Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Driver Operator Mobile Water Supply

Rating
-
Sold
-
Pages
6
Grade
A+
Uploaded on
13-09-2024
Written in
2024/2025

A hose has a flow rate of 500 gpm with a friction loss of 4 psi, if the flow rate increases to 1000 gpm, then the friction loss will increase to?? - Correct Answer 16 psi A major advantage of a positive displacement pump over a centrifugal pump is that it can? - Correct Answer pump air, making it self priming A MWS apparatus should be started with all electrical switches in the OFF position in order to: - Correct Answer Start engine without a load A single portable water tank works on fires that require? - Correct Answer Relatively low over flow rates(less than 300 gpm) A year has passed and its time conduct the annual vacuum test on your departments MWS apparatus. You're following the procedures for conducting the vacuum test and you've already checked for and removed foreign matter from the hard suction hose. The next step to perform while conducting the vacuum test is to: - Correct Answer Connect 20 Feet of the hard suction hose to the pump intake connection. An important feature of most screw on intake pressure relief valves is that they? - Correct Answer Have bleeder valves to vent air when a connected line is being charged. An MWS apparatus may have steering system problems if the steering wheel can be rotated (without moving front tires) more than: - Correct Answer 10 degrees As hose diameter increases? - Correct Answer Friction loss decreases Before performing a quick fill operation you should make sure the tank vents are open because failure to have adequate venting during this operation could result in? - Correct Answer A dramatic pressure failure of the tank. Before you drive a MWS apparatus across a bridge you should? - Correct Answer compare the weight of the MWS apparatus to the bridges capacity. Both the fill site time and the dump site time include the time spent? - Correct Answer Maneuvering/positioning Braking Distance - Correct Answer Distance a MWS apparatus travels from the time the brakes are applied until the MWS apparatus comes to a complete stop. Centrifugal - Correct Answer Is not self priming Clearance between impeller hub and housing can be a problem Compound gauge - Correct Answer Checks the pump intake pressure Daily inspection - Correct Answer Ensure auxiliary fuel tank is full Operate pump primer Inspect auxiliary winterization system. Direct pumping operation Nurse tanker operation Portable water tank operation - Correct Answer 1. MWS apparatuses pump water from their tanks directly into the fire

Show more Read less
Institution
Driver Operator Mobile Water Supply
Course
Driver Operator Mobile Water Supply

Content preview

Driver Operator Mobile Water Supply
A hose has a flow rate of 500 gpm with a friction loss of 4 psi, if the flow rate increases to 1000 gpm, then the friction
loss will increase to?? - Correct Answer 16 psi

A major advantage of a positive displacement pump over a centrifugal pump is that it can? - Correct Answer pump
air, making it self priming

A MWS apparatus should be started with all electrical switches in the OFF position in order to: - Correct Answer Start
engine without a load

A single portable water tank works on fires that require? - Correct Answer Relatively low over flow rates(less than 300
gpm)

A year has passed and its time conduct the annual vacuum test on your departments MWS apparatus. You're
following the procedures for conducting the vacuum test and you've already checked for and removed foreign matter
from the hard suction hose. The next step to perform while conducting the vacuum test is to: - Correct Answer
Connect 20 Feet of the hard suction hose to the pump intake connection.

An important feature of most screw on intake pressure relief valves is that they? - Correct Answer Have bleeder
valves to vent air when a connected line is being charged.

An MWS apparatus may have steering system problems if the steering wheel can be rotated (without moving front
tires) more than: - Correct Answer 10 degrees

As hose diameter increases? - Correct Answer Friction loss decreases

Before performing a quick fill operation you should make sure the tank vents are open because failure to have
adequate venting during this operation could result in? - Correct Answer A dramatic pressure failure of the tank.

Before you drive a MWS apparatus across a bridge you should? - Correct Answer compare the weight of the MWS
apparatus to the bridges capacity.

Both the fill site time and the dump site time include the time spent? - Correct Answer Maneuvering/positioning

Braking Distance - Correct Answer Distance a MWS apparatus travels from the time the brakes are applied until the
MWS apparatus comes to a complete stop.

Centrifugal - Correct Answer Is not self priming

Clearance between impeller hub and housing can be a problem

Compound gauge - Correct Answer Checks the pump intake pressure

Daily inspection - Correct Answer Ensure auxiliary fuel tank is full

Operate pump primer

Inspect auxiliary winterization system.

Direct pumping operation

Nurse tanker operation

Portable water tank operation - Correct Answer 1. MWS apparatuses pump water from their tanks directly into the fire
pump of the attack apparatus.
2. One MWS apparatus parks next to the attack apparatus supplying it with a discharge line
3. MWS apparatuses dump water into independent tanks and the dump site pumper drafts

, Discharge pressure gauge test - Correct Answer Checks accuracy of discharge readings obtained when pump is in
operation

During MWS apparatus service testing, the atmospheric air temperature should be between: - Correct Answer 0
degree F and 100 degree F

During resupply operation which formula is used to determine the pump discharge pressure? - Correct Answer PDP-
Required Intake Pressure+TPL

Engine speed check - Correct Answer Checks the rate of the engine speed

Filling an MWS apparatus from the top with a portable fill device, or an open hose butt is? - Correct Answer Only
used when an MWS apparatus has no other way of being filled than through a top opening

Flow Meter - Correct Answer Reads the flow of water directly in GPM

Given the flow in GPM, hose length, and hose diameter, you can use a pump chart to determine the? - Correct
Answer

Hard suction hoses generally have a diameter of between? - Correct Answer 4 and 6 inches

Hydrant order...least to greatest - Correct Answer Red, Orange, Green, light blue

Identify FIVE requirements for a MWS apparatus that can be found in NFPA 1901 - Correct Answer 1. An MWS
apparatus equipped with a fire pump must have a tank to pump line at least two inches in diameter and be capable of
supplying the pump with 500 GPM until at least 80% of the tank is emptied.

2. An MWS apparatus must be equipped with at least one external fill connection connected into the tank that allows
the tank to be filled at a minimum rate of 1000 GPM.

3. The external fill connection should be equipped with a valve, strainer, and a 30 degree elbow.

4.Valves that are three inches or larger must be of the slow closing design.

5. An MWS apparatus must have at least three large tank discharges capable of discharging 90% of the tank volume
at an average of 1000 GPM.

Identify FOUR pre-service test for an MWS apparatus equipped with a fire pump? - Correct Answer Road tests

Independent pump certification tests

hydrostatic tests

purchase acceptance tests

Identify the TWO most important reasons for maintaining good MWS apparatus records. - Correct Answer Keeps
everyone on the team informed about equipment conditions.

Helps determine whether equipment should be repaired/replaced.

Identify three conditions that could cause you to lose control of a MWS apparatus? - Correct Answer Liquid surge
within the water tank

traveling a 50 mph around a turn

wet, icy roadways

Identify THREE critical items that should be included on an MWS apparatus daily inspection checklist. - Correct
Answer apparatus unit identification number

inspected by column

Written for

Institution
Driver Operator Mobile Water Supply
Course
Driver Operator Mobile Water Supply

Document information

Uploaded on
September 13, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
chaserdreamer

Get to know the seller

Seller avatar
chaserdreamer EXAMS
View profile
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
1 year
Number of followers
0
Documents
125
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions