COSC 325 Houston (plumbing) sample questions and solutions |latest updates | GRADED A+ SS - ANSWER Sanitary Sewer ABS - ANSWER Black plastic material VTR - ANSWER vent through roof Primary Purpose of roof vent - ANSWER Let air into system What division is plumbing - ANSWER 22 Invert Depth - ANSWER elevation of the bottom inside of the pipe DW - ANSWER Domestic Water CPVC (chlorinated polyvinyl chloride) - ANSWER hot and cold water supply, off white color FDC - ANSWER Fire Department Connection Above ground pipe material - ANSWER Metal 1 CFH (Cubic Feet per Hour) - ANSWER 1000Btu/h OSHA requirement for fall protection - ANSWER 6 feet OSHA requirement for trenching - ANSWER 5 feet Wall thickness terms for copper - ANSWER Type L, K, M DWV - ANSWER abbreviation for drainage, waste, and vent. Found on "p" sheets What are the four groups of plumbing pipe and fitting material? - ANSWER Plastic, Copper, Cast Iron, Steel What is Expansion loop for? - ANSWER In plastic, provides an area for tubing to expand What plastic pipe is common for DWV? - ANSWER Schedule 40 ABS What is the max length of rigid plastic DWV pipe? - ANSWER 35' What is ABS typically used for? - ANSWER Sanitary drainage, vent, aboveground and underground storm water drainage. What is PVC used for? - ANSWER Sanitary drainage, vent, aboveground and underground storm drainage, water mains, and water service lines. COLD WATER ONLY What is cpvc used for? - ANSWER Typically used for HW and CW distribution, Fire sprinkler pipes, water distribution What is PEX used for? - ANSWER Water service piping, CW and HW systems, used commonly in residential Hangers typically take up ___ of labor cost - ANSWER 20% What is Copper pipe used for? - ANSWER Water supply, fire suppression, HVAC. Fairly rare. What is Cast-Iron no-hub and bell-and-spigot used for? - ANSWER aboveground and underground sanitary drain, vent, and storm water drainage. Bell and spigot typically underground Fittings for plastic piping? - ANSWER Cement, caps, compression fittings Fittings for Copper tubing? - ANSWER Solder joint fittings (Require fire watch), press fitting, Rolled groove joint fitting, threaded Fittings for Cast Iron - ANSWER Hub (Bell-and-Spigot) and no hub Steel piping - ANSWER Galvanised or black Wall thickness terms for plastic - ANSWER Schedule 20, 40, 80, Bigger number=thicker Wall thickness terms for Copper piping - ANSWER Type L, K, M. K is thickest, DWV is thinnest Wall thickness terms for galvanized steel - ANSWER Schedule 40, 80 Angle Valve - ANSWER Globe valve in which the inlet and outlet are at 90 degrees to each other. less resistance to water flow and reduce number of joints required Ball Valve - ANSWER Valve having a ball-shaped internal component with a hole through its center that permits water to flow through when aligned with the waterway. Butterfly Valve - ANSWER Control valve that uses a flat circular plate in a pipe that rotates 90 degrees across the cross section of the pipe to control the flow of water. Check Valve - ANSWER A valve that allows flow in one direction but prevents flow in the opposite direction. Pressure reducing valve - ANSWER A valve which maintains uniform pressure on its outlet side regardless of its pressure fluctuations on the inlet side above the pressure level. Usually installed near meters Water Meter - ANSWER A device used to measure the amount of water that goes through the water service. (Cubic Feet or Gallons) DFU - ANSWER Drainage Fixture Unit. Measure of probable discharge of wastewater and waterborne waste into the drainage system formulated in tests. What is the minimum diameter of building sewer? - ANSWER 4" What is the general slope for a vent? - ANSWER 1/8" per foot Grade/Pitch/Slope for drainage pipe - ANSWER Min of 1/4" per foot, Max of 3" per foot. Underground sewer sometimes not as steep Purpose of a cleanout - ANSWER allow access to the piping to remove stoppages and clean the interior Where should Cleanouts be installed? - ANSWER Front main: at the outside wall of the building at the connection of building sewer and drain Stack base: at the base of all vertical soil or waste stacks all 90 degree changes in direction every 50' on 3" and smaller horizontal drainage pipe; every 100' on 4" and larger horizontal and drainage pipe Stack Vent - ANSWER The extension of a soil or waste stack above the highest horizontal drain connected to the stack. relief vent - ANSWER A vent with a function to provide circulation if air between drainage and vent system. How far should a vent terminal be located from openings? - ANSWER 10' Yoke vent - ANSWER A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of preventing pressure changes in the stack Individual vent - ANSWER A pipe installed to vent, a fixture trap and w/c connects with the vent system above the fixture served or terminates in the open air Common Vent - ANSWER A single vent that ventilates multiple traps in the case of a back to back vent.

Content preview

COSC 325 Houston (plumbing) sample questions and
solutions |latest updates | GRADED A+

SS - ANSWER Sanitary Sewer

ABS - ANSWER Black plastic material

VTR - ANSWER vent through roof

Primary Purpose of roof vent - ANSWER Let air into system

What division is plumbing - ANSWER 22

Invert Depth - ANSWER elevation of the bottom inside of the pipe

DW - ANSWER Domestic Water

CPVC (chlorinated polyvinyl chloride) - ANSWER hot and cold water supply, off white color

FDC - ANSWER Fire Department Connection

Above ground pipe material - ANSWER Metal

1 CFH (Cubic Feet per Hour) - ANSWER 1000Btu/h

OSHA requirement for fall protection - ANSWER 6 feet

OSHA requirement for trenching - ANSWER 5 feet

Wall thickness terms for copper - ANSWER Type L, K, M

DWV - ANSWER abbreviation for drainage, waste, and vent. Found on "p" sheets

What are the four groups of plumbing pipe and fitting material? - ANSWER Plastic, Copper,
Cast Iron, Steel

What is Expansion loop for? - ANSWER In plastic, provides an area for tubing to expand

What plastic pipe is common for DWV? - ANSWER Schedule 40 ABS

What is the max length of rigid plastic DWV pipe? - ANSWER 35'

What is ABS typically used for? - ANSWER Sanitary drainage, vent, aboveground and
underground storm water drainage.

, What is PVC used for? - ANSWER Sanitary drainage, vent, aboveground and underground
storm drainage, water mains, and water service lines. COLD WATER ONLY

What is cpvc used for? - ANSWER Typically used for HW and CW distribution, Fire sprinkler
pipes, water distribution

What is PEX used for? - ANSWER Water service piping, CW and HW systems, used
commonly in residential

Hangers typically take up ___ of labor cost - ANSWER 20%

What is Copper pipe used for? - ANSWER Water supply, fire suppression, HVAC. Fairly rare.

What is Cast-Iron no-hub and bell-and-spigot used for? - ANSWER aboveground and
underground sanitary drain, vent, and storm water drainage. Bell and spigot typically
underground

Fittings for plastic piping? - ANSWER Cement, caps, compression fittings

Fittings for Copper tubing? - ANSWER Solder joint fittings (Require fire watch), press fitting,
Rolled groove joint fitting, threaded

Fittings for Cast Iron - ANSWER Hub (Bell-and-Spigot) and no hub

Steel piping - ANSWER Galvanised or black

Wall thickness terms for plastic - ANSWER Schedule 20, 40, 80, Bigger number=thicker

Wall thickness terms for Copper piping - ANSWER Type L, K, M. K is thickest, DWV is
thinnest

Wall thickness terms for galvanized steel - ANSWER Schedule 40, 80

Angle Valve - ANSWER Globe valve in which the inlet and outlet are at 90 degrees to each
other. less resistance to water flow and reduce number of joints required

Ball Valve - ANSWER Valve having a ball-shaped internal component with a hole through its
center that permits water to flow through when aligned with the waterway.

Butterfly Valve - ANSWER Control valve that uses a flat circular plate in a pipe that rotates 90
degrees across the cross section of the pipe to control the flow of water.

Check Valve - ANSWER A valve that allows flow in one direction but prevents flow in the
opposite direction.

Document information

Uploaded on
September 18, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$9.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro
3.6
(18)
Sold
155
Followers
5
Items
3771
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions