AMT 2 Study Guide Exam With Correct
Questions And Answers 2024
Amtrak eConductors eand eEngineer eare eclassified eas eclass e______ eemployees e- ecorrect
eanswer.C. e[1.103]
Should eemployees ein eelectrified eterritory ebe efamiliar ewith ethe elocation eand eoperation eof
eradios eand etelephones? e- ecorrect eanswer.Yes e[1.204]
When eusing erailroad etelephone elines eor eradios, eand eyou ehear ethe eword e"EMERGENCY"
erepeated ethree etimes, ewhat emust ebe edone? e- ecorrect eanswer.All eothers eusing ethe
ephone eline eor eradio echannel emust eyield eimmediately. e[1.205]
All eoccurrences eor econditions ewhich eare elikely eto eaffect eelectric eOperations emust ebe
ereported eimmediately eto ewhom? e- ecorrect eanswer.The ePower eDirector/Train
eDispatcher. e[1.201]
Minimum eApproach eDistance emeans? e- ecorrect eanswer.The edistance ethat emust ebe
emaintained ebetween epersonnel eand eor eequipment eand eall eexposed eenergized elines.
eMinimum eApproach eDistance eis emeasured ebetween ethe eperson eor ethe eend eof ea etool,
eequipment, eor ematerial ebeing eused eand ethe eexposed eenergized eparts. e[1.301]
All eoverhead ewires emust ebe econsidered eenergized e(Live) eat eall etimes eexcept? e- ecorrect
eanswer.When eit eis eknown eto ebe ede-energized, etested ede-energized eand egrounded.
e[1.302]
The ethird erail emust ebe econsidered eenergized e(live) eat eall etimes eexcept? e- ecorrect
eanswer.When eit eis eknown eto ebe ede-energized, etested ede-energized eand ea eThird eRail
eWarning eDevice eis eapplied. e[1.303]
Electric eengines eand eMultiple eUnits e(MU) eunder eoverhead ewires emust ebe econsidered
eenergized e(Live) eexcept? e- ecorrect eanswer.When eit eis eknown ethat eall ePantographs eare
edown eand ePantograph egrounding eswitches eare eclosed, eor eoverhead ewires eare ede-
energized, etested ede-energized eand eproperly egrounded. e[1.501]
Can eemployees etouch eor eremove eunidentified edangling ewires, etrees, eor eforeign eobjects
ein econtact ewith eoverhead ewires eor ethird erail? e- ecorrect eanswer.NO e,employees emust
, etake enecessary eprecautions eto eprotect eothers eand eequipment eand emaintain eMinimum
eApproach eDistance e. e[1.206]
Conductive ematerial esuch eas esteel etape emeasure, ewire, ewet eor enon-rated erope, eor elinen
etape-line econtaining emetallic ereinforcement ecan ebe eused earound eenergized ewire,
eapparatus, eequipment, eor ethird erail. eTrue eor eFalse? e- ecorrect eanswer.False. e[1.114]
The eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees ewhether eor enot
eprotected eby eClass eA eemployee eagainst eTransmission eWires eenergized eor ede-
energized eand enot egrounded eis? e- ecorrect eanswer.8ft. e[Table e1]
What eis ethe eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployee ewhether eor
enot eprotected eby ea eClass eA eemployee eagainst ethe eCatenary, eSignal eLine, eand eUtility
eWires eless ethan e35000 evolts, eenergized eor ede-energized eand enot egrounded? e- ecorrect
eanswer.3ft. e[Table e1]
What eis ethe eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees eagainst
eTransmission eWires efor eequipment eoperating ein ethe evicinity eof ewires eenergized eor ede-
energized eand enot egrounded? e- ecorrect eanswer.15ft. e[Table e1]
The eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees eagainst eCatenary,
eSignal eLine, eUtility eWires eLess ethan e35000 evolts efor eEquipment eoperating ein ethe evicinity
eof ewires eenergized eor ede-energized eand enot egrounded eis/ e- ecorrect eanswer.3ft. e[Table
e1]
Personnel eand eEquipment ebeing eprovided eprotection eby eClass eA eEmployee, ewires ede-
energized, etested ede-energized, eand egrounded ewill ebe eallowed? e- ecorrect eanswer.Full
eContact. e[Table e1]
The eMinimum eApproach eDistance efor eUnidentified eDangling eWires eis? e- ecorrect
eanswer.15ft. e[Table e1]
What eis ethe eMinimum eApproach eDistance ewhile ewalking eover eand earound eenergized
eThird eRail? e- ecorrect eanswer.6 einches. e[Table e2]
what eis ethe eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees eworking ewith
econductive etools eor eequipment earound eThird eRail? e- ecorrect eanswer.4 efeet. e[Table e2]
The eTypical eOverhead eWire eProfile efor ethe eCatenary esystem estarting efrom eThe eWire
ethat econtacts ethe ePantograph eare? e- ecorrect eanswer.Contact ewire, eAuxiliary ewire,
eMessenger ewire, eSignal eline, eTransmission eline, eStatic ewire. e[Figure e9]
What emust ebe edone eprior eto eoperating ein eelectrified eterritory? e- ecorrect eanswer.A ejob
eBriefing. e[1.401]
Questions And Answers 2024
Amtrak eConductors eand eEngineer eare eclassified eas eclass e______ eemployees e- ecorrect
eanswer.C. e[1.103]
Should eemployees ein eelectrified eterritory ebe efamiliar ewith ethe elocation eand eoperation eof
eradios eand etelephones? e- ecorrect eanswer.Yes e[1.204]
When eusing erailroad etelephone elines eor eradios, eand eyou ehear ethe eword e"EMERGENCY"
erepeated ethree etimes, ewhat emust ebe edone? e- ecorrect eanswer.All eothers eusing ethe
ephone eline eor eradio echannel emust eyield eimmediately. e[1.205]
All eoccurrences eor econditions ewhich eare elikely eto eaffect eelectric eOperations emust ebe
ereported eimmediately eto ewhom? e- ecorrect eanswer.The ePower eDirector/Train
eDispatcher. e[1.201]
Minimum eApproach eDistance emeans? e- ecorrect eanswer.The edistance ethat emust ebe
emaintained ebetween epersonnel eand eor eequipment eand eall eexposed eenergized elines.
eMinimum eApproach eDistance eis emeasured ebetween ethe eperson eor ethe eend eof ea etool,
eequipment, eor ematerial ebeing eused eand ethe eexposed eenergized eparts. e[1.301]
All eoverhead ewires emust ebe econsidered eenergized e(Live) eat eall etimes eexcept? e- ecorrect
eanswer.When eit eis eknown eto ebe ede-energized, etested ede-energized eand egrounded.
e[1.302]
The ethird erail emust ebe econsidered eenergized e(live) eat eall etimes eexcept? e- ecorrect
eanswer.When eit eis eknown eto ebe ede-energized, etested ede-energized eand ea eThird eRail
eWarning eDevice eis eapplied. e[1.303]
Electric eengines eand eMultiple eUnits e(MU) eunder eoverhead ewires emust ebe econsidered
eenergized e(Live) eexcept? e- ecorrect eanswer.When eit eis eknown ethat eall ePantographs eare
edown eand ePantograph egrounding eswitches eare eclosed, eor eoverhead ewires eare ede-
energized, etested ede-energized eand eproperly egrounded. e[1.501]
Can eemployees etouch eor eremove eunidentified edangling ewires, etrees, eor eforeign eobjects
ein econtact ewith eoverhead ewires eor ethird erail? e- ecorrect eanswer.NO e,employees emust
, etake enecessary eprecautions eto eprotect eothers eand eequipment eand emaintain eMinimum
eApproach eDistance e. e[1.206]
Conductive ematerial esuch eas esteel etape emeasure, ewire, ewet eor enon-rated erope, eor elinen
etape-line econtaining emetallic ereinforcement ecan ebe eused earound eenergized ewire,
eapparatus, eequipment, eor ethird erail. eTrue eor eFalse? e- ecorrect eanswer.False. e[1.114]
The eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees ewhether eor enot
eprotected eby eClass eA eemployee eagainst eTransmission eWires eenergized eor ede-
energized eand enot egrounded eis? e- ecorrect eanswer.8ft. e[Table e1]
What eis ethe eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployee ewhether eor
enot eprotected eby ea eClass eA eemployee eagainst ethe eCatenary, eSignal eLine, eand eUtility
eWires eless ethan e35000 evolts, eenergized eor ede-energized eand enot egrounded? e- ecorrect
eanswer.3ft. e[Table e1]
What eis ethe eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees eagainst
eTransmission eWires efor eequipment eoperating ein ethe evicinity eof ewires eenergized eor ede-
energized eand enot egrounded? e- ecorrect eanswer.15ft. e[Table e1]
The eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees eagainst eCatenary,
eSignal eLine, eUtility eWires eLess ethan e35000 evolts efor eEquipment eoperating ein ethe evicinity
eof ewires eenergized eor ede-energized eand enot egrounded eis/ e- ecorrect eanswer.3ft. e[Table
e1]
Personnel eand eEquipment ebeing eprovided eprotection eby eClass eA eEmployee, ewires ede-
energized, etested ede-energized, eand egrounded ewill ebe eallowed? e- ecorrect eanswer.Full
eContact. e[Table e1]
The eMinimum eApproach eDistance efor eUnidentified eDangling eWires eis? e- ecorrect
eanswer.15ft. e[Table e1]
What eis ethe eMinimum eApproach eDistance ewhile ewalking eover eand earound eenergized
eThird eRail? e- ecorrect eanswer.6 einches. e[Table e2]
what eis ethe eMinimum eApproach eDistance efor eAMT-2 eQualified eEmployees eworking ewith
econductive etools eor eequipment earound eThird eRail? e- ecorrect eanswer.4 efeet. e[Table e2]
The eTypical eOverhead eWire eProfile efor ethe eCatenary esystem estarting efrom eThe eWire
ethat econtacts ethe ePantograph eare? e- ecorrect eanswer.Contact ewire, eAuxiliary ewire,
eMessenger ewire, eSignal eline, eTransmission eline, eStatic ewire. e[Figure e9]
What emust ebe edone eprior eto eoperating ein eelectrified eterritory? e- ecorrect eanswer.A ejob
eBriefing. e[1.401]