• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 29 pages
Exam (elaborations)

NCCT tech in surgery practice exam

Document preview thumbnail
Preview 3 out of 29 pages

NCCT tech in surgery practice exam 1. Laryngospasm during Induction ️ The scrubbed surgical technologist should: prepare for a tracheostomy. 2. Minimum Counts for Cesarean Section ️ The minimum number of counts for a Cesarean section case is: 4. 3. Break in Sterile Technique ️ If the surgical technologist's glove touches the outside of a package, the step to take is: the circulator removes the contaminated glove and then the technologist re-gloves herself. 4. Autoclave Log Review ️ Confirm the documentation of: exposure temperature before using the instrumentation from the autoclave. 5. Minimum Humidity in the OR Suite ️ The minimum percentage level of humidity in the OR suite is: 20%. 6. Items on Preference Card for Myelography ️ A definite item on the preference card for a myelography procedure is: contrast medium. 7. Patient Positioning for Right Total Nephrectomy ️ The patient should be positioned in the: left lateral position. 8. MH Crisis During Surgery ️ In case of a suspected MH crisis, the surgical tech should: prepare to close quickly and maintain the sterile field. 9. Addressing Hematoma Post-Mastectomy ️ If a hematoma develops and the surgeon has left the OR, the surgical technologist should: ask the surgeon to return. 10. Disinfectant for Endotracheal Tube ️ Use Cidex OPA for disinfecting an endotracheal tube used during surgery. 11. Control of Bleeding for Cervical Cone Biopsy ️ Have Monsels solution available for control of bleeding. 12. Checking ESU Generator Before Use ️ The surgical technologist should check for the: biomedical engineering sticker. 13. Emergent Gynecologic Surgery Supplies ️ For an emergent gynecologic procedure, the surgical technologist should have: Poole tip suction and Lap sponges available. 14. Blood Rinsing from Instruments ️ At the end of each case, the surgical technologist should: rinse blood from the instruments with sterile water. 15. Cardiac Arrest and CODE BLUE ️ During a cardiac arrest, the surgical technologist should: prepare internal defibrillator paddles. 16. Bowie-Dick Test Purpose ️ The Bowie-Dick test on an autoclave tests the: amount of air removed from the autoclave. 17. Intraoperative Positioning Injury Prevention ️ To prevent injury to the brachial plexus, place rolled towel padding: beneath the abducted down side arm. 18. Surgical Skin Prep for Right Arm Disarticulation ️ The correct method is to: begin at shoulder to fingertips, including flank and chest, prepping the axilla last, using as many sponges as needed. 19. Instrument for Arteriotomy Extension ️ The instrument used to extend the arteriotomy during a carotid endarterectomy is: Potts-Smith scissors. 20. Retracting Spermatic Cord During Hernia Procedure ️ Provide a moist Penrose to assist with retracting the spermatic cord. 21. Safety Strap Application in Fowler Position ️ The correct application of the safety strap is: 2 inches above the knees.

Content preview

NCCT tech in surgery practice exam


1. Laryngospasm during Induction

✔️ The scrubbed surgical technologist should: prepare for a tracheostomy.



2. Minimum Counts for Cesarean Section

✔️ The minimum number of counts for a Cesarean section case is: 4.



3. Break in Sterile Technique

✔️ If the surgical technologist's glove touches the outside of a package, the step to take is: the
circulator removes the contaminated glove and then the technologist re-gloves herself.



4. Autoclave Log Review

✔️ Confirm the documentation of: exposure temperature before using the instrumentation from the
autoclave.



5. Minimum Humidity in the OR Suite

✔️ The minimum percentage level of humidity in the OR suite is: 20%.



6. Items on Preference Card for Myelography

✔️ A definite item on the preference card for a myelography procedure is: contrast medium.



7. Patient Positioning for Right Total Nephrectomy

✔️ The patient should be positioned in the: left lateral position.



8. MH Crisis During Surgery

✔️ In case of a suspected MH crisis, the surgical tech should: prepare to close quickly and maintain
the sterile field.

,9. Addressing Hematoma Post-Mastectomy

✔️ If a hematoma develops and the surgeon has left the OR, the surgical technologist should: ask the
surgeon to return.



10. Disinfectant for Endotracheal Tube

✔️ Use Cidex OPA for disinfecting an endotracheal tube used during surgery.



11. Control of Bleeding for Cervical Cone Biopsy

✔️ Have Monsels solution available for control of bleeding.



12. Checking ESU Generator Before Use

✔️ The surgical technologist should check for the: biomedical engineering sticker.



13. Emergent Gynecologic Surgery Supplies

✔️ For an emergent gynecologic procedure, the surgical technologist should have: Poole tip suction
and Lap sponges available.



14. Blood Rinsing from Instruments

✔️ At the end of each case, the surgical technologist should: rinse blood from the instruments with
sterile water.



15. Cardiac Arrest and CODE BLUE

✔️ During a cardiac arrest, the surgical technologist should: prepare internal defibrillator paddles.



16. Bowie-Dick Test Purpose

✔️ The Bowie-Dick test on an autoclave tests the: amount of air removed from the autoclave.



17. Intraoperative Positioning Injury Prevention

✔️ To prevent injury to the brachial plexus, place rolled towel padding: beneath the abducted down-
side arm.

, 18. Surgical Skin Prep for Right Arm Disarticulation

✔️ The correct method is to: begin at shoulder to fingertips, including flank and chest, prepping the
axilla last, using as many sponges as needed.



19. Instrument for Arteriotomy Extension

✔️ The instrument used to extend the arteriotomy during a carotid endarterectomy is: Potts-Smith
scissors.



20. Retracting Spermatic Cord During Hernia Procedure

✔️ Provide a moist Penrose to assist with retracting the spermatic cord.



21. Safety Strap Application in Fowler Position

✔️ The correct application of the safety strap is: 2 inches above the knees.



22. Cost-Saving Items for Abdominal Hysterectomy Prep

✔️ To watch costs, the surgical technologist should hold: closing suture, 11 knife blade, extra Raytec.



23. Retractors for Emergent Case on Large Patient

✔️ The surgical technologist will need a: Bookwalter retractor for an emergent case.



24. Sutures for Carotid Endarterectomy

✔️ Anticipate using 7-0 Prolene sutures.



25. Re-scrubbing After Breaking Sterility

✔️ If the surgical technologist breaks sterility, they should: prepare to scrub, re-gown, and re-glove.



26. Monitoring Fluid During Hysteroscopy

✔️ Monitor fluid intake and output to prevent swelling symptoms during a hysteroscopy.

Document information

Uploaded on
August 14, 2024
Number of pages
29
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.29

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
CertifiedGrades
3.9
(38)
Sold
149
Followers
61
Items
8729
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions