Voice Data Video (VDV) Practice Test Questions with Correct Answers Guaranteed Full Score Download!!! ______ and ________ are the two types of delay measured in a cable test. a. delay skew / NVP b. NVP / return loss c. propagation delay / delay skew d. propagation delay / NVP - Answer -c. propagation delay / delay skew _________ and _________ are the two types of delay measured in a cable test. a. Delay skew/NVP b. NVP/return loss c. Propagation delay/delay skew d. Propagation delay/NVP - Answer -c. Propagation delay/delay skew

Content preview

Voice Data Video (VDV) Practice Test
Questions with Correct Answers
Guaranteed Full Score Download!!!
______ and ________ are the two types of delay measured in a cable test.

a. delay skew / NVP

b. NVP / return loss

c. propagation delay / delay skew

d. propagation delay / NVP

- Answer -c. propagation delay / delay skew



_________ and _________ are the two types of delay measured in a cable test.

a. Delay skew/NVP

b. NVP/return loss

c. Propagation delay/delay skew

d. Propagation delay/NVP

- Answer -c. Propagation delay/delay skew



__________ was devised so that a transmission path can carry many telephone conversations at the
same time.

a. dial tone

b. asynchronous transmission

c. tip/ring

d. multiplexing

- Answer -d. multiplexing



____________ are the most common shock-related injury.

a. Amputations

,b. Broken bones

c. Burns

d. Falls - Answer -c. Burns

"The portion of the wiring system between the load side of the overcurrent device or power-limited
supply and the connected equipment", is the definition of a _______.

a. Class 1 circuit

b. Class 2 circuit

c. Class 3 circuit

d. Circuit Integrity cable

- Answer -a. Class 1 circuit



REF: [NEC] 725.2

10. Installation of equipment that is electrically connected to a communications network shall
__________________________.



a. also include temporary connection of testing equipment for maintenance or repair.

b. be listed as being suitable for electrical connection to a communication network.

c. be listed as being suitable for electrical connection to a communications network including temporary
connection of testing equipment for maintenance orrepair.

d. none of the above

- Answer -b. be listed as being suitable for electrical connection to a communication network.

REF: [NEC] 800.170, 800.18

46. What size outdoor antenna conductor shall be used for a receiving station, where at the maximum
open span length is 150 feet, and the material is hard-drawn copper?

a. 20 AWG

b. 19 AWG

c. 14 AWG

d. 12 AWG

- Answer -c. 14 AWG

REF: [NEC] 810.16(A)

,48. For new construction, a minimum of one communications outlet shall be installed within the
dwelling unit ____________.



a. in the entry way

b. in a common area

c. in a readily accessible area

d. near the service providers point of demarcation

- Answer -c. in a readily accessible area

REF: [NEC] 800.156

A ______ is used to measure optical power.



a. dispersion meter

b. light source

c. power meter

d. volt ohmmeter - Answer -c. power meter

A _______ modular jack contains connection points for two telephone pairs.



a. RJ-11

b. RJ-45

c. T1

d. DTMF - Answer -a. RJ-11

A bonding jumper connected between the radio and television receiving equipment and the power
grounding electrode shall not be smaller than ______.



a. 18 AWG

b. 12 AWG

c. 10 AWG

d. 6 AWG - Answer -d. 6 AWG

REF: [NEC] 810.21(J)

, A bonding jumper not smaller than ______ copper or equivalent shall be connected between the CATV
systems grounding electrode system at the building or structure served where separate electrodes are
used.



a. 12 AWG

b. 10 AWG

c. 8 AWG

d. 6 AWG - Answer -d. 6 AWG

REF: [NEC] 820.100(D)

A cable is required to have a minimum of how many conductors?



a. one

b. two

c. three

d. four - Answer -b. two

REF: [NEC] 800.2

A compression driver is:



a. a seal-tite fitting used on high conduit joints to prevent leakage

b. software used to compress a hard disk

c. the device that produces the high or mid frequency energy that is fed into a horn or other relating
device

d. a subwoofer - Answer -c. the device that produces the high or mid frequency energy that is fed
into a horn or other relating device

A control circuit for a permanent amusement attraction should be supplied from a source that has a
rated output of not more than:



a. 24 volts and 15 amperes

b. 30 volts and 20 amperes

c. 24 volts and 1000 volt-amperes

Document information

Uploaded on
August 28, 2024
Number of pages
61
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
6
Followers
1
Items
1880
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions