• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 9 pages
Exam (elaborations)

fdny z51 rmo NEWEST 2024 WITH COMPLETE QUESTIONS AND CORRECT VERIFIED ANSWERS (DETAILED ANSWERS) ALREADY GRADED A+ 100% GUARANTEED TO PASS CONCEPTS!!! A technician has been asked to estimate the cost of operating a 5 horsepower motor because the plant is

Document preview thumbnail
Preview 2 out of 9 pages

fdny z51 rmo NEWEST 2024 WITH COMPLETE QUESTIONS AND CORRECT VERIFIED ANSWERS (DETAILED ANSWERS) ALREADY GRADED A+ 100% GUARANTEED TO PASS CONCEPTS!!! A technician has been asked to estimate the cost of operating a 5 horsepower motor because the plant is billed by energy consumed as kilowatt hours the technician will calculate the conversion the equivalent in energy of a 5 horse power motor operating for 9 hours and kilowatt hours is closest to - ANSW..33.6 (one horsepower equals. 746

Content preview

fdny z51 rmo NEWEST 2024 WITH COMPLETE QUESTIONS AND CORRECT
VERIFIED ANSWERS (DETAILED ANSWERS) ALREADY GRADED A+ 100%
GUARANTEED TO PASS CONCEPTS!!!




A technician has been asked to estimate the cost of operating a 5 horsepower motor
because the plant is billed by energy consumed as kilowatt hours the technician will
calculate the conversion the equivalent in energy of a 5 horse power motor operating for
9 hours and kilowatt hours is closest to - ✔✔ANSW✔✔..33.6 (one horsepower equals.
746)

The only refrigerant/temperature chart available to refrigerate engineer list the
temperature in ゚C if the chart indicates a Celsius temperature of 5゚ the equivalent In
Fahrenheit is - ✔✔ANSW✔✔..41゚ (1.8 × 5)+ 32 equals)

How do you start a centrifugal chiller - ✔✔ANSW✔✔..Start the chilled water pump then
start the condenser water pump check oil start cooling tower start compressor

A circuit breaker has a similar function as what - ✔✔ANSW✔✔..A fuse

A standpipe system will be out of service for 2 days how long should there be fire watch
- ✔✔ANSW✔✔..The entire time the standpipe is out of service

In a building with a multi zone How does each zone get supplied with water -
✔✔ANSW✔✔..Each zone will have its own automatic water supply

Which service valve should be Install to isolate dual pressure relief valve while keeping
the system in service - ✔✔ANSW✔✔..3 way valve

How many BTU's are removed in a 30 ton system - ✔✔ANSW✔✔..360000 BTU's per
hour

An automatic expansion valve maintains a constant - ✔✔ANSW✔✔..Evaporator
pressure

If the air lovers below the fans in an induced draft cooling tower become clogged the
result would be - ✔✔ANSW✔✔..Higher return water temperature

, You have a cold front and there is a sudden drop in temperature the thermostat will
cause the solenoid valve - ✔✔ANSW✔✔..Close and pump the compress it down and
shut down on low pressure

What happens when a steam turbine reaches critical speed - ✔✔ANSW✔✔..Turbine will
vibrate violently

What Device automatically controls the speed of a steam turbine -
✔✔ANSW✔✔..Governor valve

Under what circumstances is it OK to chain and exit - ✔✔ANSW✔✔..It is never OK

The heat remove from the refrigerator in the condenser is - ✔✔ANSW✔✔..Sensible and
latent heat



the efficiency of the refrigerant cycle is affected by the operation of the condenser. Of
the following, a more efficient centrifugal compressor operation results from -
✔✔ANSW✔✔..lowering the condenser pressure

In most semi hermetic compressors, the suction vapor is used for - ✔✔ANSW✔✔..cools
the motor

The amount of refrigerant that flows through the orifices of an economizer is determined
by the - ✔✔ANSW✔✔..difference between the high side and the low side pressure

the instalation of an inline refrigerant cleaning system is advisable - ✔✔ANSW✔✔..to
remove impurities from the system

a refrigerant engineer verifies that a condenser pump is cavitation of the following the
most likely cause for this condition is: - ✔✔ANSW✔✔..a faulty cooling tower water level
controller

when an expansion valve is operating properly, at the end of the evaporator will contain
- ✔✔ANSW✔✔..only superheated vapor

a centrifugal water pump is considered to be fully primed when - ✔✔ANSW✔✔..the
pump is full of liquid

A refrigeration compressor has failed to turn on. the engineer on duty verifies the
electrical circuit to the motor, including all switches and circuit breakers is complete,
according to recomended service practice, the next item to be checked would likely be
the: - ✔✔ANSW✔✔..temperature and pressure controls

Document information

Uploaded on
October 14, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BestwriterGuru
4.8
(725)
Sold
257
Followers
34
Items
5538
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions