A faulty condenser fan motor on an air conditioning system will cause these symptoms..... - Answer High suction pressure and high discharge pressure When connecting copper to steel the recommended brazing filler alloy is a... - Answer 45 percent silver alloy A partially iced over evaporator can be caused by... - Answer An undercharge Heat added to the refrigerant in vapor state after the evaporation process is called.... - Answer Superheat Why must refrigerant in the suction line be slightly warmer than the saturation temperature? - Answer Prevent liquid slugging of the compressor Heat which causes a change of temperature of substance is called.... - Answer Sensible heat The thermostatic expansion valve has three operating pressures.... - Answer Evaporator pressure, spring pressure, and sensor bulb pressure What is the maximum operating pressure setting for an acetylene torch? - Answer 15 psig Heat added to a substance without a rise in temperature; (example: liquid refrigerant to gas) this process is called? - Answer Latent heat of vaporization An automatic expansion valve is best suited.... - Answer When the load remains fairly constant

Content preview

Air Conditioning Certification Exam
Questions With Verified Solutions.
A faulty condenser fan motor on an air conditioning system will cause these symptoms..... - Answer
High suction pressure and high discharge pressure



When connecting copper to steel the recommended brazing filler alloy is a... - Answer 45 percent silver
alloy



A partially iced over evaporator can be caused by... - Answer An undercharge



Heat added to the refrigerant in vapor state after the evaporation process is called.... - Answer
Superheat



Why must refrigerant in the suction line be slightly warmer than the saturation temperature? - Answer
Prevent liquid slugging of the compressor



Heat which causes a change of temperature of substance is called.... - Answer Sensible heat



The thermostatic expansion valve has three operating pressures.... - Answer Evaporator pressure,
spring pressure, and sensor bulb pressure



What is the maximum operating pressure setting for an acetylene torch? - Answer 15 psig



Heat added to a substance without a rise in temperature; (example: liquid refrigerant to gas) this process
is called? - Answer Latent heat of vaporization



An automatic expansion valve is best suited.... - Answer When the load remains fairly constant

, If the cut-off plate is removed from a blower assembly, how would this effect blower performance? -
Answer It would reduce air flow



When using an electronic leak detector, the sensor probe.... - Answer Should be moved approximately
1 inch every two seconds



A thermostatic expansion valve is designed to maintain... - Answer Constant evaporator superheat



A refrigerant gives up heat when... - Answer It condenses



10 lbs of refrigerant passing through a water cooled condenser will lose 20 Btu's of heat per lb. If 10 lb of
water passes through the condenser with an entering temperature of 80 degrees F. The temperature of
the water leaving the condenser is..... - Answer 100 degrees F



Which of the following symptoms would be indicative of an oil logged condenser? - Answer High
discharge line pressure and low liquid line pressure



A compressor that has a broken valve will cause these symptoms.... - Answer High suction pressure and
low discharge pressure



The state of the refrigerant in the suction line should be... - Answer Low pressure / low temperature
vapor



The heat removed from the refrigerant by the condenser is.... - Answer Both sensible and latent heat



The first function of a condenser must perform is to __________ the refrigerant before condensing can
occur. - Answer De-superheat



A dirty evaporator in an air conditioning system will cause these symptoms... - Answer Low suction
pressure and low discharge pressure

Document information

Uploaded on
October 8, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TestSolver9
3.6
(182)
Sold
1026
Followers
131
Items
32321
Last sold
7 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions