• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 48 pages
Exam (elaborations)

Quality Control (BLUE) UPDATED Actual Exam Questions and CORRECT Answers

Document preview thumbnail
Preview 4 out of 48 pages

Quality Control (BLUE) UPDATED Actual Exam Questions and CORRECT Answers A buret with a glass stopcock can be used for: A. Alcohols C. Acids B. Bases D. Salts - CORRECT ANSWER- C The operation speed for paddle in a dissolution apparatus is: A.150 rpm C.100 rpm B. 200 rpm D. 50 rpm - CORRECT ANSWER- D

Content preview

Quality Control (BLUE) UPDATED Actual
Exam Questions and CORRECT Answers
A buret with a glass stopcock can be used for:
A. Alcohols C. Acids

B. Bases D. Salts - CORRECT ANSWER- ✔✔C


The operation speed for paddle in a dissolution apparatus is:
A.150 rpm C.100 rpm

B. 200 rpm D. 50 rpm - CORRECT ANSWER- ✔✔D


Radiant energy refers to:
A. Visible C. UV

B. IR D. All of the above - CORRECT ANSWER- ✔✔D


High pressure liquid chromatography method of analysis is more advantageous than the other
column chromatography as to:
A. Ease to operate C. More precise

B. Greater speed D. All of the above - CORRECT ANSWER- ✔✔D


Content uniformity test is to be performed for all tablet products whose active ingredient is:
A. 50 mg or smaller C. 130-324 mg

B. 324 mg or more D. 130 mg or less - CORRECT ANSWER- ✔✔A


The statement of expiration date assures the patient:
A. Absence of toxicity C. Complete absorption of drug

B. Full therapeutic efficacy D. Absence of interaction - CORRECT ANSWER- ✔✔B


A factor obtained by taking the ratio of the actual normality to the theoretical normality is:
A. Titer C. Flame photometer

,B. Normality factor D. Polarimeter - CORRECT ANSWER- ✔✔B


To measure the optical activity of a sample, the instrument used is:
A. Spectrometer C. Flame photometer

B. Refractometer D. Polarimeter - CORRECT ANSWER- ✔✔D


In phenol content determination of a volatile oil, the layer in the graduated neck of the cassia
flask read 2.7 ml obtained from a sample of 10 ml of the oil after treatment of KOH. The %
phenol is:
A. 69.8 C. 73.0

B. 27.0 D. 7.30 - CORRECT ANSWER- ✔✔C


Using the Karl Fischer method, determine the moisture content of a sample of raw material
where a 63 mg sample consumed 0.75 ml of titrant. Water equivalence factor is 1.10.
A. 1.8% C. 2.10%

B. 1.3% D. 0.74% - CORRECT ANSWER- ✔✔B


During shipment of the finished product to the wholesale or retail outlets, the responsible
person
should ensure:
A. Product identification C. Segregation of different types

B. No damage, spillage or breakage D. All of the above - CORRECT ANSWER- ✔✔D


To find the mEq factor of an oxidizing agent is to divide the molecular weight by:
A. Valence C. No. of electrons gained (VDGEROA)

B. No. of electron lost D. Replaceable hydrogen - CORRECT ANSWER- ✔✔C


Lower control limit if mean is 10.5 ml and one standard deviation is 0.025.
A. 10.450 ml C. 10.575 ml

B. 10.420 ml D. 10.425 ml - CORRECT ANSWER- ✔✔D

,Gas chromatography is utilized in the separation and identification of:
A. Amino acid C. Volatile liquids in a mixture

B. Alkaloids D. Blood components - CORRECT ANSWER- ✔✔C


The name of the originator of using silver nitrate as the titrant and potassium chromate as the
indicator in volumetric precipitation of chloride.
A. Volhard C. Mohr

B. Beer D. Fajan - CORRECT ANSWER- ✔✔C


Reassay date of thiamine Hcl if tested in December 1992.
A. 6/93 C. 12/94

B. 12/93 D. 6/94 - CORRECT ANSWER- ✔✔B


Find the acid number of a raw material a mole weighing 1.230 g which required 30 ml of
0.1100 N NaOH to bring out the end point using alcoholic KOH in the titration.
A. 150.54 mg/g C. 109.18 mg/g

B. 157.72 mg/g D. 124.41 mg/g - CORRECT ANSWER- ✔✔A


A critical defect that would stop the packaging operation is:
A. Misaligned label C. Smeared label

B. Wrong label D. Inverted label - CORRECT ANSWER- ✔✔B


An instrument use to measure the durability of tablets to shipping/transportation against
shock
and abrasion.
A. Metal detector C. Friabilator

B. Top loading balance D. Colorimeter - CORRECT ANSWER- ✔✔C


Methods of microbial assay of antibiotics:

, A. Turbidimetric C. Both A and B

B. Cylinder plate D. None of the above - CORRECT ANSWER- ✔✔A


Retention or preservation of samples and records of all pharmaceutical products should be
monitored for signs of deterioration. The length of time they should be stored is:
A. 2 years after date of expiration C. 2 years

B. 1 year after date of expiration D. 3 years - CORRECT ANSWER- ✔✔B


Potentiometry finds application in:
A. Biological assay C. Qualitative analysis

B. Identification test D. pH determination - CORRECT ANSWER- ✔✔D


In the assay of sulfonamides, the method used is:
A. Diazotization C. Gravimetric

B. Acid-base titration D. Volumetric - CORRECT ANSWER- ✔✔A


A term in compleximetry used to indicate a determination of a metal in the presence of
another
metal.
A. Linking C. Complexing

B. Masking D. Redox - CORRECT ANSWER- ✔✔B


cGMP is:
A. An agency created by RA 3720
B. Also known as Food, Drug and Cosmetic Act
C. Both A and B are correct

D. Both A and B are incorrect - CORRECT ANSWER- ✔✔D


The sampling and examination of all raw materials received by the factory is a function of
the:

Document information

Uploaded on
September 22, 2024
Number of pages
48
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STANFORDGRADESS
4.0
(240)
Sold
1649
Followers
108
Items
119944
Last sold
1 hour ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions