Content preview

RESIDENTIAL WIREMAN ELECTRICAL EXAM – LARRY
BOBO |2024 ACTUAL EXAM WITH ACTUAL 250
QUESTIONS AND DETAILED CORRECT VERIFIED
ANSWERS |PRE-ASSESSED A+ |100% GUARANTEED TO
PASS!!




The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase
underground dwelling feeder whose ungrounded conductors have been increased in size from 3
AWG copper to 1 AWG copper is __ AWG copper


Ampacities, Grounding
250.122(B) Table 250.122 Table 8 Ch 9 - ANSWER-4


The continuity of the grounded conductor shall depend on a busbar or __ only.


Continuity, Grounded conductors
200.12 - ANSWER-wire.


Each multi-wire branch circuit shall be provided with a means that will ____ disconnect all
ungrounded conductors at the point where the branch circuit originates.


Disconnecting means, Branch circuits, multiwire 210.4(B) - ANSWER-Simultaneously

,Balconies, decks, and porches that are accessible from the inside of the dwelling unit shall have
at least one receptacle not more than __ ft. above the balcony, deck, or porch surface.
Balconies, outdoor, receptacles for,
210.52(E)(3) - ANSWER-6 1/2


Where it is impracticable to locate the service head above the point of attachment, the service
head location shall be permitted not farther than ___ inches from the point of attachment.
Service drops, Connections, service head
230.54 (C) Exception - ANSWER-24


True/False: One of the means by which grounding conductors and bonding jumpers shall NOT
be connected by is machine screw type fasteners.


Connection of Grounding and Bonding Equipment 250.8 - ANSWER-False


Cables with entirely nonmetallic sheaths are permitted to enter the top of a surface-mounted
enclosure through one or more nonflexible raceways not less than 450 mm (18 in.) and not
more than __ feet in length


Cabinets, Cutout Boxes, and Meter Socket Enclosures. 312.5(C) - ANSWER-10


The maximum allowable overcurrent protection for four 14/2 NM cables installed in contact
with thermal insulation without maintaining spacing between cables is:


Nonmetallic-sheathed cable, Insulation, Ampacity,
334.112, 334.80 - ANSWER-15

, What kind of protection is required for an outdoor receptacle located under the soffit of a
dwelling for holiday lighting?


Ground-fault circuit interrupters, Outdoors, dwelling units,
210.8(A)(3) - ANSWER-GFCI


The minimum rating for a service disconnecting means for a building, other than a single family
dwelling, consisting of three 2 wire circuits shall be__ amperes.


Service equipment, Rating,
230.79(D) - ANSWER-60


Where ungrounded conductors are increased in size, equipment grounding conductors shall be
increased in size ___.


Grounding conductors, 250-III, Sizes, 250.122 250.122(B) - ANSWER-proportionately


True/ False: Unless listed for the control of other loads, general use dimmer switches, shall only
be used to control permanently installed incandescent luminaires.


Dimmers, Switch
404.14(E) - ANSWER-True


In what areas of a dwelling shall 125-volt, single phase, 15 and 20 ampere outlets not be
required to be protected by an arc-fault circuit interupter? Dwellings, Arc-fault circuit-
interrupter protection, 210.12(A) 210.12(A) - ANSWER-Hallways


A ground ring encircling the building or structure, in direct contact with the earth, shall consist
of at least 20 feet of bare copper conductor NOT smaller than __ AWG.

Document information

Uploaded on
September 7, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NurseShanit
5.0
(275)
Sold
19
Followers
8
Items
488
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions