EPA 608 TYPE 1 TEST ACTUAL EXAM
Technicians who perform sealed system service on small appliances must have; -
ANSWER: Type I or Universal certification.

A small appliance is defined by EPA as; - ANSWER: Appliances manufactured,
charged, and hermetically sealed in a factory with 5 Lbs or less of refrigerant

Type I Certification is required for; - ANSWER: persons handling refrigerant during
maintenance, service, or repair of small appliances

If regulations change after the technician becomes certified; - ANSWER: The
technician is responsibility for complying with any future changes in the regulations.

Recovery equipment manufactured after November 15, 1993 must be; - ANSWER:
capable of recovering 90% of the refrigerant in the compressor os operating; 80% of
refrigerant if its not or 4 inches of vaccum

Which of the following is true of small appliances refrigerant leaks; - ANSWER: EPA
does not require repair, but leaks should be repaired whenever possible.

Recovery equipment manufactured after November 15, 1993 must be capable of
recovering; - ANSWER: 90% refrigerant or or achieving 4 inches of vacuum.

Recovering multiple types of refrigerants in the same cylinder; - ANSWER: will make
the reclaimed refrigerants non reclaimable and a charge for disposal may be levied.

Self-contained or active recovery equipment; - ANSWER: Has its own means of
recovery.

System-dependant or passive recovery equipment; - ANSWER: Captures refrigerant
into a non-pressurized container with assistance of the appliance compressor.

What is defined as a non-condensible? - ANSWER: Air

When using a system-dependent recovery system on an appliance that has an
operating compressor, the technician should; - ANSWER: Run the compressor and
recover from the high side of the system.

When using a system-dependent recovery system on an appliance that has a non-
operating compressor, the technician should; - ANSWER: Place access fitting on both
the low and high side of the system.

System-dependant devices may only be used on appliances containing; - ANSWER:
15 pounds of refrigerant or less.

, Small appliances are equipped with a straight piece of tubing (process stub) used to;
- ANSWER: install a piercing type access valve fitting.

If a strong odor is detected while performing the recovery process, - ANSWER: A
compressor burnout has likely occurred.

After the refrigerant has been recovered, which of the following can be used to flush
the system? - ANSWER: Nitrogen

When filling a charging cylinder with a regulated refrigerant; - ANSWER: The
refrigerant vapor that is vented off the top of the cylinder must be recovered.

If after installing a fitting for the purpose of recovering the appliances refrigerant,
you find that the system pressure is 0 psig; - ANSWER: Recovery is not required.

Applying heat with a heat gun to the compressor; - ANSWER: can help vaporize any
trapped liquid refrigerant during recovery.

Refrigerators in the 1950's and earlier may have used what refrigerants (recovery is
not required)? - ANSWER: Methyl Formate, Methyl Chloride, or Sulfur Dioxide.

Small appliances in recreational vehicles may use refrigerants such as Ammonia,
Hydrogen, or water, and therefore; - ANSWER: The refrigerant should not be
recovered.

Recovery equipment manufactured before November 15, 1993 must be capable of
recovering. - ANSWER: 80 percent of the refrigerant or achieving 4 inches of vacuum.

When pressurizing a system with nitrogen you should; - ANSWER: charge through a
pressure regulator;place a relief valve in the downstream line from the pressure
regulator.

After recovering refrigerant, the Nitrogen used to flush the system may be: -
ANSWER: legally vented.

The sale of CFCs and HCFC's are - ANSWER: restricted to certified technicians

ARI 740 sets - ANSWER: recovery requirements

All equipment must be equipped with - ANSWER: low loss fittings

Low loss fittings should be able to - ANSWER: close manually or automatically when
hoses are disconnected to minimize refidgerant loss

Before beginning a refrigerant recovery procedure, it is necessary - ANSWER: to
know the type of refrigerant that is in the system.

Connected book
 image
Publisher: 2024 ISBN: 9798324615529 Edition: Unknown

Document information

Uploaded on
September 25, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
tutorsection1
4.9
(455)
Sold
55
Followers
8
Items
1077
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions