counter fronts and walls? 3 feet (2021 IBC 1208.1)
Whose duty is it to provide access to an means for required inspections? Permit holder (2021
IBC 110.5)
Movable fixtures, cases, counters and partitions are exempt from a building permit where they
have a maximum height of _________ . 5 feet 9 inches (2021 IBC Section 105.2 Building
Item #13)
Unless otherwise mandated by state or local laws, the approved construction documents shall be
retained by the building official for a minimum of ___________ from the date of completion of
the permitted work. 180 days (2021 IBC Section 107.5)
If a cleaning establishment utilizes a liquid solvent having a flash point at or above _________
degrees F, it shall not be considered a high-hazard Group H occupancy but shall be classified as
the occupancy that it most nearly resembles. 200 (2021 IBC Section 307.1.1 Item #5)
The maximum allowable quantity per control area of a Class IC flammable liquid permitted in a
storage condition in a one-story Group F-1 occupancy is _________ gallons if equipped
throughout with an automatic sprinkler system. 240 (2021 IBC Table 307.1(1) Note d)
A proposed building will have a boiler installed within a boiler room that will operate over 15
psi. What is required for this room? 1 hour separation or an automatic sprinkler system (2021
IBC Table 509.1)