TFCP FINAL EXAM VERIFIED QUESTIONS AND ANSWERS.

Document preview thumbnail
Preview 3 out of 18 pages

TFCP FINAL EXAM VERIFIED QUESTIONS AND ANSWERS. NFPA 1001 is the Answer-Standard for Firefighter Professional Qualifications One of the primary functions of the truck/ladder company is Answer- performing forcible entry to fire scene buildings OSHA may establish regulations governing fire department activities such as Answer-health and safety In the ICS, the functional area responsible for all incident activities, including the development and implementation of strategic decisions, is Answer-Command What normal body cooling mechanism is lost when wearing PPE? Answer- Evaporation of perspiration What is one aspect of high rise fires that is especially draining of energy? Answer-walking up many flights of stairs in PPE A permits firefighters to gain access during an emergency Answer-key box/lock box In kernmantle rope, the kern or core of the rope accounts for approximately of its strength Answer-75 percent The combination of knots recommended to hoist a pike pole includes Answer-a clove hitch and half hitches The order of rank and authority in the fire service describes Answer-chain of command The street, or address side of the structure is termed Answer-Division A The ratio of the mass of a given volume of liquid compared with the mass of an equal volume of water at the same temperature is Answer-specific gravity Life safety rope should be stored in Answer-coils in rope bags Toxic atmospheres due to smoke and heat are called Answer-immediately dangerous to life and health Which of the following has the highest priority for radio transmission? Answer- Emergency traffic from a unit working at a fire or rescue The telecommunicator's first responsibility is to Answer-obtain the information that is required to dispatch the appropriate units to the correct location Before transmitting any information over the fire department radio, a fire fighter should Answer-listen to be sure the channel is not being used When using positive pressure SCBA, a poor seal between the face piece and the firefighter's face is Answer-dangerous, because it is depleting the air supply more quickly The bypass valve on a SCBA is used Answer-in emergency situations involving a malfunctioning regulator The first noticeable sign of oxygen deficiency is Answer-increased respiratory rate and impaired muscular coordination Four hazardous atmospheres that firefighters are likely to encounter at a fire are Answer-super heated air, toxic gases, oxygen deficiency, and smoke Trapped firefighters awaiting rescue will use less air if they Answer-control their breathing The primary function of the bypass valve on the SCBA is Answer-for use if the regulator fails The proper position of the bypass valve on positive pressure SCBA under normal conditions is Answer-fully closed Hypoxia is Answer-a deficiency of oxygen inhaled toxic gases can directly cause Answer-disease of the lung tissue What is incorrect about the two SCBA types in fire service use? Answer-The closed circuit type is commonly used for structural firefighting

Content preview

TFCP FINAL EXAM 2024-2025 VERIFIED QUESTIONS
AND ANSWERS.

NFPA 1001 is the >> Answer->Standard for Firefighter Professional Qualifications


One of the primary functions of the truck/ladder company is >> Answer->
performing forcible entry to fire scene buildings


OSHA may establish regulations governing fire department activities such as >>
Answer->health and safety


In the ICS, the functional area responsible for all incident activities, including the
development and implementation of strategic decisions, is >> Answer->Command


What normal body cooling mechanism is lost when wearing PPE? >> Answer->
Evaporation of perspiration


What is one aspect of high rise fires that is especially draining of energy? >>
Answer->walking up many flights of stairs in PPE


A permits firefighters to gain access during an emergency >> Answer->key
box/lock box


In kernmantle rope, the kern or core of the rope accounts for approximately
of its strength >> Answer->75 percent


The combination of knots recommended to hoist a pike pole includes >> Answer->a
clove hitch and half hitches

,The order of rank and authority in the fire service describes >> Answer->chain of
command


The street, or address side of the structure is termed >> Answer->Division A


The ratio of the mass of a given volume of liquid compared with the mass of an
equal volume of water at the same temperature is >> Answer->specific gravity


Life safety rope should be stored in >> Answer->coils in rope bags


Toxic atmospheres due to smoke and heat are called >> Answer->immediately
dangerous to life and health


Which of the following has the highest priority for radio transmission? >> Answer->
Emergency traffic from a unit working at a fire or rescue


The telecommunicator's first responsibility is to >> Answer->obtain the information
that is required to dispatch the appropriate units to the correct location


Before transmitting any information over the fire department radio, a fire fighter
should >> Answer->listen to be sure the channel is not being used


When using positive pressure SCBA, a poor seal between the face piece and the
firefighter's face is >> Answer->dangerous, because it is depleting the air supply
more quickly

, The bypass valve on a SCBA is used >> Answer->in emergency situations involving a
malfunctioning regulator


The first noticeable sign of oxygen deficiency is >> Answer->increased respiratory
rate and impaired muscular coordination


Four hazardous atmospheres that firefighters are likely to encounter at a fire are >>
Answer->super heated air, toxic gases, oxygen deficiency, and smoke


Trapped firefighters awaiting rescue will use less air if they >> Answer->control
their breathing


The primary function of the bypass valve on the SCBA is >> Answer->for use if the
regulator fails


The proper position of the bypass valve on positive pressure SCBA under normal
conditions is >> Answer->fully closed


Hypoxia is >> Answer->a deficiency of oxygen


inhaled toxic gases can directly cause >> Answer->disease of the lung tissue


What is incorrect about the two SCBA types in fire service use? >> Answer->The
closed circuit type is commonly used for structural firefighting

Document information

Uploaded on
September 20, 2024
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Nurslink
3.5
(27)
Sold
237
Followers
72
Items
1714
Last sold
17 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions