shall - Answer-wear plates (striker plates) installed below all accessible openings. A secondary containment system for a new tank which is not an integral part of the of the primary containment shall be - Answer-designed and constructed according to an EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024. Page 3/25 engineering specification approved by a state registered professional engineer or according to a nationally recognized industry code or engineering standard. The following requirements apply to non-integral secondary containment on new tanks - Answer-1. Must contain 100% of the usable capacity of the primary containment for a single container 2. Must contain 150% of the largest container or 10% of the aggregate volume for multiple containers 3. If open to rainfall, must accommodate the amount of rain that could enter the system during a 24hour, 25-year storm in addition to the applicable volume in items 1 or 2 above. 4. If backfill material is placed in the secondary containment system, the system must meet specific standards [see 2631 (d) (3)] 5. Must be equipped with a collection system to accumulate, store and permit removal of any liquid within the system. 6. The floor of the system must be sloped to a collection sump and meet other design standards [see 2631 (d) (5)]. 7. If a membrane liner is used (e.g., excavation liner), the design shall meet specific design standards [seee 2631 (d) (6)] New underground storage tanks with secondary containment shall be - Answer-designed and installed so that any loss of hazardous substance from the primary containment will be detected by an interstitial monitoring device or method. EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024. Page 4/25 Owners or operators of new underground storage tanks shall implement a monitoring program that: - Answer-1. Is approved by the local agency and specified in the operating permit. 2. Includes either visual or mechanical monitoring of the interstitial space. A visual interstitial monitoring plan for new tanks shall include: - Answer-1. Inspection of all tank surfaces and the floor beneath the tank by direct viewing 2. Daily inspections except on weekends or recognized state and federal holiday. (This requirement can be reduced at the discretion of the local agency depending but shall not be less than weekly). 3. Recording of the liquid level in the tank at the time of each inspection. 4. Provisions for sample collection and analysis of any observed liquid release. If analysis determines that a release may have occurred, a tank integrity test must be conducted. A monitoring program that relies on the mechanical or electrical detection in the interstitial space shall include: - Answer-1. Continuous monitoring of the interstitial space 2. An audible and visual alarm system approved by the local agency 3. For methods where that use indirect monitoring to determine if a release has occurred (e.g., wet annular or continuous vacuum), the monitoring program shall specify the proposed methods for determining if a release has occurred All monitoring programs for new tank systems (whether visual or mechanical), shall contain the following: - Answer-1. A written procedure which establishes EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024. Page 5/25 a. The frequency of performing the monitoring b. The methods and equipment, identified by name and model, to be used for performing the monitoring c. The location where the monitoring will be performed d. The name(s) and title(s) of the individual(s) responsible for performing the monitoring and/or maintaining the equipment e. The reporting format f. The preventative maintenance schedule g. A description of the training necessary for the operation of the tank systems and monitoring equipment 2. A response plan that demonstrates that the release will be removed from the secondary containment system in a timely manner (but no more than 30 days) and includes: a. A description of the proposed equipment to be used to remove the hazardous substance b. The name(s) and title(s) of the person(s) responsible for authorizing the work. Underground storage tanks that contain motor vehicle fuel can be constructed to an alternate standard. UST systems constructed to the alternate standard must meet specific design requirements including: - Answer-1. Tanks shall be constructed of fiberglass reinforced plastic, cathodically protected steel, or steel clad with fiberglass reinforced plastic. EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024. Page 6/25 2. If double walled tanks are not installed, specific requirements for installation of a leak interception system must be met (e.g., excavation liner with low point sump) New underground storage tanks which are constructed per the alternate construction requirements (i.e., contain motor vehicle fuel) shall be monitored as follows : - Answer-1. Have an appropriately designed leak interception device [Title 23 section 2634 (d)] 2. The motor vehicle fuel inventory shall be reconciled [Title 23 section 2646] 3. The underground piping shall be tested and monitored [Title 23 section 2636] Primary and secondary containment systems for ALL new underground storage tanks shall be designed, constructed, tested and certified to comply, as applicable, to the following: - Answer-1. All tanks shall be tested at the factory before being transported 2. The outer surface of the steel tanks shall be cathodically protect

Content preview

EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024.




Study Guide California Designated
Operator ( 16) Study Guide

The following are not "underground storage tanks" - Answer✔✔-1. A farm Tank


2. A heating oil tank


3. A hydraulic lift tank


4. A liquefied petroleum gas tank


5. A septic tank


6. A sump, pit, pond or lagoon


7. A wastewater treatment tanks except if it is part of a UST system


8. A pipeline located in a refinery except if it is connected to an underground storage tank


9. A storm water or waste water collection system


10. Tanks containing radioactive materials that are covered by the Atomic Energy Act


11. An emergency containment tank that is normally empty


12. Drums located in a basement and which contain 55 gallons or less of a hazardous material


13. Underground storage tanks containing hazardous waste that are regulated by the DTSC




Page 1/25

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024.



14. A tank and associated piping located in a vault or basement and which meets the

requirements of section 25283.5 of the Health and Safety code


Title


An "existing underground storage tank" means - Answer✔✔-any underground storage tank

installed prior to January 1, 1984.


Tank "ullage" is - Answer✔✔-space between the product level and the top of the tank (i.e., it is

the empty space within the tank)


All new underground storage tanks including associated piping shall have - Answer✔✔-primary

and secondary containment


The design and construction of the primary containment on all new tanks, including any integral

secondary containment system, shall be approved by - Answer✔✔-an independent testing

organization in accordance with industry codes, voluntary consensus standards, or engineering

standards


The primary containment stem on all new tanks with or without an integral secondary

containment system shall - Answer✔✔-wear plates (striker plates) installed below all accessible

openings.


A secondary containment system for a new tank which is not an integral part of the of the

primary containment shall be - Answer✔✔-designed and constructed according to an




Page 2/25

, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED. FIRST PUBLISH OCTOBER 2024.



engineering specification approved by a state registered professional engineer or according to a

nationally recognized industry code or engineering standard.


The following requirements apply to non-integral secondary containment on new tanks -

Answer✔✔-1. Must contain 100% of the usable capacity of the primary containment for a single

container


2. Must contain 150% of the largest container or 10% of the aggregate volume for multiple

containers


3. If open to rainfall, must accommodate the amount of rain that could enter the system during

a 24hour, 25-year storm in addition to the applicable volume in items 1 or 2 above.


4. If backfill material is placed in the secondary containment system, the system must meet

specific standards [see 2631 (d) (3)]


5. Must be equipped with a collection system to accumulate, store and permit removal of any

liquid within the system.


6. The floor of the system must be sloped to a collection sump and meet other design standards

[see 2631 (d) (5)].


7. If a membrane liner is used (e.g., excavation liner), the design shall meet specific design

standards [seee 2631 (d) (6)]


New underground storage tanks with secondary containment shall be - Answer✔✔-designed

and installed so that any loss of hazardous substance from the primary containment will be

detected by an interstitial monitoring device or method.

Page 3/25

Document information

Uploaded on
October 15, 2024
Number of pages
25
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Emillect
3.0
(4)
Sold
34
Followers
2
Items
2999
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions