Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

Quality Management in the Imaging Sciences 5th Edition By Jeffrey Papp 9780323261999 Chapter 1-15 Complete Guide .

Document preview thumbnail
Preview 2 out of 7 pages

Quality Management in the Imaging Sciences 5th Edition By Jeffrey Papp 9780323261999 Chapter 1-15 Complete Guide .

Content preview

Test Bank For Quality Management in the Imaging Sciences
5th Edition By Jeffrey Papp 9780323261999 Chapter 1-15
Complete Guide .

The greatest enemy of record image detail is:

large focal spot.
part angle.
tube angle.
motion. - ANSWER: motion.

Which device has greater sensitivity to light and provides a higher SNR (signal-to-noise ratio) and
improved contrast resolution?

A TV camera
A charge coupled device
A TV camera and a charge coupled device have equal sensitivity to light, provide equal signal-to-noise
ratio, and equal contrast resolution
None of the above - ANSWER: A charge coupled device

When using an AEC system, what will happen once the predetermined amount of radiation is
transmitted?

The x-ray exposure will continue for approximately .05 seconds
The x-ray exposure will terminate
The image receptor will be overexposed
The image receptor will be underexposed - ANSWER: The x-ray exposure will terminate

Advantages of flat-panel digital fluoroscopy system include:
1. better contrast resolution
2. uniformly distortion-free images
3. high DQE - ANSWER: 1, 2, and 3

The magnitude of the signal differences in the remnant beam that results from the differing
absorption properties of the part describes

quantum noise.
subject contrast.
image contrast.
spatial resolution. - ANSWER: subject contrast.

Which primary exposure technique factor is directly proportionate to the image receptor exposure?

kVp
mAs
SID
Tube filtration - ANSWER: mAs

PSPs must be processed and read soon after exposure because signal loss (image fading) becomes
apparent after approximately

90 minutes.
eight hours.
one week.

, three months. - ANSWER: eight hours.

Which of the following are types of beam restrictors?
I. Cones (cylinder and flare)
II. Collimators
III. Aperture diaphragms - ANSWER: All of the above

With AEC, the area of interest must be placed directly over the selected detectors in order to avoid
which two of the following? (select the two that apply)

A. Overexposure
B. Underexposure
C. Decrease in contrast
D. Increase in contrast - ANSWER: A and B

Select the one incorrect statement below:

A. A primary display workstation is one that is used for image interpretation.

B. The higher/greater the bit depth in digital imaging, the lesser the number of gray shades.

C. Exposure field recognition errors usually occur from scattered radiation outside the VOI area, often
as a result of improper alignment of part, x-ray beam, and IP.

D. Direct digital systems have a fixed spatial resolution that is determined by TFT detector element
(DEL) size. - ANSWER: B. The higher/greater the bit depth in digital imaging, the lesser the number of
gray shades.

When using an AEC system, the backup time should be set at

100% of the expected exposure time
125% of the expected exposure time
150% of the expected exposure time
175% of the expected exposure time - ANSWER: 150% of the expected exposure time

What term is used to describe the numeric value representative of the exposure the IR receives in
digital radiography?

Exposure indicator
Window level
Window width
Pixel value - ANSWER: Exposure indicator

Manipulation of grey level values is associated with

lookup table and window width
window level and lookup table.
window level and edge enhancement.
window width and edge enhancement - ANSWER: lookup table and window width

A wider (increased) window width (select the two that apply)

A. decreases the range of densities
B. increases the image contrast
C. increases the range of densities
D. decreases the image contrast - ANSWER: C and D

Connected book
 image
Jeffrey Papp, PhD, RT(R) (QM) Quality Management in the Imaging Sciences
Publisher: 2014 ISBN: 9780323261999 Edition: Unknown

Document information

Uploaded on
August 22, 2024
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
phinta004
4.7
(182)
Sold
20
Followers
2
Items
982
Last sold
2 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?