10/8/24, 5:50 AM
Scheduled maintenance: October 9, 2024 from 01:45 AM to 03:45 AM
API 570 Certification Data Sheets - MSTS-Training.com
JEEREMIAH
Terms in this set (57)
CUI affects Carbon Steel (Temperature 10-350F (574 7.4.4.1e)
Range)
B31.3 recommended minimum preheat <32*F (31.3 - 330.1.1)
temps become REQUIRED
Standard Temperature range for PT exam. 40 - 125*F (V - T-652)
Minimum flash point for hydrocarbons used 120*F (5.8.1)
for leak testing?
Temp when UT readings should be 120 - 400*F (574 - 7.4.4.1.h)
compensated for temperature?
Typical dew point for hydrochloric acid? 130*F (571 - 4.3.7.3.d)
Most aggressive CUI temperature range? 212-250*F (571 - 4.3.3.3.d)
Typical dew point for sulfuric acid? 280*F (571 - 4.3.7.3.c)
Minimum pre-heat temperature when 300*F (8.2.3.2)
performing pre-heat in lieu of PWHT?
Minimum pre-heat temperature when 300*F (8.2.3.3.c)
performing a local PWHT in lieu of a full
encirclement PWHT?
Starting temperature for Sulfidation on 450*F (574 - 7.4.6.2.j)
Carbon Steel (sulfur content >0.5% by 500*F (571 - 4.4.2.3.c)
weight)?
Operating temperatures which cause 650-1100*F (574 - 3.1.39)
temper-embrittlement of low chromes?
Operating temperature when Corrosion 750*F (5.1.1.1)
Specialist must input an inspection plan?
Graphitization begins for carbon steel 800*F (574 - 10.3.5.2.4)
materials (Temperature)
Creep begins in 1-1/4% chrome materials 900*F (574 - 7.4.11.1)
(Temperature)
Maximum temperature for UT transducers 1100*F (574 - 10.2.1.5.1)
with special delay lines
Carbon steel PWFT temperature 1100-1200*F (31.3 - Tbl 331.1.1)
Minimum temperature of pipe during MDMT +10*F (5.8.3)
pressure test, when wall thickness is < (or =)
2"
Minimum temperature of pipe during MDMT + 30*F (5.8.3)
pressure test, when wall thickness is >2"
1/3
Scheduled maintenance: October 9, 2024 from 01:45 AM to 03:45 AM
API 570 Certification Data Sheets - MSTS-Training.com
JEEREMIAH
Terms in this set (57)
CUI affects Carbon Steel (Temperature 10-350F (574 7.4.4.1e)
Range)
B31.3 recommended minimum preheat <32*F (31.3 - 330.1.1)
temps become REQUIRED
Standard Temperature range for PT exam. 40 - 125*F (V - T-652)
Minimum flash point for hydrocarbons used 120*F (5.8.1)
for leak testing?
Temp when UT readings should be 120 - 400*F (574 - 7.4.4.1.h)
compensated for temperature?
Typical dew point for hydrochloric acid? 130*F (571 - 4.3.7.3.d)
Most aggressive CUI temperature range? 212-250*F (571 - 4.3.3.3.d)
Typical dew point for sulfuric acid? 280*F (571 - 4.3.7.3.c)
Minimum pre-heat temperature when 300*F (8.2.3.2)
performing pre-heat in lieu of PWHT?
Minimum pre-heat temperature when 300*F (8.2.3.3.c)
performing a local PWHT in lieu of a full
encirclement PWHT?
Starting temperature for Sulfidation on 450*F (574 - 7.4.6.2.j)
Carbon Steel (sulfur content >0.5% by 500*F (571 - 4.4.2.3.c)
weight)?
Operating temperatures which cause 650-1100*F (574 - 3.1.39)
temper-embrittlement of low chromes?
Operating temperature when Corrosion 750*F (5.1.1.1)
Specialist must input an inspection plan?
Graphitization begins for carbon steel 800*F (574 - 10.3.5.2.4)
materials (Temperature)
Creep begins in 1-1/4% chrome materials 900*F (574 - 7.4.11.1)
(Temperature)
Maximum temperature for UT transducers 1100*F (574 - 10.2.1.5.1)
with special delay lines
Carbon steel PWFT temperature 1100-1200*F (31.3 - Tbl 331.1.1)
Minimum temperature of pipe during MDMT +10*F (5.8.3)
pressure test, when wall thickness is < (or =)
2"
Minimum temperature of pipe during MDMT + 30*F (5.8.3)
pressure test, when wall thickness is >2"
1/3