CDCP Questions and Answers You wish to do a quick estimate of revenue per year. Fill in the missing number. Revenue / [ 8760 ] hours What are the main causes of downtime? Human error Hardware or system failure Previous Play Next Rewind 10 seconds Move forward 10 seconds Unmute 0:06 / 0:15 Full screen Brainpower Read More What is the first and only accredited data centre standard? ANSI/TIA-942 Looking at the ANSI/TIA-942 standard, redundant components based on N+1 is a characteristic of which Rating level? Rating-2 You are evaluating a building to determine the possibility of using it for a data centre. From a technical point of view, what is your preferred floor level in the building to construct your data centre? Top floor Level 1 Which of the below is not a natural hazard? Tunnel The following definition describes which room/area in the data centre: Provides an area where equipment can be acclimated, inspected, configured and safely tested to ensure deployment readiness. Staging area When installing UPS systems in the computer room, what is the keyword to consider? Separation Fuel tanks to support the standby back-up generator need to be installed. Location wise, where do you install the fuel tanks? Regulations depending Which load is applied over the entire area of the floor panel / tile? UDL Using a raised floor, what is the load that rests on the concrete floor in the building? Raised floor frame What is the minimum height of the raised floor? 40 cm (16", 1.3 ft.) A Signal Reference Grid (SRG) provides a [ low impedance path ] for [ high frequency noise currents ] to dissipate before they cause breakdown of equipment [low impedance path ] [ high frequency noise currents ] The recommended unit of measure for light is? Lux Light fixtures should be installed In all aisles Which of the below describes Ohm's Law? P=V*I Electronic, fast switching - is a characteristic of? STS - Static Transfer Switch Current flow through [ ] paths/path, the conductor with the [ ] resistance will carry the [ ] current [ all ] [ lower ] [ most ] To address Common Mode Noise (CMN) an Isolation Transformer is required. Which K-factor do you look for? K-13 W () = VA () [ * ] PF () Watt,Volt Ampere, Power Factor Which of the below statements is correct? THDi creates THDv No need for a controlled environment is a characteristic of which type of UPS? Dynamic UPS You want to purchase a UPS which offers you a maintenance bypass mode. Which UPS technology are you looking for? True Online Double Conversion UPS Which type of battery requires a management system to prevent unsafe temperatures during charging/discharging? Lithium-Ion (Li-ion) In EMF, the IEC 61000-4-8 standard is discussing maximum levels towards Equipment According to the NRCP standard, what maximum EMF exposure levels towards humans? 10 mG Which type of rack provides excellent cooling capabilities? Meshed door based rack Considering light in the data centre, what is the ideal rack colour? White What are the recommended values for equipment inlet temperature? 18 - 27 °C / 64.4 - 80.6 °F Heat that is causing a change of temperature in an object, is considered to be what type of heat? Sensible heat

Content preview

CDCP Questions and Answers
You wish to do a quick estimate of revenue per year. Fill in the missing number. -
answer Revenue / [ 8760 ] hours

What are the main causes of downtime? - answer Human error
Hardware or system failure

What is the first and only accredited data centre standard? - answer ANSI/TIA-942

Looking at the ANSI/TIA-942 standard, redundant components based on N+1 is a
characteristic of which Rating level? - answer Rating-2

You are evaluating a building to determine the possibility of using it for a data centre.
From a technical point of view, what is your preferred floor level in the building to
construct your data centre?
Top floor - answer Level 1

Which of the below is not a natural hazard? - answer Tunnel

The following definition describes which room/area in the data centre: Provides an area
where equipment can be acclimated, inspected, configured and safely tested to ensure
deployment readiness. - answer Staging area

When installing UPS systems in the computer room, what is the keyword to consider? -
answer Separation

Fuel tanks to support the standby back-up generator need to be installed. Location
wise, where do you install the fuel tanks? - answer Regulations depending

Which load is applied over the entire area of the floor panel / tile? - answer UDL

Using a raised floor, what is the load that rests on the concrete floor in the building? -
answer Raised floor frame

What is the minimum height of the raised floor? - answer 40 cm (16", 1.3 ft.)

A Signal Reference Grid (SRG) provides a [ low impedance path ] for [ high frequency
noise currents ] to dissipate before they cause breakdown of equipment - answer
[low impedance path ] [ high frequency noise currents ]

The recommended unit of measure for light is? - answer Lux

Light fixtures should be installed - answer In all aisles

Document information

Uploaded on
September 18, 2024
Number of pages
4
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Pogba119
3.9
(14)
Sold
62
Followers
2
Items
5521
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions